CoChat

Risk of indoor airborne infection transmission estimated from carbon dioxide concentration: Indoor airborne transmission of infectious diseases

Open access
Rudnick, S. N., Milton, D. K. · 2003 · Indoor Air
Cited by 624

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

The Wells-Riley equation, which is used to model the risk of indoor airborne transmission of infectious diseases such as tuberculosis, is sometimes problematic because it assumes steady-state conditions and requires measurement of outdoor air supply rates, which are frequently difficult to measure and often vary with time. We derive an alternative equation that avoids these problems by determining the fraction of inhaled air that has been exhaled previously by someone in the building (rebreathed fraction) using CO2 concentration as a marker for exhaled-breath exposure. We also derive a non-steady-state version of the Wells-Riley equation which is especially useful in poorly ventilated environments when outdoor air supply rates can be assumed constant. Finally, we derive the relationship between the average number of secondary cases infected by each primary case in a building and exposure to exhaled breath and demonstrate that there is likely to be an achievable critical rebreathed fraction of indoor air below which airborne propagation of common respiratory infections and influenza will not occur.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0668.2003.00189.x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 624

Metadata

Authors
Rudnick, S. N., & Milton, D. K.
Venue
Indoor Air
Published
2003-09
Volume
13
Issue
3
Pages
237-245
ISSN
0905-6947 (ISSN-L)
OpenAlex
W2021019339
Cited by
624
References
18
FWCI
4.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.