A Simple and Widely Applicable Method to 59Fe-Radiolabel Monodisperse Superparamagnetic Iron Oxide Nanoparticles for In Vivo Quantification Studies
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A simple, fast, efficient, and widely applicable method to radiolabel the cores of monodisperse superparamagnetic iron oxide nanoparticles (SPIOs) with (59)Fe was developed. These cores can be used as precursors for a variety of functionalized nanodevices. A quality control using filtration techniques, size-exclusion chromatography, chemical degradation methods, transmission electron microscopy, and magnetic resonance imaging showed that the nanoparticles were stably labeled with (59)Fe. Furthermore, the particle structure and the magnetic properties of the SPIOs were unchanged. In a second approach, monodisperse SPIOs stabilized with (14)C-oleic acid were synthesized, and the stability of this shell labeling was studied. In proof of principle experiments, the (59)Fe-SPIOs coated with different shells to make them water-soluble were used to evaluate and compare in vivo pharmacokinetic parameters such as blood half-life. It could also be shown that our radiolabeled SPIOs embedded in recombinant lipoproteins can be used to quantify physiological processes in closer detail than hitherto possible. In vitro and in vivo experiments showed that the (59)Fe label is stable enough to be applied in vivo, whereas the (14)C label is rapidly removed from the iron core and is not adequate for in vivo studies. To obtain meaningful results in in vivo experiments, only (59)Fe-labeled SPIOs should be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Longmire, M., Choyke, P. L., & Kobayashi, H. (2008) · Nanomedicine · doi:10.2217/17435889.3.5.703 · Cited by 2,149
Brown adipose tissue activity controls triglyceride clearance
Bartelt, A., Bruns, O. T., Reimer, R., Hohenberg, H., Ittrich, H., Peldschus, K., Kaul, M. G., Tromsdorf, U. I., Weller, H., Waurisch, C., et al. (2011) · Nature Medicine · doi:10.1038/nm.2297 · Cited by 1,608
Self-citation
Cited by
Iron Oxide Based Nanoparticles for Multimodal Imaging and Magnetoresponsive Therapy
Lee, N., Yoo, D., Ling, D., Cho, M. H., Hyeon, T., & Cheon, J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00112 · Cited by 1,005
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Exceedingly small iron oxide nanoparticles as positive MRI contrast agents
Wei, H., Bruns, O. T., Kaul, M. G., Hansen, E. C., Barch, M., Wiśniowska, A., Chen, O., Chen, Y., Li, N., Okada, S., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1620145114 · Cited by 489
Self-citationIn vivo degeneration and the fate of inorganic nanoparticles
Feliu, N., Docter, D., Heine, M., del Pino, P., Ashraf, S., Kolosnjaj-Tabi, J., Macchiarini, P., Nielsen, P., Alloyeau, D., Gazeau, F., et al. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00699f · Cited by 423
Self-citationKandasamy, G., & Maity, D. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.10.058 · Cited by 422
Metadata
- Authors
- Freund, B., Tromsdorf, U. I., Bruns, O. T., Heine, M., Giemsa, A., Bartelt, A., Salmen, S. C., Raabe, N., Heeren, J., Ittrich, H., Reimer, R., Hohenberg, H., Schumacher, U., Weller, H., & Nielsen, P.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-07-20
- Volume
- 6
- Issue
- 8
- Pages
- 7318-7325
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2316973802
- Cited by
- 86
- References
- 2
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.