The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Abstract
The importance of glucose monitoring for in vivo as well as for ex vivo applications has driven a vast number of scientific groups to pursue the development of an advanced glucose sensor. Such a sensor must be robust, versatile, and capable of the long-term, accurate and reproducible detection of glucose levels in various testing media. Among the different configurations and signal transduction mechanisms used, fluorescence-based glucose sensors constitute a growing class of glucose sensors represented by an increasing number of significant contributions to the field over the last few years. This manuscript reviews the progress in the development of fluorescence based glucose sensors resulting from the advances in the design of new receptor systems for glucose recognition and the utilization of new fluorescence transduction schemes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Photobleaching of the fluorophore and scattering in tissue are significant drawbacks.19,35–36”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [35]
In the citing paper
“While optical detection provides sensitive detection without damaging the host, skin pigmentation and epidermal thickness can negatively impact the analytical response among hosts.35–36”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [35]
Citations
Cites
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12 · Cited by 765
James, T. D., Sandanayake, K. R. A. S., Iguchi, R., & Shinkai, S. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00140a013 · Cited by 486
Yoon, J., & Czarnik, A. W. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00040a067 · Cited by 476
Plant lectins: Occurrence, biochemistry, functions and applications
Rüdiger, H. E. F., & Gabius, H. (2001) · Glycoconjugate Journal · doi:10.1023/a:1020687518999 · Cited by 460
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 369
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 354
Imaging of the Dynamics of Glucose Uptake in the Cytosol of COS-7 Cells by Fluorescent Nanosensors
Fehr, M., Lalonde, S., Lager, I., Wolff, M. W., & Frommer, W. B. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m301333200 · Cited by 302
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Eggert, H., Frederiksen, J., Morin, C., & Norrild, J. C. (1999) · The Journal of Organic Chemistry · doi:10.1021/jo9819279 · Cited by 260
Research works printed but not linked: 1
- H. M. Heise (2000). In R. A. Meyers (Ed.), Encyclopedia of Analytical Chemistry: Instrumentation and Applications, Wiley, Chichester, U. K. Vol. I, 56–83.
Cited by
Sorted by citations
Items 101–154 of 154
Shariki, S., Cox, O. T. L., Tickell, D. A., Morais, M. P. P., van den Elsen, J. M. H., James, T. D., Dale, S. E. C., Bending, S. J., & Marken, F. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm31089a · Cited by 8
Su, C., Chen, C., Tseng, P., & Sun, Y. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.091 · Cited by 8
Towards a FRET-based immunosensor for continuous carbohydrate monitoring
Engström, H. A., Andersson, P. O., Gregorius, K., & Ohlson, S. (2008) · Journal of Immunological Methods · doi:10.1016/j.jim.2008.01.021 · Cited by 8
Glucose detection at attomole levels using dynamic light scattering and gold nanoparticles
Miao, X., Feng, Z., Tian, J., & Peng, X. (2014) · Science China Chemistry · doi:10.1007/s11426-014-5079-x · Cited by 8
Modeling on the Feasibility of Camera-Based Blood Glucose Measurement
Wang, Y., Wang, W., van Gastel, M., & de Haan, G. (2019) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2019.00212 · Cited by 8
Fluorescence-Based Glucose Biosensors
Coté, G. L., McShane, M. J., & Shih, W. (2008) · Series in medical physics and biomedical engineering · doi:10.1201/9781584889755.ch11 · Cited by 8
Tarasov, Y. V., Philippov, Y. I., Борисова, Е. А., Fedorova, E. A., Mayorov, A. Y., & Shestakova, M. V. (2015) · Problems of Endocrinology · doi:10.14341/probl201561454-72 · Cited by 7
Ethynylated Triphenylamine Monoboronic acid Chemosensors: Experimental and Theoretical Studies
Chi, L., Wu, Y., Zhang, X., Ji, S., Shao, J., Guo, H., Wang, X., & Zhao, J. (2010) · Journal of Fluorescence · doi:10.1007/s10895-010-0677-2 · Cited by 7
Overviews the methods of non-invasive blood glucose measurement
Liu, Y., Li, W., Zheng, T., & Ling, B. W. (2016) · IEEE International Conference on Consumer Electronics - China (ICCE-China) · doi:10.1109/icce-china.2016.7849756 · Cited by 7
Nguyen, T., Tathireddy, P., & Magda, J. J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2883986 · Cited by 7
Simultaneous Determination of Glucose and Choline Based on the Intrinsic Fluorescence of the Enzymes
Sanz-Vicente, I., Romero, J., de Marcos, S., Ostra, M., Ubide, C., & Galbán, J. (2008) · Journal of Fluorescence · doi:10.1007/s10895-008-0448-5 · Cited by 7
McGregor, N. G. S., Pardin, C., & Skene, W. G. (2011) · Australian Journal of Chemistry · doi:10.1071/ch11297 · Cited by 7
Carbon dots as an effective material in enzyme immobilization for sensing applications
Keerthana, P., Cherian, A. R., & Varghese, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-98350-1.00006-2 · Cited by 6
A nanosensor for determination of glucose based on silver nanoparticles as fluorescence probes
Tashkhourian, J., Akhond, M., Hooshmand, S., & Afsharinejad, M. (2015) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-015-0677-x · Cited by 6
Boronic Acid Based Modular Fluorescent Saccharide Sensors
Fossey, J., & James, T. D. (2009) · Reviews in fluorescence · doi:10.1007/978-0-387-88722-7_5 · Cited by 6
A Non-invasive Way Of Diagnosing Diabetes Based On The Heart Beat Rate
Padmini, J. J., Kavya, R., Ilakkiya, B., Gurupriya, R., & Monika, P. (2020) · International Conference on Inventive Systems and Control (ICISC) · doi:10.1109/icisc47916.2020.9171216 · Cited by 5
Microfluidic platform with absorbance sensor for glucose detection
Flores, G., Perdigones, F., Aracil, C., Cabello, M., & Quero, J. M. (2015) · Spanish Conference on Electron Devices · doi:10.1109/cde.2015.7087493 · Cited by 5
Fluorescence‐Based Glucose Sensors
McShane, M. J., & Stein, E. W. (2009) · doi:10.1002/9780470567319.ch10 · Cited by 5
3D-Printed Microfluidic Sensor for Fluorescence Measurements
Nawrot, W., Gzubicka, W., & Malecha, K. (2020) · Periodica Polytechnica Electrical Engineering and Computer Science · doi:10.3311/ppee.15362 · Cited by 4
Liu, W., Huang, A., & Wang, P. (2017) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm.2017.8217690 · Cited by 4
Single‐Walled Carbon Nanotube Near‐Infrared Fluorescent Sensors for Biological Systems
Zhang, J., & Strano, M. S. (2011) · Wiley eBooks · doi:10.1002/9780470767047.ch10 · Cited by 4
Gaussian probe beam with high spherical aberration for glucose concentration measurement
Yáñez, E., Cywiak, M., & Franco, S. J. M. (2018) · Applied Optics · doi:10.1364/ao.57.004153 · Cited by 3
Yáñez, E., Cywiak, M., Juan Manuel Franco, S., & Cywiak, D. (2019) · Applied Optics · doi:10.1364/ao.58.008495 · Cited by 3
Stepanenko, O. V., Stepanenko, O. V., Fonin, A. V., Verkhusha, V. V., Kuznetsova, I. М., & Константинович, Т. К. (2012) · Journal of Spectroscopy · doi:10.1155/2012/169579 · Cited by 2
Thomas, C., Roska, R. W., & Carlson, R. E. (2012) · Springer series on chemical sensors and biosensors · doi:10.1007/5346_2012_23 · Cited by 2
Ren, Z., Liu, G., Xiong, Z., & Huang, Z. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2185787 · Cited by 2
An Assessment of Pain-Free Blood Glucose Level by Noninvasive Methods
Agalya, V., & Sumathi, S. (2021) · International Journal of Current Research and Review · doi:10.31782/ijcrr.2021.13501 · Cited by 2
AL-Khafaji, R. D. M., Pusppanathan, J., Moolla, A., & Phang, F. A. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-97578-3_8 · Cited by 1
Gao, X., Hang, Y., Boryczka, J., Tan, W., Zheng, P., Yang, F., Engler-Chiurazzi, E. B., Simpkins, J. W., & Wu, N. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117903 · Cited by 1
Genetically Engineered Proteins as Recognition Receptors
Dattelbaum, J. D. (2009) · Springer eBooks · doi:10.1007/978-1-4419-0919-0_13 · Cited by 1
Claps, R., & Virojanapa, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.11.117001 · Cited by 1
Datta, S. (2010) · CRC Press eBooks · doi:10.1201/b10450-9 · Cited by 1
A Critical Review on Current Devloping Non-Invasive Glucose Monitoring Technologies and Devices
Patel, A. I., Rachhadiya, J., Vadariya, P., Vysh, A. J., & Patel, A. B. (2022) · Asian Journal of Pharmaceutical Analysis · doi:10.52711/2231-5675.2022.00044 · Cited by 1
Triazine Dendrimers: Biomedical Application
Mehra, N. K., Jain, K., & Jain, N. K. (2016) · Taylor & Francis eBooks · doi:10.1081/e-ebpp-120049279 · Cited by 1
Turner, K. B. (2011) · UKnowledge (University of Kentucky)
Wagner, N. J., Quatrano, L. A., & Nicholson, C. E. (2006) · Technology and Health Care · doi:10.3233/thc-2006-14106
ENGINEERING PROTEINS WITH UNIQUE CHARACTERISTICS FOR DIAGNOSTICS AND BIOSENSORS
Joel, S. (2011) · UKnowledge (University of Kentucky)
Christopher, C., Heath, D., & Connolly, P. (2011) · InTech eBooks · doi:10.5772/19340
Layer-by-Layer Technology and Its Implications in the Field of Glucose Nanobiosensors
Sasi, S. P. (2014) · Advances in chemical and materials engineering book series · doi:10.4018/978-1-4666-6363-3.ch019
Chapter 3 Non-invasive analytics for point-of-care testing of glucose
Vashist, S. K., & Luong, J. H. T. (2016) · CRC Press eBooks · doi:10.1201/9781315366746-4
Fluorescence-Enhanced Mid-Infrared Photothermal MicroscopyPreprint
Zhang, Y., Zong, H., Zong, C., Tan, Y., Zhang, M., Zhan, Y., & Cheng, J. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2104.02825
Graphdiyne‐Based Materials in Sensors and Separation Applications
Guo, Y., Pan, C., & Zhu, Y. (2021) · doi:10.1002/9783527828470.ch9
McNichols, R. J. (2014) · CRC Press eBooks · doi:10.1201/b17289-4
FRET-Based Nanosensors for Intracellular Glucose Monitoring
Veetil, J. V., Jin, S., & Ye, K. (2010) · CRC Press eBooks · doi:10.1201/b10450-6
A Fractal Analysis of Binding and Dissociation of Glucose to Different Biosensor Surfaces
Sadana, A., & Sadana, N. (2015) · Elsevier eBooks · doi:10.1016/b978-0-444-53794-2.00007-0
Sadana, A., & Sadana, N. (2015) · Elsevier eBooks · doi:10.1016/b978-0-444-53794-2.00006-9
Charneca, A., Karmali, A., & Vieira, M. P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.06.037
Bhatt, N., & Mehata, M. S. (2026) · Materials Science and Engineering B · doi:10.1016/j.mseb.2026.119196
Graphene-based liquid-gated transistors for biosensing
Hugo, A. (2020) · theses.fr (ABES) · doi:10.70675/8e2266a7z34f0z4621z8133zaf62812bfe75
Palekar, S. D., Kalambe, J. P., & Patil, G. C. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.128832
Protein engineering for biosensor development
Miklos, A. E. (2008)
Metadata
- Authors
- Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S.
- Affiliations
- University of Kentucky (US)
- Corresponding author
- Daunert, Sylvia
- Venue
- Journal of Fluorescence
- Published
- 2004-09
- Volume
- 14
- Issue
- 5
- Pages
- 535-547
- ISSN
- 1053-0509 (ISSN-L)
- 1573-4994
- OpenAlex
- W2042531272
- Cited by
- 154
- References
- 49
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2022: 3 · 2021: 7 · 2020: 8 · 2019: 6 · 2018: 9 · 2017: 4 · 2016: 8 · 2015: 10 · 2014: 8 · 2013: 8 · 2012: 14
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Fluorescence (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- glucose sensor, fluorescent biosensor, in vivo glucose monitoring, glucose recognition, glucose receptor
- MeSH terms
- Geobacillus stearothermophilus, Boronic Acids, Fluorescent Dyes, Fluorometry, Glucokinase, Glucose, Glucose Oxidase, Humans, Monitoring, Physiologic, Monosaccharide Transport Proteins, Mutation, Protein Conformation, Biosensing Techniques, Molecular Structure, Fluorescence Resonance Energy Transfer, Lectins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review