The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Detection beyond the Debye Screening Length in a High-Frequency Nanoelectronic Biosensor
Abstract
Nanosensors based on the unique electronic properties of nanotubes and nanowires offer high sensitivity and have the potential to revolutionize the field of Point-of-Care (POC) medical diagnosis. The direct current (dc) detection of a wide array of organic and inorganic molecules has been demonstrated on these devices. However, sensing mechanism based on measuring changes in dc conductance fails at high background salt concentrations, where the sensitivity of the devices suffers from the ionic screening due to mobile ions present in the solution. Here, we successfully demonstrate that the fundamental ionic screening effect can be mitigated by operating single-walled carbon nanotube field effect transistor as a high-frequency biosensor. The nonlinear mixing between the alternating current excitation field and the molecular dipole field can generate mixing current sensitive to the surface-bound biomolecules. Electrical detection of monolayer streptavidin binding to biotin in 100 mM buffer solution is achieved at a frequency beyond 1 MHz. Theoretical modeling confirms improved sensitivity at high frequency through mitigation of the ionic screening effect. The results should promise a new biosensing platform for POC detection, where biosensors functioning directly in physiologically relevant condition are desired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Hajian, R., Balderston, S., Tran, T., deBoer, T., Etienne, J., Sandhu, M., Wauford, N. A., Chung, J.-Y., Nokes, J., Athaiya, M., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0371-x · Cited by 646
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Ultrasensitive detection of nucleic acids using deformed graphene channel field effect biosensors
Hwang, M. T., Heiranian, M., Kim, Y., You, S., Leem, J., Taqieddin, A., Faramarzi, V., Jing, Y., Park, I., van der Zande, A. M., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15330-9 · Cited by 433
Materials chemistry and engineering in metal halide perovskite lasers
Dong, H., Zhang, C., Liu, X., Yao, J., & Zhao, Y. S. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00598f · Cited by 411
Sensing at the Surface of Graphene Field‐Effect Transistors
Fu, W., Jiang, L., van Geest, E. P., Lima, L. M. C., & Schneider, G. F. (2017) · Advanced Materials · doi:10.1002/adma.201603610 · Cited by 364
Graphene Field‐Effect Transistor and Its Application for Electronic Sensing
Zhan, B., Li, C., Yang, J., Jenkins, G., Huang, W., & Dong, X. (2014) · Small · doi:10.1002/smll.201400463 · Cited by 312
Specific detection of biomolecules in physiological solutions using graphene transistor biosensors
Gao, N., Gao, T., Yang, X., Dai, X., Zhou, W., Zhang, A., & Lieber, C. M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1625010114 · Cited by 274
Progress of new label-free techniques for biosensors: a review
Sang, S., Wang, Y., Feng, Q., Wei, Y., Ji, J., & Zhang, W. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.991270 · Cited by 272
Gao, N., Zhou, W., Jiang, X., Hong, G., Fu, T.-M., & Lieber, C. M. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b00133 · Cited by 268
Kesler, V., Murmann, B., & Soh, H. T. (2020) · ACS Nano · doi:10.1021/acsnano.0c08622 · Cited by 262
Graphene nanoelectronic heterodyne sensor for rapid and sensitive vapour detection
Kulkarni, G. S., Reddy, K., Zhong, Z., & Fan, X. (2014) · Nature Communications · doi:10.1038/ncomms5376 · Cited by 189
Self-citationHuang, W., Besar, K., LeCover, R., Dulloor, P., Sinha, J., Martínez Hardigree, J. F., Pick, C., Swavola, J., Everett, A. D., Frechette, J., et al. (2014) · Chem. Sci. · doi:10.1039/c3sc52638k · Cited by 83
Nanoelectronic Heterodyne Sensor: A New Electronic Sensing Paradigm
Kulkarni, G. S., Zang, W., & Zhong, Z. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00329 · Cited by 32
Self-citation
Metadata
- Authors
- Kulkarni, G. S., & Zhong, Z.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-06
- Volume
- 12
- Issue
- 2
- Pages
- 719-723
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2100289640
- Cited by
- 208
- References
- 4
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.