The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Whole-cell 3D STORM reveals interactions between cellular structures with nanometer-scale resolution
Open accessAbstract
The ability to directly visualize nanoscopic cellular structures and their spatial relationship in all three dimensions will greatly enhance our understanding of molecular processes in cells. Here we demonstrated multicolor three-dimensional (3D) stochastic optical reconstruction microscopy (STORM) as a tool to quantitatively probe cellular structures and their interactions. To facilitate STORM imaging, we generated photoswitchable probes in several distinct colors by covalently linking a photoswitchable cyanine reporter and an activator molecule to assist bioconjugation. We performed 3D localization in conjunction with focal plane scanning and correction for refractive index mismatch to obtain whole-cell images with a spatial resolution of 20–30 nm and 60–70 nm in the lateral and axial dimensions, respectively. Using this approach, we imaged the entire mitochondrial network in fixed monkey kidney BS-C-1 cells, and studied the spatial relationship between mitochondria and microtubules. The 3D STORM images resolved mitochondrial morphologies as well as mitochondria-microtubule contacts that were obscured in conventional fluorescence images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Mitotic phosphorylation of dynamin-related GTPase Drp1 participates in mitochondrial fission.
Taguchi, N., Ishihara, N., Jofuku, A., Oka, T., & Mihara, K. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m607279200 · Cited by 1,226
Boldogh, I. R., & Pon, L. A. (2007) · Trends in Cell Biology · doi:10.1016/j.tcb.2007.07.008 · Cited by 270
Cited by
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Self-citationChen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501
Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging
Dempsey, G. T., Vaughan, J. C., Chen, K. H., Bates, M., & Zhuang, X. (2011) · Nature Methods · doi:10.1038/nmeth.1768 · Cited by 1,369
Self-citationA guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Super-resolution microscopy with DNA-PAINT
Schnitzbauer, J., Strauss, M. T., Schlichthaerle, T., Schueder, F., & Jungmann, R. (2017) · Nature Protocols · doi:10.1038/nprot.2017.024 · Cited by 1,047
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Chromatin Fibers Are Formed by Heterogeneous Groups of Nucleosomes In Vivo
Ricci, M. A., Manzo, C., García-Parajo, M. F., Lakadamyali, M., & Cosma, M. P. (2015) · Cell · doi:10.1016/j.cell.2015.01.054 · Cited by 736
Isotropic three-dimensional super-resolution imaging with a self-bending point spread function
Jia, S., Vaughan, J. C., & Zhuang, X. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.13 · Cited by 542
Self-citationSuper-Resolution Fluorescence Imaging of Telomeres Reveals TRF2-Dependent T-loop Formation
Doksani, Y., Wu, J. Y., de Lange, T., & Zhuang, X. (2013) · Cell · doi:10.1016/j.cell.2013.09.048 · Cited by 493
Self-citationPrecisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
York, A. G., Parekh, S. H., Nogare, D. D., Fischer, R. S., Temprine, K., Mione, M., Chitnis, A. B., Combs, C. A., & Shroff, H. (2012) · Nature Methods · doi:10.1038/nmeth.2025 · Cited by 472
Organization and Function of Membrane Contact Sites
Helle, S. C. J., Kanfer, G., Kolar, K., Lang, A., Michel, A. H., & Kornmann, B. (2013) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2013.01.028 · Cited by 453
QuickPALM: 3D real-time photoactivation nanoscopy image processing in ImageJ
Henriques, R., Lelek, M., Fornasiero, E. F., Valtorta, F., Zimmer, C., & Mhlanga, M. M. (2010) · Nature Methods · doi:10.1038/nmeth0510-339 · Cited by 411
Virus cell-to-cell transmission
Mothes, W., Sherer, N. M., Jin, J., & Zhong, P. (2010) · Journal of Virology · doi:10.1128/jvi.00443-10 · Cited by 353
Fluorophore localization algorithms for super-resolution microscopy
Small, A., & Stahlheber, S. (2014) · Nature Methods · doi:10.1038/nmeth.2844 · Cited by 349
Photophysical processes in single molecule organic fluorescent probes
Stennett, E. M. S., Ciuba, M. A., & Levitus, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60211g · Cited by 323
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Molecular genetics and imaging technologies for circuit-based neuroanatomy
Arenkiel, B. R., & Ehlers, M. D. (2009) · Nature · doi:10.1038/nature08536 · Cited by 78
Mitochondrial dynamics in aging and disease
Bereiter-Hahn, J. (2014) · Progress in molecular biology and translational science · doi:10.1016/b978-0-12-394625-6.00004-0 · Cited by 48
Metadata
- Authors
- Huang, B., Jones, S. A., Brandenburg, B., & Zhuang, X.
- Venue
- Nature Methods
- Published
- 2008-11-23
- Volume
- 5
- Issue
- 12
- Pages
- 1047-1052
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2162298934
- Cited by
- 609
- References
- 3
- FWCI
- 19.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.