Evaluation of the Effect of Trypsin Digestion Buffers on Artificial Deamidation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Nonenzymatic deamidation occurs readily under the condition of trypsin digestion, resulting in the identification of many artificial deamidation sites. To evaluate the effect of trypsin digestion buffers on artificial deamidation, we compared the three commonly used buffers Tris-HCl (pH 8), ammonium bicarbonate (ABC), and triethylammonium bicarbonate (TEAB), and ammonium acetate (pH 6), which was reported to reduce Asn deamidation. iTRAQ quantification on rat kidney tissue digested in these four buffers indicates that artificial Asn deamidation is produced in the order of ammonium acetate < Tris-HCl < ABC < TEAB, and Gln deamidation has no significant differences in all tested buffers. Label-free experiments show the same trend, while protein and unique peptide identification are comparable using these four buffers. To explain the differences of these four buffers in producing artificial Asn deamidation, we determined the half-life of Asn deamidation in these buffers using synthetic peptides containing -Asn-Gly- sequences. It is 51.4 ± 6.0 days in 50 mM of ammonium acetate (pH 6) at 37 °C, which is about 23, 104, and 137 times that in Tris-HCl, ABC, and TEAB buffers, respectively. In conclusion, ammonium acetate (pH 6) is more suitable than other tested buffers for characterizing endogenous deamidation and N-glycosylation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Roher, A. E., Lowenson, J. D., Clarke, S., Wolkow, C., Wang, R., Cotter, R. J., Reardon, I. M., Zürcher-Neely, H. A., Heinrikson, R. L., & Ball, M. J. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)53661-9 · Cited by 799
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450 · cited 2×
“The collected fractions were then dried with vacuum centrifuge, pooled into 6 fractions by combining (1-3); (4-5); (6-7); (8-9); (10-11); (12-16), and redissolved in 3% ACN/0.”
MethodOptimization of Mass Spectrometry-Compatible Surfactants for Shotgun Proteomics
Chen, E. I., Cociorva, D., Norris, J. L., & Yates, J. R. (2007) · Journal of Proteome Research · doi:10.1021/pr060682a · Cited by 218 · cited 2×
“The collected fractions were then dried with vacuum centrifuge, pooled into 6 fractions by combining (1-3); (4-5); (6-7); (8-9); (10-11); (12-16), and redissolved in 3% ACN/0.”
Method
Cited by
Minimizing Laboratory-Induced Decay in Bone Proteomics
Procopio, N., & Buckley, M. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00564 · Cited by 61
Graf, T., Heinrich, K., Grunert, I., Wegele, H., Haberger, M., Bulau, P., & Leiss, M. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113251 · Cited by 46
Dominguez-Vega, E., De Vijlder, T., Romijn, E. P., & Somsen, G. W. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.06.021 · Cited by 19
Metadata
- Authors
- Hao, P., Ren, Y., Datta, A., Tam, J. P., & Sze, S. K.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-22
- Volume
- 14
- Issue
- 2
- Pages
- 1308-1314
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W1984336508
- Cited by
- 60
- References
- 4
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the Effect of Trypsin Digestion Buffers on Artificial Deamidation. https://app.cochat.ai/papers/10.1021/pr500903b
- The paper
- Hao, P., Ren, Y., Datta, A., Tam, J. P., & Sze, S. K. (2015). Evaluation of the Effect of Trypsin Digestion Buffers on Artificial Deamidation. Journal of Proteome Research. https://doi.org/10.1021/pr500903b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.