The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Electrical stimulation systems for cardiac tissue engineering
Open accessAbstract
We describe a protocol for tissue engineering of synchronously contractile cardiac constructs by culturing cardiac cells with the application of pulsatile electrical fields designed to mimic those present in the native heart. Tissue culture is conducted in a customized chamber built to allow for cultivation of (i) engineered three-dimensional (3D) cardiac tissue constructs, (ii) cell monolayers on flat substrates or (iii) cells on patterned substrates. This also allows for analysis of the individual and interactive effects of pulsatile electrical field stimulation and substrate topography on cell differentiation and assembly. The protocol is designed to allow for delivery of predictable electrical field stimuli to cells, monitoring environmental parameters, and assessment of cell and tissue responses. The duration of the protocol is 5 d for two-dimensional cultures and 10 d for 3D cultures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Radisic, M., Park, H., Shing, H., Consi, T., Schoen, F. J., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407817101 · Cited by 910
Self-citationTopographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Cell guidance by ultrafine topography in vitro
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1991) · Journal of Cell Science · doi:10.1242/jcs.99.1.73 · Cited by 491
Graham, L., & Orenstein, J. M. (2007) · Nature Protocols · doi:10.1038/nprot.2007.304 · Cited by 399
Song, B., Gu, Y., Pu, J., Reid, B., Zhao, Z., & Zhao, M. (2007) · Nature Protocols · doi:10.1038/nprot.2007.205 · Cited by 335
Medium perfusion enables engineering of compact and contractile cardiac tissue
Radisic, M., Yang, L., Boublik, J., Cohen, R. J., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00171.2003 · Cited by 332
Self-citationBiomimetic Approach to Cardiac Tissue Engineering: Oxygen Carriers and Channeled Scaffolds
Radisic, M., Park, H., Chen, F., Salazar-Lazzaro, J. E., Wang, Y., Dennis, R., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2077 · Cited by 325
Self-citationPerfusion Improves Tissue Architecture of Engineered Cardiac Muscle
Carrier, R. L., Rupnick, M., Langer, R., Schoen, F. J., Freed, L. E., & Vunjak-Novakovic, G. (2002) · Tissue Engineering · doi:10.1089/107632702753724950 · Cited by 323
Self-citationEmbryonic fibroblast motility and orientation can be influenced by physiological electric fields.
Erickson, C. A., & Nuccitelli, R. (1984) · The Journal of cell biology · doi:10.1083/jcb.98.1.296 · Cited by 320
Nishimura, K. Y., Isseroff, R. R., & Nuccitelli, R. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.1.199 · Cited by 302
Shen, Y. H., Shoichet, M. S., & Radisic, M. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.12.011 · Cited by 289
Self-citationCardiac tissue engineering using perfusion bioreactor systems
Radisic, M., Marsano, A., Maidhof, R., Wang, Y., & Vunjak-Novakovic, G. (2008) · Nature Protocols · doi:10.1038/nprot.2008.40 · Cited by 273
Self-citationBursac, N., Parker, K. K., Iravanian, S., & Tung, L. (2002) · Circulation Research · doi:10.1161/01.res.0000047530.88338.eb · Cited by 268
Mitcheson, J. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00128-x · Cited by 251
The Biomedical Engineering Handbook: Second Edition.
Onaral, B. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.sec6 · Cited by 246
Olivetti, G., Anversa, P., & Loud, A. V. (1980) · Circulation Research · doi:10.1161/01.res.46.4.503 · Cited by 213
Influence of the surface structure of titanium materials on the adhesion of fibroblasts
Eisenbarth, E., Meyle, J., Nachtigall, W., & Breme, J. (1996) · Biomaterials · doi:10.1016/0142-9612(96)87281-4 · Cited by 200
Au, H. T. H., Cheng, I., Chowdhury, M. F., & Radisic, M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.001 · Cited by 197
Self-citationBiomimetic approach to cardiac tissue engineering
Radisic, M., Park, H., Gerecht, S., Cannizzaro, C., Langer, R., & Vunjak-Novakovic, G. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2121 · Cited by 168
Self-citationNon-invasive measurement of bioelectric currents with a vibrating probe
Reid, B., Nuccitelli, R., & Zhao, M. (2007) · Nature Protocols · doi:10.1038/nprot.2007.91 · Cited by 146
Endogenous ionic currents and DC electric fields in multicellular animal tissues
Nuccitelli, R. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130714 · Cited by 129
Effects of electrical stimulation in C2C12 muscle constructs
Park, H., Bhalla, R., Saigal, R., Radisic, M., Watson, N., Langer, R., & Vunjak‐Novakovic, G. (2008) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.93 · Cited by 123
Self-citationControl of neural crest cell dispersion in the trunk of the avian embryo
Erickson, C. A. (1985) · Developmental Biology · doi:10.1016/0012-1606(85)90442-7 · Cited by 122
Berger, H. J. C., Prasad, S. K., Davidoff, A. J., Pimental, D. R., Ellingsen, Ø., Marsh, J. D., Smith, T. W., & Kelly, R. A. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.266.1.h341 · Cited by 120
Longevity of adult ventricular rat heart muscle cells in serum-free primary culture
Volz, A. (1991) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(91)90103-s · Cited by 114
Feld, Y., Melamed‐Frank, M., Kehat, I., et al. (2002) · Circulation · doi:10.1161/hc0402.102661 · Cited by 107
Adult rat ventricular myocytes cultured in defined medium: phenotype and electromechanical function
Ellingsen, Ø., Davidoff, A. J., Prasad, S. K., Berger, H. J. C., Springhorn, J. P., Marsh, J. D., Kelly, R. A., & Smith, T. W. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.265.2.h747 · Cited by 105
Chondrocyte Translocation Response to Direct Current Electric Fields
Chao, P. G., Roy, R., Mauck, R. L., Liu, W. F., Valhmu, W. B., & Hung, C. T. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.429661 · Cited by 93
Self-citationNorlin, A., Pan, J., & Leygraf, C. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1842092 · Cited by 80
Motor protein control of ion flux is an early step in embryonic left–right asymmetry
Levin, M. G. (2003) · BioEssays · doi:10.1002/bies.10339 · Cited by 62
Electric Stimulation of Excitable Tissue
Durand, D. M. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.ch17 · Cited by 61
Structure-Related Initiation of Reentry by Rapid Pacing in Monolayers of Cardiac Cells
Bian, W., & Tung, L. (2006) · Circulation Research · doi:10.1161/01.res.0000209770.72203.01 · Cited by 60
Sathaye, A., Bursac, N., Sheehy, S. P., & Tung, L. (2006) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2006.06.076 · Cited by 59
Mechanoelectrical excitation by fluid jets in monolayers of cultured cardiac myocytes
Kong, C.-R., Bursac, N., & Tung, L. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01084.2004 · Cited by 46
Practical Aspects of Cardiac Tissue Engineering With Electrical Stimulation
Cannizzaro, C., Tandon, N. M., Figallo, E., Park, H., Gerecht, S., Radisic, M., Elvassore, N., & Vunjak‐Novakovic, G. (2007) · Methods in molecular medicine · doi:10.1007/978-1-59745-443-8_16 · Cited by 46
Self-citationAn electro-tensile bioreactor for 3-D culturing of cardiomyocytes
Feng, Z., Matsumoto, T., Nomura, Y., & Nakamura, T. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1463399 · Cited by 42
Design of electrical stimulation bioreactors for cardiac tissue engineering
Tandon, N., Marsano, A., Cannizzaro, C., Joel Voldman, B., & Vunjak‐Novakovic, G. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649983 · Cited by 38
Self-citationCharacterization of Electrical Stimulation Electrodes for Cardiac Tissue Engineering
Tandon, N. M., Cannizzaro, C., Figallo, E., Joel Voldman, B., & Vunjak‐Novakovic, G. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259747 · Cited by 36
Self-citationHart, R. A., & Gandhi, O. P. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/10/027 · Cited by 34
Effects of electric fields on cytoskeleton of corneal stromal fibroblasts
Soong, H. K., Parkinson, W. C., Sulik, G. L., & Bafna, S. (1990) · Current Eye Research · doi:10.3109/02713689008999561 · Cited by 21
Loe, M. J., & Edwards, W. D. (2004) · Cardiovascular Pathology · doi:10.1016/j.carpath.2004.05.001 · Cited by 15
Biologists abandon Popper at their peril
(2000) · doi:10.1002/(sici)1521-1878(200002)22:2
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Self-citationBioprinting 3D microfibrous scaffolds for engineering endothelialized myocardium and heart-on-a-chip
Zhang, Y. S., Arneri, A., Bersini, S., Shin, S.-R., Zhu, K., Goli-Malekabadi, Z., Aleman, J., Colosi, C., Busignani, F., Dell'Erba, V., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.003 · Cited by 951
Carbon-Nanotube-Embedded Hydrogel Sheets for Engineering Cardiac Constructs and Bioactuators
Shin, S. R., Jung, S. M., Zalabany, M., Kim, K., Zorlutuna, P., Kim, S. B., Nikkhah, M., Khabiry, M., Azize, M., Kong, J., et al. (2013) · ACS Nano · doi:10.1021/nn305559j · Cited by 946
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Metadata
- Authors
- Tandon, N., Cannizzaro, C., Chao, P.-H. G., Maidhof, R., Marsano, A., Au, H. T. H., Radisic, M., & Vunjak-Novakovic, G.
- Venue
- Nature Protocols
- Published
- 2009-01-22
- Volume
- 4
- Issue
- 2
- Pages
- 155-173
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W2158442971
- Cited by
- 528
- References
- 44
- FWCI
- 27.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.