The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
A Conducting Polymer Nanojunction Sensor for Glucose Detection
Abstract
This paper presents a glucose sensor using conducting polymer/enzyme nanojunctions and demonstrates that unique features can arise when shrinking a sensor to the nanometer scale. Each nanojunction is formed by bridging a pair of nanoelectrodes separated with a small gap (20−60 nm) with polyaniline/glucose oxidase. The signal transduction mechanism of the sensor is based on the change in the nanojunction conductance as a result of glucose oxidation induced change in the polymer redox state. Due to the small size of the nanojunction sensor, the enzyme is regenerated naturally without the need of redox mediators, which consumes minimal amount of oxygen and at the same time gives very fast response (<200 ms). These features make the nanojunction sensor potentially useful for in vivo detection of glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Hydrogen Sensors and Switches from Electrodeposited Palladium Mesowire Arrays
Favier, F., Walter, E. C., Zach, M. P., Benter, T., & Penner, R. M. (2001) · Science · doi:10.1126/science.1063189 · Cited by 1,385
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
Mao, F., Mano, N., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029510e · Cited by 409
Ofer, D., Crooks, R. M., & Wrighton, M. S. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00178a004 · Cited by 363
Configurations used in the design of screen-printed enzymatic biosensors. A review
Albareda-Sirvent, M., Merkoçi, A., & Alegret, S. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(00)00536-0 · Cited by 325
Raitman, O. A., Katz, E., Bückmann, A. F., & Willner, I. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012680r · Cited by 263
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Graphene Oxide: Intrinsic Peroxidase Catalytic Activity and Its Application to Glucose Detection
Song, Y., Qu, K., Zhao, C., Ren, J., & Qu, X. (2010) · Advanced Materials · doi:10.1002/adma.200903783 · Cited by 2,024
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Recent advances in polyaniline based biosensors
Dhand, C., Das, M., Datta, M., & Malhotra, B. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.017 · Cited by 522
Nanowire‐Based Electrochemical Biosensors
Wanekaya, A. K., Chen, W., Myung, N. V., & Mulchandani, A. (2006) · Electroanalysis · doi:10.1002/elan.200503449 · Cited by 481
Conducting Polyaniline Nanowire and Its Applications in Chemiresistive Sensing
Song, E., & Choi, J.-W. (2013) · Nanomaterials · doi:10.3390/nano3030498 · Cited by 462
Conducting polymer nanostructures and their application in biosensors
Xia, L., Wei, Z., & Wan, M. (2010) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.09.029 · Cited by 402
3D nanostructured conductive polymer hydrogels for high-performance electrochemical devices
Zhao, Y., Liu, B., Pan, L., & Yu, G. (2013) · Energy & Environmental Science · doi:10.1039/c3ee40997j · Cited by 396
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Current Trends in Sensors Based on Conducting Polymer Nanomaterials
Yoon, H. (2013) · Nanomaterials · doi:10.3390/nano3030524 · Cited by 362
Conducting Polymer Nanostructures: Template Synthesis and Applications in Energy Storage
Pan, L., Qiu, H., Dou, C., Li, Y., Pu, L., Xu, J., & Shi, Y. (2010) · International Journal of Molecular Sciences · doi:10.3390/ijms11072636 · Cited by 352
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Wang, Z., Liu, S., Wu, P., & Cai, C. (2009) · Analytical Chemistry · doi:10.1021/ac802421h · Cited by 307
Carbon Nanofiber-Based Glucose Biosensor
Vamvakaki, V., Tsagaraki, K., & Chaniotakis, N. (2006) · Analytical Chemistry · doi:10.1021/ac060551t · Cited by 299
Song, J., Xu, L., Zhou, C., Xing, R., Dai, Q., Liu, D., & Song, H. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am403508f · Cited by 295
Kim, B.-G., Jeong, E. J., Chung, J. W., Seo, S., Koo, B., & Kim, J. (2013) · Nature Materials · doi:10.1038/nmat3595 · Cited by 271
Glucose biosensor based on Au nanoparticles–conductive polyaniline nanocomposite
Xian, Y., Hu, Y., Liu, F., Xian, Y., Wang, H., & Jin, L. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.09.014 · Cited by 260
Gopalan, A. I., Lee, K.-P., Manesh, K. M., Santhosh, P., & Kim, J. H. (2006) · Journal of Molecular Catalysis A: Chemical · doi:10.1016/j.molcata.2006.05.027 · Cited by 57
Metadata
- Authors
- Forzani, E. S., Zhang, H., Nagahara, L. A., Amlani, I., Tsui, R., & Tao, N.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-11
- Volume
- 4
- Issue
- 9
- Pages
- 1785-1788
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2088420689
- Cited by
- 293
- References
- 14
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.