An optical lattice clock
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The precision measurement of time and frequency is a prerequisite not only for fundamental science but also for technologies that support broadband communication networks and navigation with global positioning systems (GPS). The SI second is currently realized by the microwave transition of Cs atoms with a fractional uncertainty of 10(-15) (ref. 1). Thanks to the optical frequency comb technique, which established a coherent link between optical and radio frequencies, optical clocks have attracted increasing interest as regards future atomic clocks with superior precision. To date, single trapped ions and ultracold neutral atoms in free fall have shown record high performance that is approaching that of the best Cs fountain clocks. Here we report a different approach, in which atoms trapped in an optical lattice serve as quantum references. The 'optical lattice clock' demonstrates a linewidth one order of magnitude narrower than that observed for neutral-atom optical clocks, and its stability is better than that of single-ion clocks. The transition frequency for the Sr lattice clock is 429,228,004,229,952(15) Hz, as determined by an optical frequency comb referenced to the SI second.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Knight, J. C. (2003) · Nature · doi:10.1038/nature01940 · Cited by 1,500
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Absolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Visible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301
Radio-Frequency Spectroscopy of Ultracold Fermions
Gupta, S., Hadzibabic, Z., Zwierlein, M. W., Stan, C. A., Dieckmann, K., Schunck, C. H., van Kempen, E. G. M., Verhaar, B. J., & Ketterle, W. (2003) · Science · doi:10.1126/science.1085335 · Cited by 293
Limit on the Present Temporal Variation of the Fine Structure Constant
Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.170801 · Cited by 282
Recoil-Free Spectroscopy of Neutral Sr Atoms in the Lamb-Dicke Regime
Ido, T., & Katori, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.053001 · Cited by 172
Self-citationSpectroscopy of theS01−P03Clock Transition ofSr87in an Optical Lattice
Takamoto, M., & Katori, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.223001 · Cited by 161
Self-citationOptimal Design of Dipole Potentials for Efficient Loading of Sr Atoms
Katori, H., Ido, T., & Kuwata-Gonokami, M. (1999) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.68.2479 · Cited by 157
Self-citationAdvances in Atomic, Molecular, and Optical Physics
(2013) · Advances in atomic, molecular, and optical physics · doi:10.1016/c2012-0-03245-0 · Cited by 147
Optical Clock with Ultracold Neutral Atoms
Wilpers, G., Binnewies, T., Degenhardt, C., Sterr, U., Helmcke, J., & Riehle, F. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.230801 · Cited by 146
Porsev, S. G., Derevianko, A., & Fortson, E. N. (2004) · Physical Review A · doi:10.1103/physreva.69.021403 · Cited by 136
SPECTROSCOPY OF STRONTIUM ATOMS IN THE LAMB-DICKE CONFINEMENT
Katori, H. (2002) · Symposium on Frequency Standards and Metrology · doi:10.1142/9789812777713_0036 · Cited by 121
Self-citationControlling the Cold Collision Shift in High Precision Atomic Interferometry
Pereira Dos Santos, F., Marion, H., Bize, S., Sortais, Y., Clairon, A., & Salomon, C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.233004 · Cited by 110
Angstmann, E. J., Dzuba, V. A., & Flambaum, V. V. (2004) · Physical Review A · doi:10.1103/physreva.70.014102 · Cited by 109
Oates, C. W., Curtis, E. A., & Hollberg, L. (2000) · Optics Letters · doi:10.1364/ol.25.001603 · Cited by 89
Clock transition for a future optical frequency standard with trapped atoms
Courtillot, I., Quessada, A., Kovacich, R. P., Brusch, A., Kolker, D., Zondy, J.-J., Rovera, G. D., & Lemonde, P. (2003) · Physical Review A · doi:10.1103/physreva.68.030501 · Cited by 77
Sub-Kilohertz Optical Spectroscopy with a Time Domain Atom Interferometer
Ruschewitz, F., Peng, J.-L., Hinderthür, H., Schaffrath, N., Sengstock, K., & Ertmer, W. A. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3173 · Cited by 77
Wavelength-dependent ac Stark shift of theS01‐P13transition at657nmin Ca
Degenhardt, C., Stoehr, H., Sterr, U., Riehle, F., & Lisdat, C. (2004) · Physical Review A · doi:10.1103/physreva.70.023414 · Cited by 46
Sub-kilohertz optical spectroscopy with a time domain atom interferometer
Ruschewitz, F., Peng, J.-L., Hinderthür, H., et al. (1998) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/3285 · Cited by 43
Frequency comparison of /sup 127/I/sub 2/-stabilized Nd:YAG lasers
Hong, F.-L., Ishikawa, J., Yoda, J., Ye, J., Ma, L.-S., & Hall, J. L. (1999) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.769651 · Cited by 37
Self-citationStanding light fields for cold atoms with intrinsically stable and variable time phases
Rauschenbeutel, A., Schadwinkel, H., Gomer, V., & Meschede, D. (1998) · Optics Communications · doi:10.1016/s0030-4018(97)00669-x · Cited by 28
Frequency comparison of (127)I2-stabilized Nd:YAG lasers
Hong, F.-L., Ishikawa, J., Yoda, J., Ye, J., Ma, L.-S., & Hall, J. L. (1999) · IEEE Transactions on Instrumentation and Measurement · Cited by 13
Self-citation
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Theory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 489
Metadata
- Authors
- Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H.
- Affiliations
- The University of Tokyo (JP)
- National Metrology Institute of Japan (JP)
- Japan Science and Technology Agency (JP)
- Corresponding author
- Katori, Hidetoshi
- Venue
- Nature
- Published
- 2005-05
- Volume
- 435
- Issue
- 7040
- Pages
- 321-324
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2008960355
- Cited by
- 853
- References
- 30
- Citations by year
- 2026: 28 · 2025: 48 · 2024: 31 · 2023: 43 · 2022: 33 · 2021: 25 · 2020: 42 · 2019: 32 · 2018: 26 · 2017: 28 · 2016: 23 · 2015: 43 · 2014: 34 · 2013: 56 · 2012: 43
- FWCI
- 36.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, strontium atoms, optical frequency combs, cesium atomic clock, optical frequency measurement, ultracold atoms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.