CoChat

High-speed and high-efficiency travelling wave single-photon detectors embedded in nanophotonic circuits

Open access
Pernice, W.H.P., Schuck, C., Minaeva, O., Li, M., Goltsman, G.N., Sergienko, A.V., Tang, H.X. · 2012 · Nature Communications

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Abstract

Ultrafast, high-efficiency single-photon detectors are among the most sought-after elements in modern quantum optics and quantum communication. However, imperfect modal matching and finite photon absorption rates have usually limited their maximum attainable detection efficiency. Here we demonstrate superconducting nanowire detectors atop nanophotonic waveguides, which enable a drastic increase of the absorption length for incoming photons. This allows us to achieve high on-chip single-photon detection efficiency up to 91% at telecom wavelengths, repeatable across several fabricated chips. We also observe remarkably low dark count rates without significant compromise of the on-chip detection efficiency. The detectors are fully embedded in scalable silicon photonic circuits and provide ultrashort timing jitter of 18 ps. Exploiting this high temporal resolution, we demonstrate ballistic photon transport in silicon ring resonators. Our direct implementation of a high-performance single-photon detector on chip overcomes a major barrier in integrated quantum photonics. High-efficiency and high-speed single-photon detectors are vital for quantum optical technologies. Using superconducting nanowire detectors on nanophotonic waveguides, Pernice et al.demonstrate on-chip single-photon detection efficiencies up to 91% at telecommunications wavelengths.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms2307

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Design of the travelling wave SSPD. (a) Principle of the travelling wave SSPD: a sub-wavelength absorbing NbN nanowire is patterned atop a silicon waveguide to detect single photons. (b) Optical micrograph of a fabricated device showing the optical input circuitry, RF contact pads and the SSPD. The control and residual ports are used for calibration purposes. Inset: zoom into the detector region with an scanning electron microscope image showing the single loop device layout. Scale bar, 250 μm. (c) FDTD simulation of the absorption characteristics of the detector. The propagating intensity is displayed in a logarithmic scale. (d) The simulated field distribution of the optical mode in the silicon portion of the waveguide. (e) The modal pattern with NbN wires on top. The inset shows the optical field concentration around the NbN wires. (f) Measured absorption spectra of detectors with lengths varying from 5 to 40 μm in dependence of wavelength. (g) The detector attenuation in dependence of length, measured as the ratio of power between the residual port and the control port, exhibits a slope of 0.98 dB μm−1.
Figure 1 Design of the travelling wave SSPD. (a) Principle of the travelling wave SSPD: a sub-wavelength absorbing NbN nanowire is patterned atop a silicon waveguide to detect single photons. (b) Optical micrograph of a fabricated device showing the optical input circuitry, RF contact pads and the SSPD. The control and residual ports are used for calibration purposes. Inset: zoom into the detector region with an scanning electron microscope image showing the single loop device layout. Scale bar, 250 μm. (c) FDTD simulation of the absorption characteristics of the detector. The propagating intensity is displayed in a logarithmic scale. (d) The simulated field distribution of the optical mode in the silicon portion of the waveguide. (e) The modal pattern with NbN wires on top. The inset shows the optical field concentration around the NbN wires. (f) Measured absorption spectra of detectors with lengths varying from 5 to 40 μm in dependence of wavelength. (g) The detector attenuation in dependence of length, measured as the ratio of power between the residual port and the control port, exhibits a slope of 0.98 dB μm−1.CC BY-NC-ND · PubMed Central
Figure 2 SSPD on-chip detection performance. (a) OCDE of fabricated devices as a function of detector length and normalized biasing current, after correction for coupler and 50/50 splitter loss. The measured devices have meander widths between 70 and 100 nm. The best OCDE of 91% is obtained for a 20-μm long and 100-nm wide detector (detector III) at 99% of the critical current. For comparison, a meander-type detector (MMI) is also measured with a peak detection efficiency of 3%. Inset: a linear plot of the high-biasing current region, showing the monotonic increase of the detection efficiency towards Ic. The overall system efficiency of the devices, however, is reduced by the coupling loss at the input grating coupler and 50% intensity reduction at the 50/50 splitter. (b) The detector dark count rate measured as a function of biasing current for the grey curve in a (detector II). Shown are data for three different temperatures between 1.7 and 4 K. At 99% Ic, the minimum count rate is 50 Hz.
Figure 2 SSPD on-chip detection performance. (a) OCDE of fabricated devices as a function of detector length and normalized biasing current, after correction for coupler and 50/50 splitter loss. The measured devices have meander widths between 70 and 100 nm. The best OCDE of 91% is obtained for a 20-μm long and 100-nm wide detector (detector III) at 99% of the critical current. For comparison, a meander-type detector (MMI) is also measured with a peak detection efficiency of 3%. Inset: a linear plot of the high-biasing current region, showing the monotonic increase of the detection efficiency towards Ic. The overall system efficiency of the devices, however, is reduced by the coupling loss at the input grating coupler and 50% intensity reduction at the 50/50 splitter. (b) The detector dark count rate measured as a function of biasing current for the grey curve in a (detector II). Shown are data for three different temperatures between 1.7 and 4 K. At 99% Ic, the minimum count rate is 50 Hz.CC BY-NC-ND · PubMed Central
Figure 3 SPD characterization in time domain. (a) Measurement of the pulse shape for SSPDs with lengths varying from 10 to 40 μm after 64 averages. Discrete symbols indicate experimental data, and the solid lines are exponential fits to the decay of the detector. A decay time of 455 ps is obtained for the shortest detector. Inset: single shot measurement curve. The right side shows the initial slope of the pulse in dependence of detector length. (b) The extracted detector decay time as a function of the detector length. The decay time increases linearly with increasing detector length due to increased kinetic inductance. The error bars denote the fitting uncertainty to the exponential decay. (c) The timing jitter measured for a representative detector. Green symbols denote the jitter measured with the PicoHarp300, with an intrinsic instrument jitter of 19 ps. Blue symbols denote results obtained with a high-speed oscilloscope with an instrument timing jitter of <1 ps. (d) The timing jitter measured in dependence of amplifier bandwidth. Results converge towards 18.4 ps for an amplifier analogue bandwidth of ?10 GHz.
Figure 3 SPD characterization in time domain. (a) Measurement of the pulse shape for SSPDs with lengths varying from 10 to 40 μm after 64 averages. Discrete symbols indicate experimental data, and the solid lines are exponential fits to the decay of the detector. A decay time of 455 ps is obtained for the shortest detector. Inset: single shot measurement curve. The right side shows the initial slope of the pulse in dependence of detector length. (b) The extracted detector decay time as a function of the detector length. The decay time increases linearly with increasing detector length due to increased kinetic inductance. The error bars denote the fitting uncertainty to the exponential decay. (c) The timing jitter measured for a representative detector. Green symbols denote the jitter measured with the PicoHarp300, with an intrinsic instrument jitter of 19 ps. Blue symbols denote results obtained with a high-speed oscilloscope with an instrument timing jitter of <1 ps. (d) The timing jitter measured in dependence of amplifier bandwidth. Results converge towards 18.4 ps for an amplifier analogue bandwidth of ?10 GHz.CC BY-NC-ND · PubMed Central
Figure 4 Time-domain ring-down measurements. (a) An integrated photonic circuit with input grating couplers, a long micro-ring resonator and integrated SSPD. Scale bar, 250 μm. Inset: zoom into the detector region. (b) Schematic of the time-domain response of an overcoupled ring resonator. Measured results in the spectral domain reveal an optical quality factor of 14,000 as extracted from the Lorentzian fit to the resonance (solid line). (c) Schematic of the time-domain response of a weakly coupled ring resonator in the drop port. The measured optical Q in the frequency domain is 24,000, as determined from the Lorentzian fit (solid line). (d) The measured time-domain response for the overcoupled ring resonator. The length of the ring introduces a round-trip delay of 72.7 ps, whereas the circulating pulse amplitude decays with a time constant of 19.3 ps when travelling along the ring, as extracted from the exponential fit to the pulse peaks (solid line). Inset: the data displayed in log-scale reveals three consecutive pulses. (e) The measured time response of the undercoupled ring resonator. The device shows a decay time of 37.1 ps, obtained from the exponential fit to the pulse peaks (solid line). Because of the slower decay, four consecutive pulses are discernible in the log-plot (inset).
Figure 4 Time-domain ring-down measurements. (a) An integrated photonic circuit with input grating couplers, a long micro-ring resonator and integrated SSPD. Scale bar, 250 μm. Inset: zoom into the detector region. (b) Schematic of the time-domain response of an overcoupled ring resonator. Measured results in the spectral domain reveal an optical quality factor of 14,000 as extracted from the Lorentzian fit to the resonance (solid line). (c) Schematic of the time-domain response of a weakly coupled ring resonator in the drop port. The measured optical Q in the frequency domain is 24,000, as determined from the Lorentzian fit (solid line). (d) The measured time-domain response for the overcoupled ring resonator. The length of the ring introduces a round-trip delay of 72.7 ps, whereas the circulating pulse amplitude decays with a time constant of 19.3 ps when travelling along the ring, as extracted from the exponential fit to the pulse peaks (solid line). Inset: the data displayed in log-scale reveals three consecutive pulses. (e) The measured time response of the undercoupled ring resonator. The device shows a decay time of 37.1 ps, obtained from the exponential fit to the pulse peaks (solid line). Because of the slower decay, four consecutive pulses are discernible in the log-plot (inset).CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Research works printed but not linked: 1

  1. Hu X. Efficient superconducting-nanowire single-photon detectors and their applications in quantum optics, Ph.D. Thesis, Massachusetts Institute of Technology. (2011).

Cited by

Items 101–200 of 474

Metadata

Authors
Pernice, W. H. P., Schuck, C., Minaeva, O., Li, M., Goltsman, G. N., Sergienko, A. V., & Tang, H. X.
Affiliations
  • Yale University (US)
  • Boston University (US)
Corresponding author
Tang, H.X.
Venue
Nature Communications
Published
2012-12-27
Volume
3
Issue
1
Pages
1325-1325
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2113914108
Cited by
477
References
47
Citations by year
2026: 12 · 2025: 34 · 2024: 31 · 2023: 33 · 2022: 23 · 2021: 29 · 2020: 32 · 2019: 35 · 2018: 29 · 2017: 42 · 2016: 63 · 2015: 38 · 2014: 37 · 2013: 38 · 2012: 1
FWCI
23.30
Type
journal article
Language
en
Open access
Locations
  • Nature Communications (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • OpenBU (Boston University) (submittedVersion, cc-by)
  • arXiv (Cornell University)
Funders
Deutsche Forschungsgemeinschaft
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
Keywords
single-photon detectors, superconducting nanowire single-photon detectors, nanophotonic waveguides, silicon photonics, detection efficiency, dark count rate, timing jitter, silicon ring resonator, telecom wavelengths, integrated quantum photonics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.