Looking at sound: optoacoustics with all-optical ultrasound detection
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Originally developed for diagnostic ultrasound imaging, piezoelectric transducers are the most widespread technology employed in optoacoustic (photoacoustic) signal detection. However, the detection requirements of optoacoustic sensing and imaging differ from those of conventional ultrasonography and lead to specifications not sufficiently addressed by piezoelectric detectors. Consequently, interest has shifted to utilizing entirely optical methods for measuring optoacoustic waves. All-optical sound detectors yield a higher signal-to-noise ratio per unit area than piezoelectric detectors and feature wide detection bandwidths that may be more appropriate for optoacoustic applications, enabling several biomedical or industrial applications. Additionally, optical sensing of sound is less sensitive to electromagnetic noise, making it appropriate for a greater spectrum of environments. In this review, we categorize different methods of optical ultrasound detection and discuss key technology trends geared towards the development of all-optical optoacoustic systems. We also review application areas that are enabled by all-optical sound detectors, including interventional imaging, non-contact measurements, magnetoacoustics, and non-destructive testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Kersey, A. D., Davis, M. A., Patrick, H. J., LeBlanc, M., Koo, K. P., Askins, C. G., Putnam, M. A., & Friebele, E. J. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618377 · Cited by 3,599
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Advances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
Self-citationAmerican National Standard for the Safe Use of Lasers.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-82-1-132_2 · Cited by 498
Light In and Sound Out: Emerging Translational Strategies for Photoacoustic Imaging
Zackrisson, S., van de Ven, S. M. W. Y., & Gambhir, S. S. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2387 · Cited by 480
Qiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S. (2015) · Sensors · doi:10.3390/s150408020 · Cited by 395
Ultrasensitive plano-concave optical microresonators for ultrasound sensing
Guggenheim, J. A., Li, J., Allen, T. J., Colchester, R. J., Noimark, S., Ogunlade, O., Parkin, I. P., Papakonstantinou, I., Desjardins, A. E., Zhang, E. Z., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0027-x · Cited by 391
Wang, Z., Chan, H. L. W., Li, H., & Hao, J. (2008) · Applied Physics Letters · Cited by 383
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, B. T., & Oralkan, Ö. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054004 · Cited by 332
Bucaro, J. A., Dardy, H. D., & Carome, E. F. (1977) · The Journal of the Acoustical Society of America · doi:10.1121/1.381624 · Cited by 331
In vivo preclinical photoacoustic imaging of tumor vasculature development and therapy
Laufer, J. G., Zhang, E. Z., Treeby, B. E., Cox, B. T., Beard, P. C., Johnson, P., & Pedley, B. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056016 · Cited by 308
Morris, P., Hurrell, A., Shaw, A., Zhang, E., & Beard, P. (2009) · The Journal of the Acoustical Society of America · doi:10.1121/1.3117437 · Cited by 285
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
Wygant, I. O., Zhuang, X., Yeh, D. T., Oralkan, O., Ergun, A. S., Karaman, M., & Khuri-Yakub, B. T. (2008) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.652 · Cited by 248
Li, H., Dong, B., Zhang, Z., Zhang, H. F., & Sun, C. (2014) · Scientific Reports · doi:10.1038/srep04496 · Cited by 224
Zhang, E. Z., Povazay, B., Laufer, J., Alex, A., Hofer, B., Pedley, B., Glittenberg, C., Treeby, B., Cox, B., Beard, P., et al. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002202 · Cited by 190
Optical Detection of Ultrasound in Photoacoustic Imaging
Dong, B., Sun, C., & Zhang, H. F. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2605451 · Cited by 170
Noise-equivalent sensitivity of photoacoustics
Winkler, A. M., Maslov, K., & Wang, L. V. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.9.097003 · Cited by 142
Laufer, J. G., Zhang, E., Raivich, G., & Beard, P. C. (2009) · Applied Optics · doi:10.1364/ao.48.00d299 · Cited by 141
Through-needle all-optical ultrasound imaging in vivo: a preclinical swine study
Finlay, M., Mosse, C. A., Colchester, R. J., Noimark, S., Zhang, E., Sebastien Ourselin, A., Beard, P. C., SCHILLING, R. J., Parkin, I. P., Papakonstantinou, I., et al. (2017) · Light Science & Applications · doi:10.1038/lsa.2017.103 · Cited by 127
Omar, M., Schwarz, M., Soliman, D., Symvoulidis, P., & Ntziachristos, V. (2015) · Neoplasia · doi:10.1016/j.neo.2014.12.010 · Cited by 119
Self-citationPure optical photoacoustic microscopy
Xie, Z., Chen, S., Ling, T., Guo, L. J., Carson, P. L., & Wang, X. (2011) · Optics Express · doi:10.1364/oe.19.009027 · Cited by 112
Dong, B., Li, H., Zhang, Z., Zhang, K. X., Chen, S., Sun, C., & Zhang, H. F. (2015) · Optica · doi:10.1364/optica.2.000169 · Cited by 110
Photoacoustic probe using a microring resonator ultrasonic sensor for endoscopic applications
Dong, B., Chen, S., Zhang, Z., Sun, C., & Zhang, H. F. (2014) · Optics Letters · doi:10.1364/ol.39.004372 · Cited by 107
Vibrational Displacement and Mode-Shape Measurement by a Laser Interferometer
DeFerrari, H. A., Darby, R. A., & Andrews, F. A. (1967) · The Journal of the Acoustical Society of America · doi:10.1121/1.1910707 · Cited by 101
High resolution ultrasound and photoacoustic imaging of single cells
Strohm, E. M., Moore, M. J., & Kolios, M. C. (2016) · Photoacoustics · doi:10.1016/j.pacs.2016.01.001 · Cited by 101
Rosenthal, A., Kellnberger, S., Bozhko, D., Chekkoury, A., Omar, M., Razansky, D., & Ntziachristos, V. (2014) · Laser & Photonics Review · doi:10.1002/lpor.201300204 · Cited by 96
Self-citationNon-contact photoacoustic imaging using a fiber based interferometer with optical amplification
Hochreiner, A., Bauer-Marschallinger, J., Burgholzer, P., Jakoby, B., & Berer, T. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.002322 · Cited by 86
Nie, L., Ou, Z., Yang, S., & Xing, D. (2010) · Medical Physics · doi:10.1118/1.3466696 · Cited by 86
A magneto-acoustic method for the noninvasive measurement of bioelectric currents
Towe, B. C., & Islam, M. R. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7300 · Cited by 85
Laser-Ultrasonics: From the Laboratory to Industry
Monchalin, J. (2004) · AIP conference proceedings · doi:10.1063/1.1711602 · Cited by 81
All-optical broadband ultrasonography of single cells
Dehoux, T., Ghanem, M. A., Zouani, O. F., Rampnoux, J., Guillet, Y., Dilhaire, S., Durrieu, M., & Audoin, B. (2015) · Scientific Reports · doi:10.1038/srep08650 · Cited by 76
Nuster, R., Slezak, P., & Paltauf, G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002635 · Cited by 70
Zabihian, B., Weingast, J., Liu, M., Zhang, E., Beard, P. C., Pehamberger, H., Drexler, W., & Hermann, B. M. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003163 · Cited by 66
Ultrasonic detection based on polarization-dependent optical reflection
Zhu, X., Huang, Z., Wang, G., Li, W., Zou, D., & Li, C. (2017) · Optics Letters · doi:10.1364/ol.42.000439 · Cited by 65
High frequency ultrasound imaging with optical arrays
Hamilton, J. D., & O’Donnell, M. P. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.646927 · Cited by 62
All-optical photoacoustic microscopy based on plasmonic detection of broadband ultrasound
Wang, T., Cao, R., Ning, B., Dixon, A. J., Hossack, J. A., Klibanov, A. L., Zhou, Q., Wang, A., & Hu, S. (2015) · Applied Physics Letters · doi:10.1063/1.4933333 · Cited by 62
All-optical optoacoustic microscope based on wideband pulse interferometry
Wissmeyer, G., Soliman, D., Shnaiderman, R., Rosenthal, A., & Ntziachristos, V. (2016) · Optics Letters · doi:10.1364/ol.41.001953 · Cited by 61
Self-citationNDT of fiber-reinforced composites with a new fiber-optic pump–probe laser-ultrasound system
Pelivanov, I., Buma, T., Xia, J., Wei, C., & O’Donnell, M. (2014) · Photoacoustics · doi:10.1016/j.pacs.2014.01.001 · Cited by 57
An optimized ultrasound detector for photoacoustic breast tomography
Xia, W., Piras, D., van Hespen, J. C. G., van Veldhoven, S., Prins, C., van Leeuwen, T. G. J. M., Steenbergen, W., & Manohar, S. (2013) · Medical Physics · doi:10.1118/1.4792462 · Cited by 56
All-optical optoacoustic microscopy based on probe beam deflection technique
Maswadi, S. M., Ibey, B. L., Roth, C. C., Tsyboulski, D. A., Beier, H. T., Glickman, R. D., & Oraevsky, A. A. (2016) · Photoacoustics · doi:10.1016/j.pacs.2016.02.001 · Cited by 56
Embedded ultrasound sensor in a silicon-on-insulator photonic platform
Rosenthal, A., Omar, M., Estrada, H., Kellnberger, S., Razansky, D., & Ntziachristos, V. (2014) · Applied Physics Letters · doi:10.1063/1.4860983 · Cited by 55
Self-citationLetters: optically transparent piezoelectric transducer for ultrasonic particle manipulation
Brodie, G., Qiu, Y., Cochran, S., Spalding, G. C., & MacDonald, M. P. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2923 · Cited by 53
Photoacoustic microtomography using optical interferometric detection
Nuster, R., Holotta, M., Kremser, C., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3333547 · Cited by 49
Magnetoacoustic Sensing of Magnetic Nanoparticles
Kellnberger, S., Rosenthal, A., Myklatun, A., Westmeyer, G. G., Sergiadis, G. D., & Ntziachristos, V. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.108103 · Cited by 35
Self-citationPiao, D. D., Towner, R. A., Smith, N., & Chen, W. R. (2013) · Medical Physics · doi:10.1118/1.4804056 · Cited by 29
Optical methods for visualization of ultrasound fields
Kudo, N. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.07ha01 · Cited by 24
Intravascular multispectral optoacoustic tomography of atherosclerosis: prospects and challenges
Rosenthal, A., Jaffer, F. A., & Ntziachristos, V. (2012) · Imaging in Medicine · doi:10.2217/iim.12.20 · Cited by 24
Self-citationMultiplexing of fiber-optic ultrasound sensors via swept frequency interferometry
Gabai, H., Steinberg, I., & Eyal, A. (2015) · Optics Express · doi:10.1364/oe.23.018915 · Cited by 20
Cited by
Sensitive, small, broadband and scalable optomechanical ultrasound sensor in silicon photonics
Westerveld, W. J., Mahmud-Ul-Hasan, M., Shnaiderman, R., Ntziachristos, V., Rottenberg, X., Severi, S., & Rochus, V. (2021) · Nature Photonics · doi:10.1038/s41566-021-00776-0 · Cited by 257
Self-citationA submicrometre silicon-on-insulator resonator for ultrasound detection
Shnaiderman, R., Wissmeyer, G., Ülgen, O., Mustafa, Q., Chmyrov, A., & Ntziachristos, V. (2020) · Nature · doi:10.1038/s41586-020-2685-y · Cited by 178
Self-citation
Metadata
- Authors
- Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V.
- Venue
- Light: Science & Applications
- Published
- 2018-08-15
- Volume
- 7
- Issue
- 1
- Pages
- 53-53
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2885304391
- Cited by
- 374
- References
- 52
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.