Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke Model

Open access
Dirnagl, Ulrich, Kaplan, Bruce, Jacewicz, Michael, Pulsinelli, William·1989·Journal of Cerebral Blood Flow & Metabolism

Abstract

Laser-Doppler flowmetry (LDF), a new method allowing instantaneous, continuous, and noninvasive measurements of microcirculatory blood flow in a small tissue sample, was evaluated for its accuracy in monitoring regional cerebral blood flow (rCBF) in the cortical microcirculation after focal cerebral ischemia. Wistar and spontaneously hypertensive rats (SHR, n = 19) were subjected to permanent occlusion of the middle cerebral and common carotid arteries. Absolute rCBF in a tissue sample of the ischemic hemisphere was measured autoradiographically with [14 C]iodoantipyrine as a tracer and compared to rCBF measured by LDF. Additionally, the percent change in rCBF between baseline and ischemic values was compared for both methods. Absolute rCBF values recorded with LDF correlated poorly ( r = 0.54) with [14 C]iodoantipyrine measurements. In contrast, LDF readings expressed as a percentage of ischemic vs. preocclusion readings (relative LDF readings) correlated very well ( r = 0.91) with the percent change in [14 C]iodoantipyrine measurements. We conclude that LDF does not provide accurate measurements of absolute rCBF values but this method allows accurate measurements of changes in rCBF due to induction of focal cerebral ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1989.84

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 475

Metadata

Authors
Dirnagl, U., Kaplan, B., Jacewicz, M., & Pulsinelli, W.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1989-10
Volume
9
Issue
5
Pages
589-596
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2048879756
Cited by
475
References
1
FWCI
10.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke Model. https://app.cochat.ai/papers/10.1038/jcbfm.1989.84
The paper
Dirnagl, U., Kaplan, B., Jacewicz, M., & Pulsinelli, W. (1989). Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke Model. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1989.84

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.