The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Interferometric synthetic aperture microscopy
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
Spotlight-Mode Synthetic Aperture Radar: A Signal Processing Approach
Jakowatz, C. V., Wahl, D. E., Eichel, P. H., Ghiglia, D. C., & Thompson, P. A. (1996) · Springer eBooks · doi:10.1007/978-1-4613-1333-5 · Cited by 1,193
The Nuclear Induction Experiment
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.70.474 · Cited by 1,192
Helgason, S. (1999) · Progress in Mathematics · doi:10.1007/978-1-4757-1463-0 · Cited by 1,166
Optical Projection Tomography as a Tool for 3D Microscopy and Gene Expression Studies
Sharpe, J., Ahlgren, U., Perry, P., Hill, B., Ross, A., Hecksher-Sørensen, J., Baldock, R., & Davidson, D. (2002) · Science · doi:10.1126/science.1068206 · Cited by 1,158
Cited by
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Self-citationBiomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Self-citationLiu, L., Gardecki, J. A., Nadkarni, S. K., Toussaint, J. D., Yagi, Y., Bouma, B. E., & Tearney, G. J. (2011) · Nature Medicine · doi:10.1038/nm.2409 · Cited by 463
Nano-optic endoscope for high-resolution optical coherence tomography in vivo
Pahlevaninezhad, H., Khorasaninejad, M., Huang, Y.-W., Shi, Z., Hariri, L. P., Adams, D. C., Ding, V., Zhu, A., Qiu, C.-W., Capasso, F., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0224-2 · Cited by 412
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Nguyen, F. T., Zysk, A. M., Chaney, E. J., Kotynek, J. G., Oliphant, U. J., Bellafiore, F. J., Rowland, K. M., Johnson, P. A., & Boppart, S. A. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4340 · Cited by 387
Self-citationDubois, A., Levecq, O., Azimani, H., Siret, D., Barut, A., Suppa, M., del Marmol, V., Malvehy, J., Cinotti, E., Rubegni, P., et al. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.10.106007 · Cited by 269
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Gradient light interference microscopy for 3D imaging of unlabeled specimens
Nguyen, T. H., Kandel, M. E., Rubessa, M., Wheeler, M. B., & Popescu, G. (2017) · Nature Communications · doi:10.1038/s41467-017-00190-7 · Cited by 259
Synthetic aperture-based on-chip microscopy
Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.34 · Cited by 257
Metadata
- Authors
- Ralston, T. S., Marks, D. L., Scott Carney, P., & Boppart, S. A.
- Venue
- Nature Physics
- Published
- 2007-01-21
- Volume
- 3
- Issue
- 2
- Pages
- 129-134
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2168020664
- Cited by
- 408
- References
- 24
- FWCI
- 11.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.