The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging
Open accessAbstract
Many applications of ultrasound for sensing, actuation and imaging require miniaturized and low power transducers and transducer arrays integrated with electronic systems. Piezoelectric micromachined ultrasound transducers (PMUTs), diaphragm-like thin film flexural transducers typically formed on silicon substrates, are a potential solution for integrated transducer arrays. This paper presents an overview of the current development status of PMUTs and a discussion of their suitability for miniaturized and integrated devices. The thin film piezoelectric materials required to functionalize these devices are discussed, followed by the microfabrication techniques used to create PMUT elements and the constraints the fabrication imposes on device design. Approaches for electrical interconnection and integration with on-chip electronics are discussed. Electrical and acoustic measurements from fabricated PMUT arrays with up to 320 diaphragm elements are presented. The PMUTs are shown to be broadband devices with an operating frequency which is tunable by tailoring the lateral dimensions of the flexural membrane or the thicknesses of the constituent layers. Finally, the outlook for future development of PMUT technology and the potential applications made feasible by integrated PMUT devices are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
Ultrasonic arrays for non-destructive evaluation: A review
Drinkwater, B. W., & Wilcox, P. D. (2006) · NDT & E International · doi:10.1016/j.ndteint.2006.03.006 · Cited by 1,147
Thin Film Piezoelectrics for MEMS
Trolier-McKinstry, S., & Muralt, P. (2004) · Journal of Electroceramics · doi:10.1023/b:jecr.0000033998.72845.51 · Cited by 1,023
Self-citationSurface micromachined capacitive ultrasonic transducers
Ladabaum, I., Jin, X., Soh, H. T., Atalar, A., & Khuri-Yakub, B. T. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.677612 · Cited by 581
INVESTIGATION OF ABDOMINAL MASSES BY PULSED ULTRASOUND
Donald, I., Macvicar, J., & Brown, T. G. (1958) · The Lancet · doi:10.1016/s0140-6736(58)91905-6 · Cited by 568
High-Temperature Piezoelectric Sensing
Jiang, X., Kim, K., Zhang, S., Johnson, J., & Salazar, G. (2013) · Sensors · doi:10.3390/s140100144 · Cited by 435
3-D ultrasound imaging: a review
Fenster, A., & Downey, D. B. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544511 · Cited by 403
Piezoelectric films for high frequency ultrasonic transducers in biomedical applications
Zhou, Q., Lau, S., Wu, D., & Kirk Shung, K. (2011) · Progress in Materials Science · doi:10.1016/j.pmatsci.2010.09.001 · Cited by 377
PZT thin films for microsensors and actuators: Where do we stand?
Muralt, P. (2000) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.852073 · Cited by 375
Piezoelectric micromachined ultrasonic transducers based on PZT thin films
Muralt, P., Ledermann, N., Paborowski, J., Barzegar, A., Gentil, S., Belgacem, B., Petitgrand, S., Bosseboeuf, A., & Setter, N. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1563270 · Cited by 332
Cited by
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Birjis, Y., Swaminathan, S., Nazemi, H., Raj, G. C. A., Munirathinam, P., Abu-Libdeh, A., & Emadi, A. (2022) · Sensors · doi:10.3390/s22239151 · Cited by 84
Metadata
- Authors
- Qiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-04-03
- Volume
- 15
- Issue
- 4
- Pages
- 8020-8041
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2012779095
- Cited by
- 395
- References
- 38
- FWCI
- 19.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging. https://app.cochat.ai/papers/10.3390/s150408020
- The paper
- Qiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S. (2015). Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging. Sensors. https://doi.org/10.3390/s150408020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.