The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Multifunctional Stable and pH-Responsive Polymer Vesicles Formed by Heterofunctional Triblock Copolymer for Targeted Anticancer Drug Delivery and Ultrasensitive MR Imaging
Abstract
A multifunctional stable and pH-responsive polymer vesicle nanocarrier system was developed for combined tumor-targeted delivery of an anticancer drug and superparamagnetic iron oxide (SPIO) nanoparticles (NPs). These multifunctional polymer vesicles were formed by heterofunctional amphiphilic triblock copolymers, that is, R (folate (FA) or methoxy)-poly(ethylene glycol)(M(w):5000)-poly(glutamate hydrozone doxorubicin)-poly(ethylene glycol) (M(w):2000)-acrylate (i.e., R (FA or methoxy)-PEG(114)-P(Glu-Hyd-DOX)-PEG(46)-acrylate). The amphiphilic triblock copolymers can self-assemble into stable vesicles in aqueous solution. It was found that the long PEG segments were mostly segregated into the outer hydrophilic PEG layers of the vesicles, thereby providing active tumor targeting via FA, while the short PEG segments were mostly segregated into the inner hydrophilic PEG layer of the vesicles, thereby making it possible to cross-link the inner PEG layer via the acrylate groups for enhanced in vivo stability. The therapeutic drug, DOX, was conjugated onto the polyglutamate segment, which formed the hydrophobic membrane of the vesicles using a pH-sensitive hydrazone bond to achieve pH-responsive drug release, while the hydrophilic SPIO NPs were encapsulated into the aqueous core of the stable vesicles, allowing for ultrasensitive magnetic resonance imaging (MRI) detection. The SPIO/DOX-loaded vesicles demonstrated a much higher r(2) relaxivity value than Feridex, a commercially available SPIO-based T(2) contrast agent, which was attributed to the high SPIO NPs loading level and the SPIO clustering effect in the aqueous core of the vesicles. Results from flow cytometry and confocal laser scanning microscopy (CLSM) analysis showed that FA-conjugated vesicles exhibited higher cellular uptake than FA-free vesicles which also led to higher cytotoxicity. Thus, these tumor-targeting multifunctional SPIO/DOX-loaded vesicles will provide excellent in vivo stability, pH-controlled drug release, as well as enhanced MRI contrast, thereby making targeted cancer therapy and diagnosis possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanocarriers as an emerging platform for cancer therapy
Peer, D., Karp, J. M., Hong, S., Farokhzad, O. C., Margalit, R., & Langer, R. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.387 · Cited by 8,710
Multifunctional polymeric micelles as cancer-targeted, MRI-ultrasensitive drug delivery systems
Nasongkla, N., Bey, E., Ren, J., Ai, H., Khemtong, C., Guthi, J. S., Chin, S.-F., Sherry, A. D., Boothman, D. A., & Gao, J. (2006) · Nano Letters · doi:10.1021/nl061412u · Cited by 1,238
Core-cross-linked polymeric micelles as paclitaxel carriers
Shuai, X., Merdan, T., Schaper, A. K., Xi, F., & Kissel, T. (2004) · Bioconjugate Chemistry · doi:10.1021/bc034113u · Cited by 333
Cited by
Wu, W., Wu, Z., Yu, T., Jiang, C., & Kim, W.-S. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/2/023501 · Cited by 1,574
Nicolas, J., Mura, S., Brambilla, D., Mackiewicz, N., & Couvreur, P. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35265f · Cited by 1,270
Ge, Z., & Liu, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60048c · Cited by 914
Theranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Yuan, L., Tang, Q., Yang, D., Zhang, J. Z., Zhang, F., & Hu, J. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp201053d · Cited by 328
Metadata
- Authors
- Yang, X., Grailer, J. J., Rowland, I. J., Javadi, A., Hurley, S. A., Matson, V. Z., Steeber, D. A., & Gong, S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-19
- Volume
- 4
- Issue
- 11
- Pages
- 6805-6817
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2316671269
- Cited by
- 322
- References
- 3
- FWCI
- 10.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.