Risk of indoor airborne infection transmission estimated from carbon dioxide concentration: Indoor airborne transmission of infectious diseases
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The Wells-Riley equation, which is used to model the risk of indoor airborne transmission of infectious diseases such as tuberculosis, is sometimes problematic because it assumes steady-state conditions and requires measurement of outdoor air supply rates, which are frequently difficult to measure and often vary with time. We derive an alternative equation that avoids these problems by determining the fraction of inhaled air that has been exhaled previously by someone in the building (rebreathed fraction) using CO2 concentration as a marker for exhaled-breath exposure. We also derive a non-steady-state version of the Wells-Riley equation which is especially useful in poorly ventilated environments when outdoor air supply rates can be assumed constant. Finally, we derive the relationship between the average number of secondary cases infected by each primary case in a building and exposure to exhaled breath and demonstrate that there is likely to be an achievable critical rebreathed fraction of indoor air below which airborne propagation of common respiratory infections and influenza will not occur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infectious Diseases of Humans: Dynamics and Control
Anderson, R. M., & May, R. M. (1991) · doi:10.1093/oso/9780198545996.001.0001 · Cited by 6,179
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932
AN OUTBREAK OF INFLUENZA ABOARD A COMMERCIAL AIRLINER
MOSER, M. R., BENDER, T. R., MARGOLIS, H. S., NOBLE, G. R., KENDAL, A. P., & RITTER, D. G. (1979) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112781 · Cited by 605
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Self-citationAerosol transmission of rhinovirus colds
Dick, E. C., Jennings, L. C., Mink, K. A., Wartgow, C. D., & Inborn, S. L. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.3.442 · Cited by 280 · cited 1×
“To demonstrate the utility of Equation 8, the carbon dioxide-based risk equation, and to generate parameters for describing the relationship of building environment to RA0 we estimate the quantum generation rate of rhinovirus 16 based on experimental data published by Dick et al. (1987).”
MethodAirborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.302 · Cited by 261
Survival Characteristics of Airborne Human Coronavirus 229E
Ijaz, M. K., Brunner, A. H., Sattar, S. A., Nair, R. C., & Johnson-Lussenburg, C. M. (1985) · Journal of General Virology · doi:10.1099/0022-1317-66-12-2743 · Cited by 254
Clearing the Air: The Theory and Application of Ultraviolet Air Disinfection
Riley, R. L., & Nardell, E. A. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.5.1286 · Cited by 204
Catanzaro, A. (1982) · American Review of Respiratory Disease · doi:10.1164/arrd.1982.125.5.559 · Cited by 177
The Relative Efficacy of Respirators and Room Ventilation in Preventing Occupational Tuberculosis
Fennelly, K. P., & Nardell, E. A. (1998) · Infection Control and Hospital Epidemiology · doi:10.1086/647719 · Cited by 109
Airborne Contagion and Air Hygiene: An Ecological Study of Droplet Infection
(1957) · Tubercle · doi:10.1016/s0041-3879(57)80076-2 · Cited by 58
A Model for Obtaining Predictable Natural Transmission of Rhinoviruses in Human Volunteers
Meschievitz, C. K., Schultz, S. B., & Dick, E. C. (1984) · Journal of Infectious Diseases · doi:10.1093/infdis/150.2.195 · Cited by 56
Dick, E. C., Hossain, S. U., Mink, K. A., Meschievitz, C. K., Schultz, S. B., Raynor, W. J., & Inhorn, S. L. (1986) · Journal of Infectious Diseases · doi:10.1093/infdis/153.2.352 · Cited by 49
Barnhart, S., Sheppard, L. A., Beaudet, N., Stover, B. D., & Balmes, J. R. (1997) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-199709000-00008 · Cited by 45
Thatcher, T. L., Environmental Protection Agency (EPA), McKone, T. E., Fisk, W., Sohn, M., Delp, W., Riley, W. J., & Sextro, R. G. (2001) · doi:10.2172/820780 · Cited by 24
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Perspectives on the basic reproductive ratio
Heffernan, J. M., Smith, R. J., & Wahl, L. M. (2005) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0042 · Cited by 1,228
Buonanno, G., Stabile, L., & Morawska, L. (2020) · Environment International · doi:10.1016/j.envint.2020.105794 · Cited by 780
Miller, S. L., Nazaroff, W. W., Jimenez, J. L., Boerstra, A., Buonanno, G., Dancer, S. J., Kurnitski, J., Marr, L. C., Morawska, L., & Noakes, C. (2021) · Indoor Air · doi:10.1111/ina.12751 · Cited by 734
Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant
Li, Y., Qian, H., Hang, J., Chen, X., Cheng, P., Ling, H., Wang, S., Liang, P., Li, J., Xiao, S., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107788 · Cited by 689
Metadata
- Authors
- Rudnick, S. N., & Milton, D. K.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2003-09
- Volume
- 13
- Issue
- 3
- Pages
- 237-245
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2021019339
- Cited by
- 624
- References
- 18
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.