In vivo model of the mechanical properties of the human skin under suction
Open accessThe DOI matches its Crossref record.
Abstract
Background/aims: A new method for the in vivo characterization of the mechanical properties of skin has been developed. This comprises a suction chamber and an ultrasound device to measure both the vertical displacement of the skin's surface, and the skin's thickness. Methods: A mathematical model of the mechanical behaviour of a taught elastic membrane is used to obtain a set of parameters intrinsic to the skin, such as Young's modulus (E) and the initial stress (σ 0), which reflect the stiffness and the natural tension of the skin, respectively. We also calculated an index of non‐elasticity of the skin (unrestored energy ratio, UER), which takes into account the volume of tissue mobilized. It determines a ratio between the energy input to the skin and the energy it dissipates. These parameters were evaluated from the volar forearm of 10 normal male volunteers. Results: The results were: 129±88 kPa for E, 13.5±5 kPa for σ 0, and 0.42±0.04 for UER; with reproducibilities of 9.5%, 12.4% and 6.4%, respectively. Conclusions: This new suction device was found useful for the study of the behaviour of the skin, and the device may be used for the evaluation of certain skin diseases and their therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Substrate Modulus Directs Neural Stem Cell Behavior
Saha, K., Keung, A. J., Irwin, E. F., Li, Y., Little, L., Schaffer, D. V., & Healy, K. E. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.132217 · Cited by 1,092
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Ma, Z., Huang, Q., Xu, Q., Zhuang, Q., Zhao, X., Yang, Y., Qiu, H., Yang, Z., Wang, C., Chai, Y., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00902-3 · Cited by 772
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
“15 MPa for sucion tests [7,8].”
BackgroundSun, X., Qin, Z., Ye, L., Zhang, H., Yu, Q., Wu, X., Li, J., & Yao, F. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.122832 · Cited by 552
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
The relationship between skin function, barrier properties, and body‐dependent factors
Dąbrowska, A. K., Spano, F., Derler, S., Adlhart, C., Spencer, N. D., & Rossi, R. M. (2018) · Skin Research and Technology · doi:10.1111/srt.12424 · Cited by 496
Skin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 480
Capanema, N. S. V., Mansur, A. A. P., de Jesus, A. C., Carvalho, S. M., de Oliveira, L. C., & Mansur, H. S. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.08.124 · Cited by 456
A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347
“(8) using 100 mbar suction and an aperture size of 6 mm resulted in E = 153 kPa.”
MethodResultBioprinting: From Tissue and Organ Development to in Vitro Models
Mota, C., Camarero-Espinosa, S., Baker, M. B., Wieringa, P., & Moroni, L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00789 · Cited by 345
Age-dependent biomechanical properties of the skin
Pawlaczyk, M., Lelonkiewicz, M., & Wieczorowski, M. (2013) · Advances in Dermatology and Allergology · doi:10.5114/pdia.2013.38359 · Cited by 335
Gaspar-Pintiliescu, A., Stanciuc, A.-M., & Craciunescu, O. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.07.155 · Cited by 327
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
The Nano-Scale Mechanical Properties of the Extracellular Matrix Regulate Dermal Fibroblast Function
Achterberg, V. F., Buscemi, L., Diekmann, H., Smith-Clerc, J., Schwengler, H., Meister, J.-J., Wenck, H., Gallinat, S., & Hinz, B. (2014) · Journal of Investigative Dermatology · doi:10.1038/jid.2014.90 · Cited by 290
Epithelial mechanobiology, skin wound healing, and the stem cell niche
Evans, N. D., Oreffo, R. O. C., Healy, E., Thurner, P. J., & Man, Y. H. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.04.023 · Cited by 265
Yu, B., Kang, S.-Y., Akthakul, A., Ramadurai, N., Pilkenton, M., Patel, A., Nashat, A., Anderson, D. G., Sakamoto, F. H., Gilchrest, B. A., et al. (2016) · Nature Materials · doi:10.1038/nmat4635 · Cited by 240
Leach, J. B., Brown, X. Q., Jacot, J. G., DiMilla, P. A., & Wong, J. Y. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/003 · Cited by 211
Zahouani, H., Pailler‐Mattei, C., Sohm, B., Vargiolu, R., Cenizo, V., & Debret, R. (2009) · Skin Research and Technology · doi:10.1111/j.1600-0846.2008.00329.x · Cited by 209
“The most commonly used methods are based on the measurement of suction, which consists in applying a negative pressure to the skin (1, 2), torsion (3, 4) and traction, by applying a linear displacement in the horizontal plane of the skin (5).”
BackgroundMethodDynamic indentation on human skin in vivo: ageing effects
Boyer, G., Laquièze, L., Le Bot, A., Laquièze, S., & Zahouani, H. (2009) · Skin Research and Technology · doi:10.1111/j.1600-0846.2008.00324.x · Cited by 195
Three-dimensional printing of multilayered tissue engineering scaffolds
Bittner, S. M., Guo, J. L., Melchiorri, A., & Mikos, A. G. (2018) · Materials Today · doi:10.1016/j.mattod.2018.02.006 · Cited by 185
Engler, A. J., Rehfeldt, F., Sen, S., & Discher, D. E. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(07)83022-6 · Cited by 182
“…2004) is clearly softer than unstimulated, striated muscle (E 10– 20 kPa transverse to the muscle axis; Engler et al., 2004b), and muscle appears to be softer than the combination of epithelial cells, fibroblasts, and other cell types that make up skin (E 50 kPa; Diridollou et al., 2000).”
BackgroundSkin ageing: changes of physical properties of human skin in vivo
Diridollou, S., Vabre, V., Berson, M., Vaillant, L., Black, D., Lagarde, J. M., Grégoire, J. M., Gall, Y., & Patat, F. (2001) · International Journal of Cosmetic Science · doi:10.1046/j.0412-5463.2001.00105.x · Cited by 178
Self-citationKonstantinova, J., Jiang, A., Althoefer, K., Dasgupta, P., & Nanayakkara, T. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2325794 · Cited by 166
A nonlinear elastic behavior to identify the mechanical parameters of human skin in vivo
Delalleau, A., Josse, G., Lagarde, J. ‐., Zahouani, H., & Bergheau, J. ‐. (2008) · Skin Research and Technology · doi:10.1111/j.1600-0846.2007.00269.x · Cited by 164
“(21) have respectively found Young’s modulus about 250, 130 and 150 kPa.”
BackgroundMethodSelf-citationViscoelastic response of human skin to low magnitude physiologically relevant shear
Holt, B., Tripathi, A., & Morgan, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.008 · Cited by 161
Closed-Loop Haptic Feedback Control Using a Self-Sensing Soft Pneumatic Actuator Skin
Sonar, H. A., Gerratt, A. P., Lacour, S. P., & Paik, J. (2020) · Soft Robotics · doi:10.1089/soro.2019.0013 · Cited by 159
Chen, A. I., Balter, M. L., Chen, M. I., Gross, D., Alam, S. K., Maguire, T. J., & Yarmush, M. L. (2016) · Medical Physics · doi:10.1118/1.4951729 · Cited by 158
Skin-Friendly Electronics for Acquiring Human Physiological Signatures
Zhang, Y., & Tao, T. H. (2019) · Advanced Materials · doi:10.1002/adma.201905767 · Cited by 140
Sex‐ and site‐dependent variations in the thickness and mechanical properties of human skin in vivo
Diridollou, S., Black, D., Lagarde, J. M., Gall, Y., Berson, M., Vabre, V., Patat, F., & Vaillant, L. (2000) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2000.00037.x · Cited by 99
Self-citationMotwani, M. S., Khan, K., Pai, A., & Joshi, R. (2020) · Journal of Cosmetic Dermatology · doi:10.1111/jocd.13404 · Cited by 9
Metadata
- Authors
- Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 6
- Issue
- 4
- Pages
- 214-221
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2160911470
- Cited by
- 350
- References
- 0
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.