Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Over 7 million people worldwide die annually from erratic heart rhythms (cardiac arrhythmias), and many more are disabled. Yet there is no imaging modality to identify patients at risk, provide accurate diagnosis and guide therapy. Standard diagnostic techniques such as the electrocardiogram (ECG) provide only low-resolution projections of cardiac electrical activity on the body surface. Here we demonstrate the successful application in humans of a new imaging modality called electrocardiographic imaging (ECGI), which noninvasively images cardiac electrical activity in the heart. In ECGI, a multielectrode vest records 224 body-surface electrocardiograms; electrical potentials, electrograms and isochrones are then reconstructed on the heart's surface using geometrical information from computed tomography (CT) and a mathematical algorithm. We provide examples of ECGI application during atrial and ventricular activation and ventricular repolarization in (i) normal heart (ii) heart with a conduction disorder (right bundle branch block) (iii) focal activation initiated by right or left ventricular pacing, and (iv) atrial flutter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BSPM has nowadays got a real clinical breakthrough as a method for non-invasive 3D EAI, with the competitive concept of “ECG imaging” (ECGi) (239–241), a technology that has rapidly evolved in clinically available devices (242), increasingly used for non-invasive pre-interventional assessment of patients undergoing catheter ablation procedures (243, 244).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [239]
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Total Excitation of the Isolated Human Heart
DURRER, D., VAN DAM, R. T., FREUD, G. E., JANSE, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,777
Janse, M. J., & Wit, A. L. (1989) · Physiological Reviews · doi:10.1152/physrev.1989.69.4.1049 · Cited by 1,018
Haws, C. W., & Lux, R. L. (1990) · Circulation · doi:10.1161/01.cir.81.1.281 · Cited by 397
Ionic Current Basis of Electrocardiographic Waveforms: A Model Study
Gima, K., & Rudy, Y. (2002) · Circulation Research · doi:10.1161/01.res.0000016960.61087.86 · Cited by 396 · cited 1×
“Normal repolarization potential patterns have no direct relationship to depolarization patterns because the T-wave is determined mostly by local intrinsic repolarization propertie”
BackgroundSelf-citationSOSA, E., SCANAVACCA, M., D'AVILA, A., PICCIONI, J., SANCHEZ, O., VELARDE, J. L., SILVA, M., & REOLÃO, B. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00907.x · Cited by 330 · cited 1×
“More than a third of clinical ventricular tachycardia cases involve the subepicardium, an observation that led to the development of transthoracic epicardial ablation to treat ventricular tachycardi”
BackgroundOster, H. S., Taccardi, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1997) · Circulation · doi:10.1161/01.cir.96.3.1012 · Cited by 256
Self-citationOster, H. S., TACCARDI, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1998) · Circulation · doi:10.1161/01.cir.97.15.1496 · Cited by 140
Self-citationEpicardial activation of the intact human heart without conduction defect.
Wyndham, C. R. C., Meeran, M. K., Smith, T., Saxena, A., Engelman, R. M., Levitsky, S., & Rosen, K. M. (1979) · Circulation · doi:10.1161/01.cir.59.1.161 · Cited by 127
A Noninvasive Imaging Modality for Cardiac Arrhythmias
Burnes, J. E., TACCARDI, B., & Rudy, Y. (2000) · Circulation · doi:10.1161/01.cir.102.17.2152 · Cited by 125
Self-citation
Research works printed but not linked: 1
- Biermann, M. et al. The interpretation of cardiac electrograms. in Cardiac Mapping (eds. Shenasa, M., Borggrefe, M. & Breithardt, G.) 15–39 (Futura Publishing, Mount Kisco, New York, 2003).
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
“A mathematical algorithm combines the body surface potentials recorded by the electrodes and the geometric information provided by CT and solves the electrocardiographic inverse problem in order to noninvasively obtain estimated epicardial electrograms.(221,570) An advantage of this approach is that it is noninvasive,…”
MethodTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Driver domains in persistent atrial fibrillation
Haissaguerre, M., Hocini, M., Denis, A., Shah, A. J., Komatsu, Y., Yamashita, S., Daly, M., Amraoui, S., Zellerhoff, S., Picat, M.-Q., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005421 · Cited by 734
Metadata
- Authors
- Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Rudy, Yoram
- ORCID
- Venue
- Nature Medicine
- Published
- 2004-03-14
- Volume
- 10
- Issue
- 4
- Pages
- 422-428
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- PMC
- PMC1950745
- OpenAlex
- W2064569583
- Cited by
- 646
- References
- 29
- Citations by year
- 2026: 6 · 2025: 18 · 2024: 35 · 2023: 19 · 2022: 24 · 2021: 42 · 2020: 30 · 2019: 39 · 2018: 36 · 2017: 44 · 2016: 28 · 2015: 32 · 2014: 38 · 2013: 35 · 2012: 33
- FWCI
- 17.51
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Heart, Lung, and Blood Institute (R01HL049054, R37HL033343)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- electrocardiographic imaging, cardiac electrophysiology, cardiac arrhythmias, noninvasive cardiac imaging, surface electrocardiogram, isochrone mapping, right bundle branch block, ventricular repolarization, atrial flutter, ventricular pacing, atrial activation, ventricular activation
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Heart, Heart Atria, Heart Ventricles, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.