The influence of abutment surface roughness on plaque accumulation and peri‐implant mucositis
The DOI matches its Crossref record.
Abstract
Bacterial adhesion to intra‐oral, hard surfaces is firmly influenced by the surface roughness of these structures. Previous studies showed a remarkable higher subgingival bacterial load on rough surfaces when compared to smooth sites. More recently, the additional effect of a further smoothening of intra‐oral hard surfaces on clinical and microbiological parameters was examined in a short‐term experiment. The results indicated that a reduction in surface roughness below Ra=0.2 μm, the so‐called “threshold Ra”, had no further effect on the quantitative/qualitative microbiological adhesion or colonisation, neither supra‐ nor subgingivally. This study aims to examine the long‐term effects of smoothening immoral hard transgingival surfaces. In 6 patients expecting an overdenture in the lower jaw, supported by endosseus titanium implants, 2 different abutments (transmucosal part of the implant): a standard machined titanium (Ra=0.2 μm) and one highly polished and made of a ceramic material (Ra=0.06 μm) were randomly installed. After 3 months of intra‐oral exposure, supra‐ and subgingival plaque samples from both abutments were compared with each other by means of differential phase‐contrast microscopy (DPCM). Clinical periodontal parameters (probing depth, gingival recession, bleeding upon probing and Periotest‐value) were recorded around each abutment. After 12 months. the supra‐ and subgingival samples were additionally cultured in aerobic, CO,‐enriched and anaerobic conditions. The same clinical parameters as at the 3‐month interval were recorded after 12 months. At 3 months, spirochetes and motile organisms were only detected subgingivally around the titanium abutments. After 12 months, however, both abutment‐types harboured equal proportions of spirochetes and motile organisms, both supra‐ and sub‐gingivally. The microbial culturing (month 12) failed to detect large interabutment differences. The differences in number of colony forming units (aerobic and anaerobic) were within one division of a logarithmic scale. The aerobic culture data showed a higher proportion of Gram‐negative organisms in the subgingival flora of the rougher abutments. From the group of potentially “pathogenic” bacteria, only Prevotellu inter‐media and Fusobacterium nucleatum were detected after anaerobic culturing and again the inter‐abutment differences were negligible. Clinically, the smoothest abutment showed a slightly higher increase in probing depth between months 3 and 12, and more bleeding on probing. The present results confirm the findings of our previous short‐term study, indicating that a further reduction of the surface roughness, below a certain “threshold Ra”(0.2 μm), has no major impact on the supra‐ and subgingival microbial composition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
Self-citationEffect of material characteristics and/or surface topography on biofilm development
Teughels, W., Van Assche, N., Sliepen, I., & Quirynen, M. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01353.x · Cited by 1,358
Self-citationZheng, S., Bawazir, M., Dhall, A., Kim, H.-E., He, L., Heo, J., & Hwang, G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.643722 · Cited by 872
Infectious risks for oral implants: a review of the literature
Quirynen, M., De Soete, M., & Van Steenberghe, D. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130101.x · Cited by 665
Self-citationBacterial Adhesion on Commercially Pure Titanium and Zirconium Oxide Disks: An In Vivo Human Study
Scarano, A., Piattelli, M., Caputi, S., Favero, G. A., & Piattelli, A. (2004) · Journal of Periodontology · doi:10.1902/jop.2004.75.2.292 · Cited by 622
Cobb, C. M. (2002) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.29.s2.4.x · Cited by 566
Heitz‐Mayfield, L. J. A., & Salvi, G. E. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12953 · Cited by 383
A role for surface topography in creating and maintaining bone at titanium endosseous implants
Cooper, L. F. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.111966 · Cited by 336
Heitz‐Mayfield, L. J. A., & Salvi, G. E. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0488 · Cited by 307
Degidi, M., Artese, L., Scarano, A., Perrotti, V., Gehrke, P., & Piattelli, A. (2006) · Journal of Periodontology · doi:10.1902/jop.2006.77.1.73 · Cited by 298
Wassmann, T., Kreis, S., Behr, M., & Buergers, R. (2017) · International Journal of Implant Dentistry · doi:10.1186/s40729-017-0093-3 · Cited by 252
“2 μm; below this threshold, a change in roughness did not significantly affect the quantity of plaque accumulation [27, 37].”
BackgroundDifferential response of Staphylococci and osteoblasts to varying titanium surface roughness
Wu, Y., Zitelli, J. P., TenHuisen, K. S., Yu, X., & Libera, M. R. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.001 · Cited by 248
Multifunctional Coatings and Nanotopographies: Toward Cell Instructive and Antibacterial Implants
Mas‐Moruno, C., Su, B., & Dalby, M. J. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801103 · Cited by 242
The Peri‐Implantitis: Implant Surfaces, Microstructure, and Physicochemical Aspects
Mouhyi, J., Dohan Ehrenfest, D. M., & Albrektsson, T. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2009.00244.x · Cited by 237
“However, there exists no correlation between these implant surfaces and the selection of aggressive bacterial strains.(27,28) Excessive biomechanical stress may trigger periimplantitis through a promotion of the initial rupture of osseointegration.”
BackgroundIn vivo and in vitro biofilm formation on two different titanium implant surfaces
Bürgers, R., Gerlach, T., Hahnel, S., Schwarz, F., Handel, G., & Gosau, M. (2010) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01815.x · Cited by 236
Plaque formation on surface modified dental implants: An in vitro study
Größner‐Schreiber, B., Griepentrog, M., Haustein, I., Müller, W., Briedigkeit, H., Göbel, U. B., & Lange, K. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120601.x · Cited by 213
Morgan, T. D., & Wilson, M. (2001) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2001.01338.x · Cited by 210
“Surface roughness in¯uences the adhesion of microorganisms to catheters (Tebbs et al. 1994), enamel surfaces (GuÈrgan et al. 1997) and tooth surfaces (Bollen et al. 1996), probably because of the greater surface area provided and the provision of protected sites for colonization.”
BackgroundInfluence of surface roughness on streptococcal adhesion forces to composite resins
Mei, L., Busscher, H. J., van der Mei, H. C., & Ren, Y. (2011) · Dental Materials · doi:10.1016/j.dental.2011.03.017 · Cited by 198
“studies report that, when the surface roughness is lower than 200 nm, surface roughness has no significant effect on plaque accumulation and microbial composition on titanium abutments in vivo [23,24] nor on adhesion and colonization by S.”
BackgroundGlauser, R., Schüpbach, P., Gottlow, J., & Hämmerle, C. H. F. (2005) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2005.tb00074.x · Cited by 192
S upragingival C alculus: F ormation and C ontrol
Jin, Y., & Yip, H.-K. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300506 · Cited by 181
Bactericidal Effect of the Er:YAG Laser on Dental Implant Surfaces: An In Vitro Study
Kreisler, M., Kohnen, W., Marinello, C., Götz, H., Duschner, H., Jansen, B., & D'Hoedt, B. (2002) · Journal of Periodontology · doi:10.1902/jop.2002.73.11.1292 · Cited by 178
Abuzar, M. A., Bellur, S., Duong, N., Kim, B. B., Lu, P., Palfreyman, N., Surendran, D., & Tran, V. T. (2010) · Journal of Oral Science · doi:10.2334/josnusd.52.577 · Cited by 174
“2 μm where no further reduction in plaque accumulation is expected under that level (21,23,27).”
BackgroundHealth, Maintenance, and Recovery of Soft Tissues around Implants
Wang, Y., Zhang, Y., & Miron, R. J. (2016) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12343 · Cited by 161
Barão, V. A. R., Mathew, M. T., Assunção, W. G., Yuan, J. C., Wimmer, M. A., & Sukotjo, C. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02265.x · Cited by 161
“In dentistry, roughness is an important property of adhesion and colonization of bacteria (Morgan & Wilson 2001); therefore, a greater biofilm accumulation may be expected on the Ti surface after corrosion mainly at pH 3, which may lead to peri-implantitis (Bollen et al. 1996).”
BackgroundEffects of polishing techniques on the surface roughness of acrylic denture base resins
Kuhar, M., & Funduk, N. (2005) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2004.10.002 · Cited by 160
Biofilm and dental implant: The microbial link
Dhir, S. (2013) · Journal of Indian Society of Periodontology · doi:10.4103/0972-124x.107466 · Cited by 129
“Table 3: Effect of Ra of implant and the biofilm formed [23,24,36] Ra Effect on biofilm No qualitative/quantitative change in biofilm Ra – Surface roughness cornerstone of successful implantology.”
Influential
Metadata
- Authors
- Bollen, C. M. L., Papaioanno, W., Van Eldere, J., Schepers, E., Quirynen, M., & Van Steenberghe, D.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 7
- Issue
- 3
- Pages
- 201-211
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2131933574
- Cited by
- 661
- References
- 0
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.