CoChat

Giant Tunneling Piezoresistance of Composite Elastomers with Interlocked Microdome Arrays for Ultrasensitive and Multimodal Electronic Skins

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

The development of flexible electronic skins with high sensitivities and multimodal sensing capabilities is of great interest for applications ranging from human healthcare monitoring to robotic skins to prosthetic limbs. Although piezoresistive composite elastomers have shown great promise in this area of research, typically poor sensitivities and low response times, as well as signal drifts with temperature, have prevented further development of these materials in electronic skin applications. Here, we introduce and demonstrate a design of flexible electronic skins based on composite elastomer films that contain interlocked microdome arrays and display giant tunneling piezoresistance. Our design substantially increases the change in contact area upon loading and enables an extreme resistance-switching behavior (ROFF/RON of ∼105). This translates into high sensitivity to pressure (−15.1 kPa–1, ∼0.2 Pa minimum detection) and rapid response/relaxation times (∼0.04 s), with a minimal dependence on temperature variation. We show that our sensors can sensitively monitor human breathing flows and voice vibrations, highlighting their potential use in wearable human-health monitoring systems.

Overview

Integrity signals

Registry

Crossref · 10.1021/nn500441k

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 39 references

Research works printed but not linked: 1

  1. Nolan, 2009, Accelerometer Based Measurement for the Mapping of Neck Surface Vibrations during Vocalized Speech, Annu. Int. Conf. IEEE, 4453

Cited by

Items 801–900 of 916

Metadata

Authors
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H.
Affiliations
  • Ulsan Metropolitan City (KR)
  • Ulsan National Institute of Science and Technology (KR)
  • Korea Institute of Machinery & Materials (KR)
Corresponding author
Ko, Hyunhyub
Venue
ACS Nano
Published
2014-03-04
Volume
8
Issue
5
Pages
4689-4697
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2323734260
Cited by
915
References
39
Citations by year
2026: 50 · 2025: 65 · 2024: 79 · 2023: 86 · 2022: 104 · 2021: 102 · 2020: 125 · 2019: 103 · 2018: 75 · 2017: 48 · 2016: 36 · 2015: 34 · 2014: 8
FWCI
21.82
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
  • Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
electronic skin, piezoresistive sensors, rubber composites, pressure sensing, resistive switching, flexible electronics, multimodal sensing, respiratory monitoring, wearable health monitoring, temperature drift
MeSH terms
Artificial Limbs, Electrochemistry, Electronics, Humans, Materials Testing, Monitoring, Physiologic, Pressure, Prosthesis Design, Robotics, Skin, Reproducibility of Results, Finite Element Analysis, Elastomers, Nanotechnology, Nanotubes, Carbon

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.