The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Abstract
The importance of glucose monitoring for in vivo as well as for ex vivo applications has driven a vast number of scientific groups to pursue the development of an advanced glucose sensor. Such a sensor must be robust, versatile, and capable of the long-term, accurate and reproducible detection of glucose levels in various testing media. Among the different configurations and signal transduction mechanisms used, fluorescence-based glucose sensors constitute a growing class of glucose sensors represented by an increasing number of significant contributions to the field over the last few years. This manuscript reviews the progress in the development of fluorescence based glucose sensors resulting from the advances in the design of new receptor systems for glucose recognition and the utilization of new fluorescence transduction schemes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Photobleaching of the fluorophore and scattering in tissue are significant drawbacks.19,35–36”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [35]
In the citing paper
“While optical detection provides sensitive detection without damaging the host, skin pigmentation and epidermal thickness can negatively impact the analytical response among hosts.35–36”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [35]
Citations
Cites
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12 · Cited by 765
James, T. D., Sandanayake, K. R. A. S., Iguchi, R., & Shinkai, S. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00140a013 · Cited by 486
Yoon, J., & Czarnik, A. W. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00040a067 · Cited by 476
Plant lectins: Occurrence, biochemistry, functions and applications
Rüdiger, H. E. F., & Gabius, H. (2001) · Glycoconjugate Journal · doi:10.1023/a:1020687518999 · Cited by 460
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 369
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 354
Imaging of the Dynamics of Glucose Uptake in the Cytosol of COS-7 Cells by Fluorescent Nanosensors
Fehr, M., Lalonde, S., Lager, I., Wolff, M. W., & Frommer, W. B. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m301333200 · Cited by 302
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Eggert, H., Frederiksen, J., Morin, C., & Norrild, J. C. (1999) · The Journal of Organic Chemistry · doi:10.1021/jo9819279 · Cited by 260
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
A Fluorescence Affinity Hollow Fiber Sensor for Continuous Transdermal Glucose Monitoring
Ballerstädt, R., & Schultz, J. S. (2000) · Analytical Chemistry · doi:10.1021/ac000215r · Cited by 192
Glucose Sensor for Low-Cost Lifetime-Based Sensing Using a Genetically Engineered Protein
Tolosa, L. M., Gryczynski, I., Randers‐Eichhorn, L., Dattelbaum, J. D., Castellano, F. N., Rao, G., & Lakowicz, J. R. (1999) · Analytical Biochemistry · doi:10.1006/abio.1998.2974 · Cited by 188
Marvin, J. S., & Hellinga, H. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972993f · Cited by 179
A glucose-selective fluorescence sensor based on boronicacid-diol recognition
Karnati, V. V. R., Gao, X., Gao, S., Yang, W., Ni, W., Sankar, S. S., & Wang, B. (2002) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/s0960-894x(02)00767-9 · Cited by 150
Fluorescent nano-PEBBLE sensors designed for intracellular glucose imaging
Xu, H., Aylott, J. W., & Kopelman, R. (2002) · The Analyst · doi:10.1039/b202782h · Cited by 143
Monoboronic Acid Sensor That Displays Anomalous Fluorescence Sensitivity to Glucose
Cao, H., Diaz, D. I., DiCésare, N., Lakowicz, J. R., & Heagy, M. D. (2002) · Organic Letters · doi:10.1021/ol025723x · Cited by 140
Wolfbeis, O. S., Oehme, I., Papkovskaya, N., & Klimant, I. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00073-1 · Cited by 140
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Journal of Fluorescence · doi:10.1023/a:1026103804104 · Cited by 120
A General Semisynthetic Method for Fluorescent Saccharide-Biosensors Based on a Lectin
Hamachi, I., Nagase, T., & Shinkai, S. (2000) · Journal of the American Chemical Society · doi:10.1021/ja002044d · Cited by 107
Ye, K., & Schultz, J. S. (2003) · Analytical Chemistry · doi:10.1021/ac034022q · Cited by 107
Optical assay for glucose based on the luminescnence decay time of the long wavelength dye Cy5™
Tolosa, L. M., Malak, H. M., Raob, G., & Lakowicz, J. R. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00275-x · Cited by 96
A Modular Fluorescence Intramolecular Energy Transfer Saccharide Sensor
Arimori, S., Bell, M. L., Oh, C. S., & James, T. D. (2002) · Organic Letters · doi:10.1021/ol026802b · Cited by 94
Lifetime-Based Sensing of Glucose Using Energy Transfer with a Long Lifetime Donor
Tolosa, L. M., Szmacinski, H., Rao, G., & Lakowicz, J. R. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2180 · Cited by 93
Ballerstädt, R., & Schultz, J. S. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00042-1 · Cited by 89
Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
Heinemann, L., & Schmelzeisen‐Redeker, G. (1998) · Diabetologia · doi:10.1007/s001250050998 · Cited by 86
Salins, L. L. E., Miller, R. W., Ensor, M., & Daunert, S. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5131 · Cited by 86
Self-citationModular fluorescence sensors for saccharides
Arimori, S., Bell, M. L., Oh, C. S., Frimat, K. A., & James, T. D. (2002) · Journal of the Chemical Society Perkin Transactions 1 · doi:10.1039/b108998f · Cited by 82
Evaluation of Two Synthetic Glucose Probes for Fluorescence-Lifetime-Based Sensing
DiCésare, N., & Lakowicz, J. R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5170 · Cited by 81
D’Auria, S., Heřman, P., Rossi, M., & Lakowicz, J. R. (1999) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1999.1330 · Cited by 77
Fast Thermal Breaking and Formation of a B–N Bond in 2‐(Aminomethyl)benzeneboronates1)
Burgemeister, T., Grobe-Einsler, R., Grotstollen, R., Mannschreck, A., & Wulff, G. (1981) · Chemische Berichte · doi:10.1002/cber.19811141021 · Cited by 76
Monosaccharide Detection with 4,7-Phenanthrolinium Salts: Charge-Induced Fluorescence Sensing
Suri, J. T., Cordes, D. B., Cappuccio, F. E., Wessling, R. A., & Singaram, B. (2003) · Langmuir · doi:10.1021/la034270h · Cited by 73
Determination of Glucose in Blood Based on the Intrinsic Fluorescence of Glucose Oxidase
Sierra, J. F., Galbán, J., & Castillo, J. R. (1997) · Analytical Chemistry · doi:10.1021/ac9611327 · Cited by 63
An optical biosensor using a fluorescent, swelling sensing element
McCurley, M. F. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)90015-9 · Cited by 47
D’Auria, S., DiCésare, N., Staiano, M., Gryczynski, Z. K., Rossi, M., & Lakowicz, J. R. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5544 · Cited by 47
Østergaard, J., Schou, C., Larsen, C., & Heegaard, N. H. H. (2002) · Analytical Chemistry · doi:10.1021/ac0261146 · Cited by 43
A time-resolved near-infrared fluorescence assay for glucose: opportunities for trans-dermal sensing
Rolinski, O. J., Birch, D. J. S., McCartney, L. J., & Pickup, J. C. (2000) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/s1011-1344(99)00148-7 · Cited by 39
Tuning saccharide selectivity in modular fluorescent sensors
Arimori, S., Consiglio, G. A., Phillips, M. D., & James, T. D. (2003) · Tetrahedron Letters · doi:10.1016/s0040-4039(03)00942-0 · Cited by 34
Fluorometric sensors based on chemically modified enzymes Glucose determination in drinks
Sanz, V. (2003) · Talanta · doi:10.1016/s0039-9140(03)00075-4 · Cited by 33
Rational Design of a Calcium Sensing System Based on Induced Conformational Changes of Calmodulin
Schauer-Vukašinović, V., Cullen, L., & Daunert, S. (1997) · Journal of the American Chemical Society · doi:10.1021/ja972139o · Cited by 32
Self-citationResponsive drug delivery systems.
Deo, S. K., Moschou, E. A., Peteu, S. F., Bachas, L. G., & Daunert, S. (2003) · PubMed · Cited by 31
Self-citationImplantable glucose sensors: Present status and future developments
Kerner, W. (2001) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-2001-18593 · Cited by 30
D’Auria, S., Alfieri, F., Staiano, M., Pelella, F., Rossi, M., Scirè, A., Tanfani, F., Bertoli, E., Grycznyski, Z., & Lakowicz, J. R. (2004) · Biotechnology Progress · doi:10.1021/bp0341848 · Cited by 26
Eggert, H., Frederiksen, J., Morin, C., & Norrild, J. C. (1999) · ChemInform · doi:10.1002/chin.199937179 · Cited by 25
Sensing metabolites using donor–acceptor nanodistributions in fluorescence resonance energy transfer
Rolinski, O. J., Birch, D. J. S., McCartney, L. J., & Pickup, J. C. (2001) · Applied Physics Letters · doi:10.1063/1.1367308 · Cited by 16
Electrochemical biosensors for food analysis and the food industry
Palleschi, G., & Cubadda, R. (2001) · Italian Journal of Food Science · Cited by 10
Wenner, B. R., Douglass, P. M., Shrestha, S., Sharma, B. V., Lai, S., Madou, M. J., & Daunert, S. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.426736 · Cited by 6
Self-citationOptical sensing systems based on biomolecular recognition of recombinant proteins
Salins, L. L. E., Schauer-Vukašinović, V., & Daunert, S. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.308378 · Cited by 5
Self-citationBurgemeister, T., Grobe-Einsler, R., Grotstollen, R., Mannschreck, A., & Wulff, G. (1982) · ChemInform · doi:10.1002/chin.198201233 · Cited by 3
Research works printed but not linked: 1
- H. M. Heise (2000). In R. A. Meyers (Ed.), Encyclopedia of Analytical Chemistry: Instrumentation and Applications, Wiley, Chichester, U. K. Vol. I, 56–83.
Cited by
Sorted by citations
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 536
Boronic acid building blocks: tools for self assembly
Nishiyabu, R., Kubo, Y., James, T. D., & Fossey, J. (2010) · Chemical Communications · doi:10.1039/c0cc02921a · Cited by 506
Optical methods for sensing glucose
Steiner, M., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 498
Boronic acid building blocks: tools for sensing and separation
Nishiyabu, R., Kubo, Y., James, T. D., & Fossey, J. (2010) · Chemical Communications · doi:10.1039/c0cc02920c · Cited by 414
Metadata
- Authors
- Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S.
- Affiliations
- University of Kentucky (US)
- Corresponding author
- Daunert, Sylvia
- Venue
- Journal of Fluorescence
- Published
- 2004-09
- Volume
- 14
- Issue
- 5
- Pages
- 535-547
- ISSN
- 1053-0509 (ISSN-L)
- 1573-4994
- OpenAlex
- W2042531272
- Cited by
- 154
- References
- 49
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2022: 3 · 2021: 7 · 2020: 8 · 2019: 6 · 2018: 9 · 2017: 4 · 2016: 8 · 2015: 10 · 2014: 8 · 2013: 8 · 2012: 14
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Fluorescence (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- glucose sensor, fluorescent biosensor, in vivo glucose monitoring, glucose recognition, glucose receptor
- MeSH terms
- Geobacillus stearothermophilus, Boronic Acids, Fluorescent Dyes, Fluorometry, Glucokinase, Glucose, Glucose Oxidase, Humans, Monitoring, Physiologic, Monosaccharide Transport Proteins, Mutation, Protein Conformation, Biosensing Techniques, Molecular Structure, Fluorescence Resonance Energy Transfer, Lectins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review