Label-free immunodetection with CMOS-compatible semiconducting nanowires
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Semiconducting nanowires have the potential to function as highly sensitive and selective sensors for the label-free detection of low concentrations of pathogenic microorganisms. Successful solution-phase nanowire sensing has been demonstrated for ions, small molecules, proteins, DNA and viruses; however, 'bottom-up' nanowires (or similarly configured carbon nanotubes) used for these demonstrations require hybrid fabrication schemes, which result in severe integration issues that have hindered widespread application. Alternative 'top-down' fabrication methods of nanowire-like devices produce disappointing performance because of process-induced material and device degradation. Here we report an approach that uses complementary metal oxide semiconductor (CMOS) field effect transistor compatible technology and hence demonstrate the specific label-free detection of below 100 femtomolar concentrations of antibodies as well as real-time monitoring of the cellular immune response. This approach eliminates the need for hybrid methods and enables system-scale integration of these sensors with signal processing and information systems. Additionally, the ability to monitor antibody binding and sense the cellular immune response in real time with readily available technology should facilitate widespread diagnostic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Directed Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
Physics of semiconductor devices /2nd edition/
Sze, S. M. (1981) · New York eBooks · Cited by 1,599
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
The Physics of Semi-Conductor Devices: D. A.Fraser Clarendon Press, Oxford, 1977; p. IX–148
Quaranta, A. A. (1979) · Il Nuovo Cimento B Series 11 · doi:10.1007/bf02743444 · Cited by 1,170
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Sequence-Specific Label-Free DNA Sensors Based on Silicon Nanowires
Li, Z., Chen, Y., Li, X., Kamins, T. I., Nauka, K., & Williams, R. S. (2004) · Nano Letters · doi:10.1021/nl034958e · Cited by 706
Detection Limits for Nanoscale Biosensors
Sheehan, P. E., & Whitman, L. J. (2005) · Nano Letters · doi:10.1021/nl050298x · Cited by 615
Label-free detection of small-molecule–protein interactions by using nanowire nanosensors
Wang, W. U., Chen, C., Lin, K.-H., Fang, Y., & Lieber, C. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406368102 · Cited by 534
Chen, R. J., Choi, H. C., Bangsaruntip, S., Yenilmez, E., Tang, X., Wang, Q., Chang, Y.-L., & Dai, H. (2004) · Journal of the American Chemical Society · doi:10.1021/ja038702m · Cited by 516
Nanotechnologies for biomolecular detection and medical diagnostics
Cheng, M. M.-C., Cuda, G., Bunimovich, Y. L., Gaspari, M., Heath, J. R., Hill, H. D., Mirkin, C. A., Nijdam, A. J., Terracciano, R., Thundat, T., et al. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.01.006 · Cited by 474
Anisotropic etching of silicon in TMAH solutions
Tabata, O., Asahi, R., Funabashi, H., Shimaoka, K., & Sugiyama, S. (1992) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(92)80139-t · Cited by 466
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Covalent attachment of oligodeoxyribonucleotides to amine-modified Si (001) surfaces
Strother, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.18.3535 · Cited by 280
Electron Mobility in Inversion and Accumulation Layers on Thermally Oxidized Silicon Surfaces
Sun, S. C., & Plummer, J. D. (1980) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1980.1051439 · Cited by 163
Integrated nanoscale silicon sensors using top-down fabrication
Elibol, O. H., Morisette, D. T., Akin, D., Denton, J. P., & Bashir, R. (2003) · Applied Physics Letters · doi:10.1063/1.1630853 · Cited by 126
Electrochemically Programmed, Spatially Selective Biofunctionalization of Silicon Wires
Bunimovich, Y. L., Ge, G., Beverly, K. C., Ries, R. S., Hood, L., & Heath, J. R. (2004) · Langmuir · doi:10.1021/la047913h · Cited by 118
Electric-Field Assisted Growth and Self-Assembly of Intrinsic Silicon Nanowires
Englander, O., Christensen, D., Kim, J., Lin, L., & Morris, S. J. (2005) · Nano Letters · doi:10.1021/nl050109a · Cited by 113
Evoy, S., DiLello, N., Deshpande, V. V., Narayanan, A., Liu, H., Riegelman, M., Martin, B. R., Hailer, B., Bradley, J., Weiss, W., et al. (2004) · Microelectronic Engineering · doi:10.1016/j.mee.2003.09.010 · Cited by 112
Silicon p-FETs from Ultrahigh Density Nanowire Arrays
Wang, D., Sheriff, B. A., & Heath, J. R. (2006) · Nano Letters · doi:10.1021/nl052558g · Cited by 105
Liu, Y., ISHII, K., Tsutsumi, T., Masahara, M., & Suzuki, E. (2003) · IEEE Electron Device Letters · doi:10.1109/led.2003.815004 · Cited by 98
Scaling issues in chemical and biological sensors
Madou, M. J., & Cubicciotti, R. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813577 · Cited by 82
Early biochemical signals arise from low affinity TCR-ligand reactions at the cell-cell interface.
Beeson, C., Rabinowitz, J. D., Tate, K. M., Gütgemann, I., Chien, Y., Jones, P. P., Davis, M. M., & McConnell, H. M. (1996) · The Journal of Experimental Medicine · doi:10.1084/jem.184.2.777 · Cited by 53
Clément, N., Tonneau, D., Dallaporta, H., Bouchiat, V., Fraboulet, D., Mariolle, D., Gautier, J., & Safarov, V. I. (2002) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/s1386-9477(02)00288-6 · Cited by 42
Tang, T., Liu, X., Li, C., Lei, B., Zhang, D., Rouhanizadeh, M., Hsiai, T. K., & Zhou, C. (2005) · Applied Physics Letters · doi:10.1063/1.1881783 · Cited by 41
Saitoh, M., Murakami, T., & Hiramoto, T. (2003) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2003.820796 · Cited by 30
Microclusters initiate and sustain T cell signaling
Trautmann, A. (2005) · Nature Immunology · doi:10.1038/ni1205-1213 · Cited by 10
The Role of Quantization Effects on the Operation of 50 nm MOSFET and 250 nm FIBMOS Devices
Vasileska, D. (2002) · physica status solidi (b) · doi:10.1002/1521-3951(200209)233:1<83::aid-pssb83>3.0.co;2-#
Cited by
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Recent development in 2D materials beyond graphene
Gupta, A., Sakthivel, T., & Seal, S. (2015) · Progress in Materials Science · doi:10.1016/j.pmatsci.2015.02.002 · Cited by 1,558
Nanotechnology‐Enabled Energy Harvesting for Self‐Powered Micro‐/Nanosystems
Wang, Z. L., & Wu, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201656 · Cited by 1,063
MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
Sarkar, D., Liu, W., Xie, X., Anselmo, A. C., Mitragotri, S., & Banerjee, K. (2014) · ACS Nano · doi:10.1021/nn5009148 · Cited by 1,047
“org 3998 PBS solution, which is a standard procedure used for demonstrating the operation of FET-based biosensors.(2,3,7,45,49) It is to be noted that detection of biomolecules from whole blood using FET biosensors has already been demonstrated using a microfluidic purification chip.”
BackgroundMethodMaking it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
“, require far fewer target molecules, and protein detection on the femtomolar level has been reporte”
Background
Metadata
- Authors
- Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Fahmy, Tarek M.
- Reed, Mark A.
- Venue
- Nature
- Published
- 2007-02
- Volume
- 445
- Issue
- 7127
- Pages
- 519-522
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2077609143
- Cited by
- 1,352
- References
- 32
- Citations by year
- 2026: 17 · 2025: 19 · 2024: 37 · 2023: 29 · 2022: 32 · 2021: 49 · 2020: 51 · 2019: 47 · 2018: 58 · 2017: 49 · 2016: 86 · 2015: 92 · 2014: 93 · 2013: 118 · 2012: 124
- FWCI
- 76.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- semiconductor nanowires, field-effect transistor sensors, antibody detection, femtomolar sensitivity, pathogen detection, top-down nanowire fabrication, sensor integration
- MeSH terms
- Animals, Antibodies, Infections, Semiconductors, Sensitivity and Specificity, T-Lymphocytes, CD3 Complex, Mice, Nanowires
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.