The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A scanning superconducting quantum interference device with single electron spin sensitivity
Open accessAbstract
Superconducting quantum interference devices (SQUIDs) can be used to detect weak magnetic fields and have traditionally been the most sensitive magnetometers available. However, because of their relatively large effective size (on the order of 1 µm), the devices have so far been unable to achieve the level of sensitivity required to detect the field generated by the spin magnetic moment (μB) of a single electron. Here we show that nanoscale SQUIDs with diameters as small as 46 nm can be fabricated on the apex of a sharp tip. The nano-SQUIDs have an extremely low flux noise of 50 nΦ0 Hz(-1/2) and a spin sensitivity of down to 0.38 μB Hz(-1/2), which is almost two orders of magnitude better than previous devices. They can also operate over a wide range of magnetic fields, providing a sensitivity of 0.6 μB Hz(-1/2) at 1 T. The unique geometry of our nano-SQUIDs makes them well suited to scanning probe microscopy, and we use the devices to image vortices in a type II superconductor, spaced 120 nm apart, and to record magnetic fields due to alternating currents down to 50 nT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Likharev, K. K. (1979) · Reviews of Modern Physics · doi:10.1103/revmodphys.51.101 · Cited by 1,638
Single spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
A robust scanning diamond sensor for nanoscale imaging with single nitrogen-vacancy centres
Maletinsky, P., Hong, S., Grinolds, M. S., Hausmann, B., Lukin, M. D., Walsworth, R. L., Loncar, M., & Yacoby, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.50 · Cited by 726
dc SQUID: Noise and optimization
Tesche, C. D., & Clarke, J. (1977) · Journal of Low Temperature Physics · doi:10.1007/bf00655097 · Cited by 691
Carbon nanotube superconducting quantum interference device
Cleuziou, J.-P., Wernsdorfer, W., Bouchiat, V., Ondarçuhu, T., & Monthioux, M. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.54 · Cited by 583
The SQUID Handbook: Applications of SQUIDs and SQUID Systems
(2006) · doi:10.1002/9783527609956 · Cited by 512
Dispersive magnetometry with a quantum limited SQUID parametric amplifier
Hatridge, M., Vijay, R., Slichter, D. H., Clarke, J., & Siddiqi, I. (2011) · Physical Review B · doi:10.1103/physrevb.83.134501 · Cited by 266
Nanoscale magnetic field mapping with a single spin scanning probe magnetometer
Rondin, L., Tetienne, J.-P., Spinicelli, P., Dal Savio, C., Karrai, K., Dantelle, G., Thiaville, A., Rohart, S., Roch, J.-F., & Jacques, V. (2012) · Applied Physics Letters · doi:10.1063/1.3703128 · Cited by 228
The SQUID Handbook: Fundamentals and Technology of SQUIDs and SQUID Systems
Clarke, J. L., & Braginski, A. I. (2004) · Cited by 215
Mechanics of individual isolated vortices in a cuprate superconductor
Auslaender, O. M., Luan, L., Straver, E. W. J., Hoffman, J. E., Koshnick, N. C., Zeldov, E., Bonn, D. A., Liang, R., Hardy, W. N., & Moler, K. A. (2009) · Nature Physics · doi:10.1038/nphys1127 · Cited by 204
Self-citationGradiometric micro-SQUID susceptometer for scanning measurements of mesoscopic samples
Huber, M. E., Koshnick, N. C., Bluhm, H., Archuleta, L. J., Azua, T., Björnsson, P. G., Gardner, B. W., Halloran, S. T., Lucero, E. A., & Moler, K. A. (2008) · Review of Scientific Instruments · doi:10.1063/1.2932341 · Cited by 171
Self-citationFundamental studies of superconductors using scanning magnetic imaging
Kirtley, J. R. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/12/126501 · Cited by 171
High-dynamic-range magnetometry with a single nuclear spin in diamond
Waldherr, G., Beck, J., Neumann, P., Said, R. S., Nitsche, M., Markham, M., Twitchen, D. J., Twamley, J., Jelezko, F., & Wrachtrup, J. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.224 · Cited by 152
Hao, L., Macfarlane, J. C., Gallop, J. C., Cox, D., Beyer, J., Drung, D., & Schurig, T. (2008) · Applied Physics Letters · doi:10.1063/1.2917580 · Cited by 140
Low-noise modular microsusceptometer using nearly quantum limited dc SQUIDs
Awschalom, D. D., Rozen, J. R., Ketchen, M. B., Gallagher, W. J., Kleinsasser, A. W., Sandstrom, R. L., & Bumble, B. (1988) · Applied Physics Letters · doi:10.1063/1.100291 · Cited by 127
High-dynamic-range magnetometry with a single electronic spin in diamond
Nusran, N., Momeen, M. U., & Dutt, M. V. G. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.225 · Cited by 94
DC SQUID series array amplifiers with 120 MHz bandwidth
Huber, M. E., Neil, P. A., Benson, R. G., Burns, D. A., Corey, A. M., Flynn, C., Kitaygorodskaya, Y., Massihzadeh, O., Martinis, J. M., & Hilton, G. C. (2001) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.919577 · Cited by 61
Self-citation
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Magnetometry with nitrogen-vacancy defects in diamond
Rondin, L., Tetienne, J.-P., Hingant, T., Roch, J.-F., Maletinsky, P., & Jacques, V (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/5/056503 · Cited by 1,336
Probing condensed matter physics with magnetometry based on nitrogen-vacancy centres in diamond
Casola, F., van der Sar, T., & Yacoby, A. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.88 · Cited by 635
Knolle, J., & Moessner, R. (2019) · Annual Review of Condensed Matter Physics · doi:10.1146/annurev-conmatphys-031218-013401 · Cited by 541
The Magnetic Genome of Two-Dimensional van der Waals Materials
Wang, Q. H., Bedoya-Pinto, A., Blei, M., Dismukes, A. H., Hamo, A., Jenkins, S., Koperski, M., Liu, Y., Sun, Q.-C., Telford, E. J., et al. (2022) · ACS Nano · doi:10.1021/acsnano.1c09150 · Cited by 496
Metadata
- Authors
- Vasyukov, D., Anahory, Y., Embon, L., Halbertal, D., Cuppens, J., Neeman, L., Finkler, A., Segev, Y., Myasoedov, Y., Rappaport, M. L., Huber, M. E., & Zeldov, E.
- Venue
- Nature Nanotechnology
- Published
- 2013-09
- Volume
- 8
- Issue
- 9
- Pages
- 639-644
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2074918043
- Cited by
- 421
- References
- 18
- FWCI
- 15.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.