The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Highly stretchable electric circuits from a composite material of silver nanoparticles and elastomeric fibres
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Percolation Theory
Stauffer, D., Aharony, A., & Redner, S. (1993) · Physics Today · doi:10.1063/1.2808877 · Cited by 6,666
Chen, Z., Ren, W., Gao, L., Liu, B., Pei, S., & Cheng, H.-M. (2011) · Nature Materials · doi:10.1038/nmat3001 · Cited by 3,834
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
An introduction to percolation theory
Shante, V. K. S., & Kirkpatrick, S. (1971) · Advances in Physics · doi:10.1080/00018737100101261 · Cited by 2,491
Bowden, N., Brittain, S., Evans, A. G., Hutchinson, J. W., & Whitesides, G. M. (1998) · Nature · doi:10.1038/30193 · Cited by 2,305
Stretchable active-matrix organic light-emitting diode display using printable elastic conductors
Sekitani, T., Nakajima, H., Maeda, H., Fukushima, T., Aida, T., Hata, K., & Someya, T. (2009) · Nature Materials · doi:10.1038/nmat2459 · Cited by 1,767
A Stretchable Form of Single-Crystal Silicon for High-Performance Electronics on Rubber Substrates
Khang, D.-Y., Jiang, H., Huang, Y., & Rogers, J. A. (2006) · Science · doi:10.1126/science.1121401 · Cited by 1,689
Stretchable, Porous, and Conductive Energy Textiles
Hu, L., Pasta, M., La Mantia, F., Cui, L., Jeong, S., Deshazer, H. D., Choi, J. W., Han, S. M., & Cui, Y. (2010) · Nano Letters · doi:10.1021/nl903949m · Cited by 1,475
Kim, Y. H., Sachse, C., Machala, M. L., May, C., Müller‐Meskamp, L., & Leo, K. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002290 · Cited by 1,458
Cited by
Items 101–107 of 107
Smart Bandage With Wireless Strain and Temperature Sensors and Batteryless NFC Tag
Escobedo, P., Bhattacharjee, M., Nikbakhtnasrabadi, F., & Dahiya, R. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3048282 · Cited by 209
An Intrinsically Stretchable Nanowire Photodetector with a Fully Embedded Structure
Yan, C., Wang, J., Wang, X., Kang, W., Cui, M., Foo, C. Y., & Lee, P. S. (2014) · Advanced Materials · doi:10.1002/adma.201304226 · Cited by 191
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400209 · Cited by 169
A bioinspired analogous nerve towards artificial intelligence
Liao, X., Song, W., Zhang, X., Yan, C., Li, T., Ren, H., Liu, C., Wang, Y., & Zheng, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-14214-x · Cited by 153
A Bioinspired Stretchable Sensory‐Neuromorphic System
Kim, S. H., Baek, G. W., Yoon, J., Seo, S., Park, J., Hahm, D., Chang, J. H., Seong, D., Seo, H., Oh, S., et al. (2021) · Advanced Materials · doi:10.1002/adma.202104690 · Cited by 142
Self-citationLee, H., Kwon, D., Cho, H., Park, I., & Kim, J. (2017) · Scientific Reports · doi:10.1038/srep39837 · Cited by 130
Self-citationJason, N. N., Wang, S. J., Bhanushali, S., & Cheng, W. (2016) · Nanoscale · doi:10.1039/c6nr04056j · Cited by 64
Metadata
- Authors
- Park, M., Im, J., Shin, M., Min, Y., Park, J., Cho, H., Park, S., Shim, M.-B., Jeon, S., Chung, D.-Y., Bae, J., Park, J., Jeong, U., & Kim, K.
- Venue
- Nature Nanotechnology
- Published
- 2012-11-25
- Volume
- 7
- Issue
- 12
- Pages
- 803-809
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2009865360
- Cited by
- 919
- References
- 29
- FWCI
- 26.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.