CoChat

Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Semiconductive nanowire-based biosensors are capable of label-free detection of biological molecules. Nano-FET (field-effect transistor) biosensors exhibiting high sensitivities toward proteins, nucleic acids, and viruses have been demonstrated. Rational device design methodologies, particularly those based on theoretical predictions, were reported. However, few experimental studies have investigated the effect of nanowire diameter, doping density, and number on nano-FET sensitivity. In this study, we devised a fabrication process based on parallel approaches and nanomanipulation-based post-processing for constructing nano-FET biosensor devices with carefully controlled nanowire parameters (diameter, doping density, and number). We experimentally reveal the effect of these nanowire parameters on nano-FET biosensor sensitivity. The experimental findings quantitatively demonstrate that device sensitivity decreases with increasing number of nanowires (4 and 7 nanowire devices exhibited a ∼38 and ∼82% decrease in sensitivity as compared to a single-nanowire device), larger nanowire diameters (sensors with 81-100 and 101-120 nm nanowire diameters exhibited a ∼16 and ∼37% decrease in sensitivity compared to devices with nanowire diameters of 60-80 nm), and higher nanowire doping densities (∼69% decrease in sensitivity due to an increase in nanowire doping density from 10(17) to 10(19) atoms·cm(-3)). These results provide insight into the importance of controlling nanowire propertie…

Overview

Integrity signals

Registry

Crossref · 10.1021/nn202182p

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 44 references

Cited by

Items 101–138 of 138

Metadata

Authors
Li, J., Zhang, Y., To, S., You, L., & Sun, Y.
Affiliations
University of Toronto (CA)
Corresponding author
  • You, Lidan
  • Sun, Yu
Venue
ACS Nano
Published
2011-08-04
Volume
5
Issue
8
Pages
6661-6668
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2022521646
Cited by
138
References
44
Citations by year
2026: 4 · 2025: 9 · 2024: 9 · 2023: 5 · 2022: 9 · 2021: 9 · 2020: 8 · 2019: 10 · 2018: 7 · 2017: 9 · 2016: 15 · 2015: 9 · 2014: 17 · 2013: 8 · 2012: 10
FWCI
6.62
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
biosensor sensitivity, nanowire diameter, doping concentration, label-free detection, nanomanipulation, parallel fabrication, device-to-device variation
MeSH terms
Electric Conductivity, Humans, Immunoglobulin G, Silicon, Transistors, Electronic, Biosensing Techniques, Nanotechnology, Nanowires

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.