The DOI matches its Crossref record.
Tuning Piezo ion channels to detect molecular-scale movements relevant for fine touch
Open accessAbstract
In sensory neurons, mechanotransduction is sensitive, fast and requires mechanosensitive ion channels. Here we develop a new method to directly monitor mechanotransduction at defined regions of the cell-substrate interface. We show that molecular-scale (~13 nm) displacements are sufficient to gate mechanosensitive currents in mouse touch receptors. Using neurons from knockout mice, we show that displacement thresholds increase by one order of magnitude in the absence of stomatin-like protein 3 (STOML3). Piezo1 is the founding member of a class of mammalian stretch-activated ion channels, and we show that STOML3, but not other stomatin-domain proteins, brings the activation threshold for Piezo1 and Piezo2 currents down to ~10 nm. Structure–function experiments localize the Piezo modulatory activity of STOML3 to the stomatin domain, and higher-order scaffolds are a prerequisite for function. STOML3 is the first potent modulator of Piezo channels that tunes the sensitivity of mechanically gated channels to detect molecular-scale stimuli relevant for fine touch. The stomatin domain protein STOML3 is required for the sensation of touch. Here, Poole et al.show that STOML3 enhances the activity of mechanosensitive Piezo1 and Piezo2 ion channels by reducing their activation thresholds, and that it achieves this through its stomatin domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
Endothelial cation channel PIEZO1 controls blood pressure by mediating flow-induced ATP release
Wang, S., Chennupati, R., Kaur, H., Iring, A., Wettschureck, N., & Offermanns, S. (2016) · Journal of Clinical Investigation · doi:10.1172/jci87343 · Cited by 616
Piezos thrive under pressure: mechanically activated ion channels in health and disease
Murthy, S. E., Dubin, A. E., & Patapoutian, A. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.92 · Cited by 582
Cox, C. D., Bae, C., Ziegler, L., Hartley, S., Nikolova-Krstevski, V., Rohde, P. R., Ng, C.-A., Sachs, F., Gottlieb, P. A., & Martinac, B. (2016) · Nature Communications · doi:10.1038/ncomms10366 · Cited by 528
Structure-based membrane dome mechanism for Piezo mechanosensitivity
Guo, Y. R., & MacKinnon, R. (2017) · eLife · doi:10.7554/elife.33660 · Cited by 446
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Piezo Proteins: Regulators of Mechanosensation and Other Cellular Processes
Bagriantsev, S. N., Gracheva, E. O., & Gallagher, P. G. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.r114.612697 · Cited by 249
Force Sensing by Piezo Channels in Cardiovascular Health and Disease
Beech, D. J., & Kalli, A. C. (2019) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.119.313348 · Cited by 242
Voltage gating of mechanosensitive PIEZO channels
Moroni, M., Servin-Vences, M. R., Fleischer, R., Sánchez-Carranza, O., & Lewin, G. R. (2018) · Nature Communications · doi:10.1038/s41467-018-03502-7 · Cited by 200
Self-citationDuchemin, A.-L., Vignes, H., & Vermot, J. (2019) · eLife · doi:10.7554/elife.44706 · Cited by 170
Tang, H., Zeng, R., He, E., Zhang, I., Ding, C., & Zhang, A. (2022) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.2c00085 · Cited by 120
Metadata
- Authors
- Poole, K., Herget, R., Lapatsina, L., Ngo, H.-D., & Lewin, G. R.
- Venue
- Nature Communications
- Published
- 2014-03-24
- Volume
- 5
- Issue
- 1
- Pages
- 3520-3520
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W1990815583
- Cited by
- 293
- References
- 0
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.