The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Gold Nanorods for Ovarian Cancer Detection with Photoacoustic Imaging and Resection Guidance via Raman Imaging in Living Mice
Open accessAbstract
Improved imaging approaches are needed for ovarian cancer screening, diagnosis, staging, and resection guidance. Here, we propose a combined photoacoustic (PA)/Raman approach using gold nanorods (GNRs) as a passively targeted molecular imaging agent. GNRs with three different aspect ratios were studied. Those with an aspect ratio of 3.5 were selected for their highest ex vivo and in vivo PA signal and used to image subcutaneous xenografts of the 2008, HEY, and SKOV3 ovarian cancer cell lines in living mice. Maximum PA signal was observed within 3 h for all three lines tested and increased signal persisted for at least two days postadministration. There was a linear relationship (R(2) = 0.95) between the PA signal and the concentration of injected molecular imaging agent with a calculated limit of detection of 0.40 nM GNRs in the 2008 cell line. The same molecular imaging agent could be used for clear visualization of the margin between tumor and normal tissue and tumor debulking via surface-enhanced Raman spectroscopy (SERS) imaging. Finally, we validated the imaging findings with biodistribution data and elemental analysis. To the best of our knowledge, this is the first report of in vivo imaging of ovarian cancer tumors with a photoacoustic and Raman imaging agent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
The Fate and Toxicity of Raman-Active Silica-Gold Nanoparticles in Mice
Thakor, A. S., Luong, R., Paulmurugan, R., Lin, F. I., Kempen, P., Zavaleta, C., Chu, P., Massoud, T. F., Sinclair, R., & Gambhir, S. S. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001963 · Cited by 159
Self-citationRaman's “Effect” on Molecular Imaging
Zavaleta, C. L., Kircher, M. F., & Gambhir, S. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.087775 · Cited by 88
Self-citation
Cited by
Surface plasmon resonance in gold nanoparticles: a review
Amendola, V., Pilot, R., Frasconi, M., Maragò, O. M., & Iatì, M. A. (2017) · Journal of Physics: Condensed Matter · doi:10.1088/1361-648x/aa60f3 · Cited by 1,905
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Photoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
Self-citationMiao, Q., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201801778 · Cited by 537
Shi, D., Beasock, D., Fessler, A., Szebeni, J., Ljubimova, J. Y., Afonin, K. A., & Dobrovolskaia, M. A. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.114079 · Cited by 535
Metadata
- Authors
- Jokerst, J. V., Cole, A. J., Van de Sompel, D., & Gambhir, S. S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-11-02
- Volume
- 6
- Issue
- 11
- Pages
- 10366-10377
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1970412285
- Cited by
- 397
- References
- 4
- FWCI
- 19.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.