Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Semiconductive nanowire-based biosensors are capable of label-free detection of biological molecules. Nano-FET (field-effect transistor) biosensors exhibiting high sensitivities toward proteins, nucleic acids, and viruses have been demonstrated. Rational device design methodologies, particularly those based on theoretical predictions, were reported. However, few experimental studies have investigated the effect of nanowire diameter, doping density, and number on nano-FET sensitivity. In this study, we devised a fabrication process based on parallel approaches and nanomanipulation-based post-processing for constructing nano-FET biosensor devices with carefully controlled nanowire parameters (diameter, doping density, and number). We experimentally reveal the effect of these nanowire parameters on nano-FET biosensor sensitivity. The experimental findings quantitatively demonstrate that device sensitivity decreases with increasing number of nanowires (4 and 7 nanowire devices exhibited a ∼38 and ∼82% decrease in sensitivity as compared to a single-nanowire device), larger nanowire diameters (sensors with 81-100 and 101-120 nm nanowire diameters exhibited a ∼16 and ∼37% decrease in sensitivity compared to devices with nanowire diameters of 60-80 nm), and higher nanowire doping densities (∼69% decrease in sensitivity due to an increase in nanowire doping density from 10(17) to 10(19) atoms·cm(-3)). These results provide insight into the importance of controlling nanowire propertie…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Directed Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-370501-3.x0001-x · Cited by 1,367
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Doping and Electrical Transport in Silicon Nanowires
Cui, Y., Duan, X., Hu, J., & Lieber, C. M. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp0009305 · Cited by 950
Detection of NO2 down to ppb Levels Using Individual and Multiple In2O3 Nanowire Devices
Zhang, D., Liu, Z., Li, C., Tang, T., Liu, X., Han, S., Lei, B., & Zhou, C. (2004) · Nano Letters · doi:10.1021/nl0489283 · Cited by 866
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Analytical Chemistry · doi:10.1021/ac060830g · Cited by 660
Detection Limits for Nanoscale Biosensors
Sheehan, P. E., & Whitman, L. J. (2005) · Nano Letters · doi:10.1021/nl050298x · Cited by 615
Layer-by-Layer Assembly of Nanowires for Three-Dimensional, Multifunctional Electronics
Javey, A., Nam, Friedman, R. S., Yan, H., & Lieber, C. M. (2007) · Nano Letters · doi:10.1021/nl063056l · Cited by 597
Wafer-Scale Assembly of Highly Ordered Semiconductor Nanowire Arrays by Contact Printing
Fan, Z., Ho, J. C., Jacobson, Z. A., Yerushalmi, R., Alley, R. L., Razavi, H., & Javey, A. (2008) · Nano Letters · doi:10.1021/nl071626r · Cited by 582
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
Large-scale assembly of carbon nanotubes
Rao, S. G., Huang, L., Setyawan, W., & Hong, S. (2003) · Nature · doi:10.1038/425036a · Cited by 467
Silicon Nanowire Arrays for Label-Free Detection of DNA
Gao, Z., Agarwal, A., Trigg, A. D., Singh, N., Fang, C., Tung, C.-H., Fan, Y., Buddharaju, K. D., & Kong, J. (2007) · Analytical Chemistry · doi:10.1021/ac061808q · Cited by 430
Carbon nanotube transistors for biosensing applications
Gruner, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3400-4 · Cited by 408
Toward the Development of Printable Nanowire Electronics and Sensors
Fan, Z., Ho, J. C., Takahashi, T., Yerushalmi, R., Takei, K., Ford, A. C., Chueh, Y., & Javey, A. (2009) · Advanced Materials · doi:10.1002/adma.200900860 · Cited by 387
Complementary Detection of Prostate-Specific Antigen Using In2O3 Nanowires and Carbon Nanotubes
Li, C., Curreli, M., Lin, H., Lei, B., Ishikawa, F. N., Datar, R., Cote, R. J., Thompson, M. E., & Zhou, C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053761g · Cited by 378
Diameter-Dependent Electron Mobility of InAs Nanowires
Ford, A. C., Ho, J. C., Chueh, Y.-L., Tseng, Y.-C., Fan, Z., Guo, J., Bokor, J., & Javey, A. (2009) · Nano Letters · doi:10.1021/nl803154m · Cited by 376
ZnO Nanobelt/Nanowire Schottky Diodes Formed by Dielectrophoresis Alignment across Au Electrodes
Lao, C. S., Liu, J., Gao, P., Zhang, L., Davidovic, D., Tummala, R., & Wang, Z. L. (2006) · Nano Letters · doi:10.1021/nl052239p · Cited by 355
Supersensitive, Fast‐Response Nanowire Sensors by Using Schottky Contacts
Hu, Y., Zhou, J., Yeh, P., Li, Z., Wei, T., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.201000278 · Cited by 346
Design Considerations of Silicon Nanowire Biosensors
Nair, P. R., & Alam, M. A. (2007) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2007.909059 · Cited by 316
DNA Sensing by Silicon Nanowire: Charge Layer Distance Dependence
Zhang, G.-J., Zhang, G., Chua, J. H., Chee, R.-E., Wong, E. H., Agarwal, A., Buddharaju, K. D., Singh, N., Gao, Z., & Balasubramanian, N. (2008) · Nano Letters · doi:10.1021/nl072991l · Cited by 278
Surface Charge Sensitivity of Silicon Nanowires: Size Dependence
Elfström, N., Juhasz, R., Sychugov, I., Engfeldt, T., Karlström, A. E., & Linnros, J. (2007) · Nano Letters · doi:10.1021/nl0709017 · Cited by 275
Screening-Limited Response of NanoBiosensors
Nair, P. R., & Alam, M. A. (2008) · Nano Letters · doi:10.1021/nl072593i · Cited by 227
Lee, M., Im, J., Lee, B. Y., Myung, S., Kang, J., Huang, L., Kwon, Y.-K., & Hong, S. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.46 · Cited by 202
Precise Semiconductor Nanowire Placement Through Dielectrophoresis
Raychaudhuri, S., Dayeh, S. A., Wang, D., & Yu, E. T. (2009) · Nano Letters · doi:10.1021/nl900423g · Cited by 196
Self-aligned self assembly of multi-nanowire silicon field effect transistors
Black, C. T. (2005) · Applied Physics Letters · doi:10.1063/1.2112191 · Cited by 190
Silicon Nanoribbons for Electrical Detection of Biomolecules
Elfström, N., Karlström, A. E., & Linnros, J. (2008) · Nano Letters · doi:10.1021/nl080094r · Cited by 185
Difference in formation of hydrogen and helium clusters in tungsten
Henriksson, K. O. E., Nordlund, K., Krasheninnikov, A., & Keinonen, J. (2005) · Applied Physics Letters · doi:10.1063/1.2103390 · Cited by 175
Carbon nanotube biosensors: The critical role of the reference electrode
Minot, E. D., Janssens, A. M., Heller, I., Heering, H. A., Dekker, C., & Lemay, S. G. (2007) · Applied Physics Letters · doi:10.1063/1.2775090 · Cited by 148
Silicon nanowires for sequence-specific DNA sensing: device fabrication and simulation
Li, Z., Rajendran, B., Kamins, T. I., Li, X., Chen, Y., & Williams, R. S. (2005) · Applied Physics A · doi:10.1007/s00339-004-3157-1 · Cited by 137
Heo, K., Cho, E., Yang, J.-E., Kim, M.-H., Lee, M., Lee, B. Y., Kwon, S. G., Lee, M.-S., Jo, M., Choi, H., et al. (2008) · Nano Letters · doi:10.1021/nl802570m · Cited by 136
Chemical sensing with ZnO nanowire field-effect transistor
Fan, Z., & Lu, J. G. (2006) · IEEE Transactions On Nanotechnology · doi:10.1109/tnano.2006.877428 · Cited by 106
Optimizing the Signal-to-Noise Ratio for Biosensing with Carbon Nanotube Transistors
Heller, I., Männik, J., Lemay, S. G., & Dekker, C. (2009) · Nano Letters · doi:10.1021/nl8031636 · Cited by 86
Numerical Characterization and Optimization of the Microfluidics for Nanowire Biosensors
Kim, D. R., & Zheng, X. (2008) · Nano Letters · doi:10.1021/nl801559m · Cited by 70
Label-free Electronic Detection of the Antigen-Specific T-Cell Immune Response
Stern, E., Steenblock, E. R., Reed, M. A., & Fahmy, T. M. (2008) · Nano Letters · doi:10.1021/nl801693k · Cited by 70
STERN, E. W., Vacic, A., Li, C., Ishikawa, F. N., Zhou, C., Reed, M. A., & Fahmy, T. M. (2009) · Small · doi:10.1002/smll.200901551 · Cited by 58
Probing the sensitivity of nanowire-based biosensors using liquid-gating
Lu, M.-P., Hsiao, C.-Y., Lai, W.-T., & Yang, Y. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/42/425505 · Cited by 39
The influence of Ga+irradiation on the transport properties of mesoscopic conducting thin films
Barzola-Quiquia, J. L., Dusari, S., Bridoux, G., Bern, F., Molle, A., & Esquinazi, P. D. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/14/145306 · Cited by 19
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Kim, H. J., Choi, K., Baek, Y., Kim, D.-G., Shim, J., Yoon, J., & Lee, J.-C. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am405398f · Cited by 303
Metal oxide modified ZnO nanomaterials for biosensor applications
Tripathy, N., & Kim, D.-H. (2018) · Nano Convergence · doi:10.1186/s40580-018-0159-9 · Cited by 200
Recent advances in nanorobotic manipulation inside scanning electron microscopes
Shi, C., Luu, D. K., Yang, Q., Liu, J., Chen, J., Ru, C., Xie, S., Luo, J., Ge, J., & Sun, Y. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.24 · Cited by 191
Self-citation
Metadata
- Authors
- Li, J., Zhang, Y., To, S., You, L., & Sun, Y.
- Affiliations
- University of Toronto (CA)
- Corresponding author
- You, Lidan
- Sun, Yu
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-04
- Volume
- 5
- Issue
- 8
- Pages
- 6661-6668
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2022521646
- Cited by
- 138
- References
- 44
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 9 · 2023: 5 · 2022: 9 · 2021: 9 · 2020: 8 · 2019: 10 · 2018: 7 · 2017: 9 · 2016: 15 · 2015: 9 · 2014: 17 · 2013: 8 · 2012: 10
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- biosensor sensitivity, nanowire diameter, doping concentration, label-free detection, nanomanipulation, parallel fabrication, device-to-device variation
- MeSH terms
- Electric Conductivity, Humans, Immunoglobulin G, Silicon, Transistors, Electronic, Biosensing Techniques, Nanotechnology, Nanowires
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.