CoChat

Structure and Dynamics of Structure Formation in Model Triarm Star Block Copolymers of Polystyrene, Poly(ethylene oxide), and Poly(ε-caprolactone)

Floudas, G., Reiter, G., Lambert, O., Dumas, P. · 1998 · Macromolecules
Cited by 69

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The structure and dynamics of structure formation have been studied in model triarm star block copolymers composed of two crystallizable blocks (poly(ethylene oxide) (PEO) and poly(ε-caprolactone) (PCL)) and one amorphous block (polystyrene (PS)). Crystallization starts from the homogeneous phase. For the structure investigation, X-ray scattering, optical microscopy, and atomic force microscopy have been employed, whereas for the kinetics, we have used differential scanning calorimetry, optical microscopy, and rheology. In the stars, there is a competition for crystallization between the two crystallizable blocks which have similar mobilities and melting temperatures but crystallize in different unit cells (monoclinic vs orthorhombic). When the crystallizable block length ratio is 3 or higher, only the longer block will crystallize. For comparable lengths both blocks can crystallize however, not within the same molecule but the crystallinity, long period, and crystalline lamellar thickness are reduced with respect to the pure PEO and PCL. The latent heats, obtained in the isothermal crystallization calorimetric experiments, are analyzed in terms of the Avrami theory. Although similar Avrami exponents were found for all stars ( n = 2, reflecting a disklike growth from heterogeneous nuclei), the crystallization times were different depending on the nature of the crystallizable blocks. Optical microscopy revealed the formation of different superstructures (spherulites/axialites) depending on the type of crystallizable block (PEO/PCL). The growth rates of these superstructures were obtained and analyzed in terms of a kinetic nucleation theory, and the fold surface free energies were extracted. Notwithstanding the larger specific surface of bulk PCL as compared to that of PEO, the fold surface free energies in the stars were similar to that in PEO, indicating a pure PEO crystal and mixing of the amorphous blocks with the PCL crystal. This is supported from the results of the atomic force microscopy measurements on thin films, which have indicated the formation of perforated PCL crystals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma9806716

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 27

  1. Wunderlich B., 1978, Growth, Annealing
  2. Strobl G., 1996, The Physics of Polymers, 10.1007/978-3-662-03243-5 · DOI · Paper page
  3. Leibler L., 1980, Macromolecules, 13, 1602, 10.1021/ma60078a047 · DOI · Paper page
  4. Floudas G., 1996, Macromolecules, 29, 4142, 10.1021/ma951762v · DOI
  5. Lotz B., 1966, Kolloid Z. Z. Polym., 209, 115, 10.1007/BF01500629 · DOI · Paper page
  6. Lovinger A. J., 1993, J. Polym. Sci., Polym. Phys. Ed., 31, 115, 10.1002/polb.1993.090310201 · DOI
  7. Hamley I. W., 1996, Polymer, 37, 4425, 10.1016/0032-3861(96)00261-3 · DOI
  8. Floudas G., 1997, Macromolecules, 30, 4381, 10.1021/ma9616118 · DOI · Paper page
  9. Perret R., 1972, Makromol. Chem., 162, 147, 10.1002/macp.1972.021620114 · DOI
  10. Gan Z., 1996, J. Appl. Polym. Sci., 59, 961, 10.1002/(SICI)1097-4628(19960207)59:6<961::AID-APP8>3.0.CO;2-N · DOI · Paper page
  11. Lambert O., 1997, Macromol. Rapid Commun., 18, 343, 10.1002/marc.1997.030180411 · DOI · Paper page
  12. Herman J.-J., 1981, Makromol. Chem., 182, 997, 10.1002/macp.1981.021820330 · DOI
  13. Li Y., 1993, Polymer, 34, 9, 10.1016/0032-3861(93)90275-F · doi:10.1016/0032-3861(93)90275-f
  14. Floudas G., 1994, Macromolecules, 27, 7735, 10.1021/ma00104a032 · DOI
  15. Olvera de la Cruz M., 1986, Macromolecules, 19, 2501, 10.1021/ma00164a008 · DOI · Paper page
  16. Tadokoro H., 1964, Makromol. Chem., 73, 109, 10.1002/macp.1964.020730109 · DOI · Paper page
  17. Mezghani K., 1996, Physical Properties of Polymers Handbook
  18. Recent, 1997, Macromolecules, 30, 5804, 10.1021/ma9703923 · DOI
  19. Phillips P. J., 1987, J. Polym. Sci., Polym. Phys. Ed., 25, 1725, 10.1002/polb.1987.090250814 · DOI · Paper page
  20. Avrami M. J., 1939, J. Chem. Phys., 7, 1103, 10.1063/1.1750380 · DOI · Paper page
  21. Goldenfeld N., 1987, J. Cryst. Growth, 84, 601, 10.1016/0022-0248(87)90051-0 · DOI
  22. Reiter G., 1998, Phys. Rev. Lett., 80, 3771, 10.1103/PhysRevLett.80.3771 · DOI · Paper page
  23. Lauritzen J. I., 1960, J. Res. Natl. Bur. Stand., 64, 73, 10.6028/jres.064A.007 · DOI · Paper page
  24. Lovinger A., 1985, J. Polymer, 26, 1595, 10.1016/0032-3861(85)90270-8 · DOI · Paper page
  25. Thomas D. G., 1962, J. Chem. Soc., 4569
  26. Frank C. W., 1996, Science, 273, 912, 10.1126/science.273.5277.912 · DOI · Paper page
  27. Despotopoulou M. M., 1996, Macromolecules, 29, 5797, 10.1021/ma9511964 · DOI · Paper page

Cited by

Metadata

Authors
Floudas, G., Reiter, G., Lambert, O., & Dumas, P.
Venue
Macromolecules
Published
1998-10-01
Volume
31
Issue
21
Pages
7279-7290
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2005539158
Cited by
69
References
4
FWCI
2.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.