Stretchable and durable HD-sEMG electrodes for accurate recognition of swallowing activities on complex epidermal surfaces
Open accessPublished version of a preprint
The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Abstract
Surface electromyography (sEMG) is widely used in monitoring human health. Nonetheless, it is challenging to capture high-fidelity sEMG recordings in regions with intricate curved surfaces such as the larynx, because regular sEMG electrodes have stiff structures. In this study, we developed a stretchable, high-density sEMG electrode array via layer-by-layer printing and lamination. The electrode offered a series of excellent human‒machine interface features, including conformal adhesion to the skin, high electron-to-ion conductivity (and thus lower contact impedance), prolonged environmental adaptability to resist water evaporation, and epidermal biocompatibility. This made the electrode more appropriate than commercial electrodes for long-term wearable, high-fidelity sEMG recording devices at complicated skin interfaces. Systematic in vivo studies were used to investigate its ability to classify swallowing activities, which was accomplished with high accuracy by decoding the sEMG signals from the chin via integration with an ear-mounted wearable system and machine learning algorithms. The results demonstrated the clinical feasibility of the system for noninvasive and comfortable recognition of swallowing motions for comfortable dysphagia rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“in the use of electromyography, AI aims to improve signal capture and analysis quality(3,17).”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [17]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Han, L., Liu, K., Wang, M., Wang, K., Fang, L., Chen, H., Zhou, J., & Lu, X. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201704195 · Cited by 1,160
3D printing of conducting polymers
Yuk, H., Lu, B., Lin, S., Qu, K., Xu, J., Luo, J., & Zhao, X. (2020) · Nature Communications · doi:10.1038/s41467-020-15316-7 · Cited by 1,001 · cited 1×
“It can be enhanced by adding ions or by adding conductive fi llers such as carbon nanotubes and conductive polymers 28 – 31 .”
BackgroundClassification of Skin Disease Using Deep Learning Neural Networks with MobileNet V2 and LSTM
Srinivasu, P. N., SivaSai, J. G., Ijaz, M. F., Bhoi, A. K., Kim, W., & Kang, J. J. (2021) · Sensors · doi:10.3390/s21082852 · Cited by 759
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661 · cited 1×
“Given that it has the lowest hardness of 10 kPa, which was similar to that of human soft tissue 37 , and the highest stretchability of 960%, the GW-PA gel with 50% (w/w) glycerol was chosen for construction of the GW-PA-Ag electrode.”
MethodAn electrically conductive silver–polyacrylamide–alginate hydrogel composite for soft electronics
Ohm, Y., Pan, C., Ford, M. J., Huang, X., Liao, J., & Majidi, C. (2021) · Nature Electronics · doi:10.1038/s41928-021-00545-5 · Cited by 546 · cited 1×
“The other category uses conductive fi llers fi lled with intrinsically stretchable composites, such as hydrogels or Poly-dimethylsiloxane (PDMS) fi lled with silver nanosh-eets 11,20 – 23 .”
Material‐Based Approaches for the Fabrication of Stretchable Electronics
Kim, D. C., Shim, H. J., Lee, W., Koo, J. H., & Kim, D. (2020) · Advanced Materials · doi:10.1002/adma.201902743 · Cited by 438
Solution-processable, soft, self-adhesive, and conductive polymer composites for soft electronics
Tan, P., Wang, H., Xiao, F., Lu, X., Shang, W., Deng, X., Song, H., Xu, Z., Cao, J., Gan, T., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28027-y · Cited by 403 · cited 1×
“In addition, commercial electrodes add a gel serving as a binder and ionic medium, which leads to loss of signal quality due to dehydration over long periods of use 5,6 .”
BackgroundWu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395 · cited 1×
“This model enables real-time monitoring of the patient ’ s health status, and the data are processed and saved via wireless transmission, and the results are presented with simple visualizations 3,4 .”
Method
Cited by
Lee, H. K., Yang, Y. J., Koirala, G. R., Oh, S., & Kim, T. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122632 · Cited by 56
Zhou, Z., Jin, Y., Fu, J., Si, S., Liu, M., Hu, Y., Gan, J., Deng, Y., Li, R., & Yang, J. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00388-6 · Cited by 56
“With the aging population and the increasing prevalence of sedentary lifestyles, there has been a surge in demand for physiological monitoring devices, particularly for the continuous tracking of vital signs such as heart rate and respiration 1 – 14 .”
Soft skin-interfacing electrodes for wearable bioelectronics
Carneiro, M. R., Tavakoli, M., & Majidi, C. (2025) · Matter · doi:10.1016/j.matt.2025.102409 · Cited by 44
Li, R., Xiang, H., Liang, Q., Zhou, Y., Ma, X., Chao, D., Xin, M., Yuan, H., & Jia, X. (2024) · Nano Energy · doi:10.1016/j.nanoen.2024.109946 · Cited by 27
Zhong, G., Liu, Q., Huang, Y., Geng, H., & Xu, T. (2025) · Advanced Materials · doi:10.1002/adma.202508206 · Cited by 27
Song, Y., Yun, I., Giovanoli, S., Easthope, C. A., & Chung, Y. (2025) · npj Digital Medicine · doi:10.1038/s41746-024-01417-w · Cited by 27
“For example, piezoresistive and surface electromyography (sEMG) sensors were utilized to detect swallowing events 14,15 .”
3D printable and myoelectrically sensitive hydrogel for smart prosthetic hand control
Lai, J., Xiao, L., Zhu, B., Xie, L., & Jiang, H. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00825-y · Cited by 23
Self-citationAdvancements and Challenges in Non-Invasive Sensor Technologies for Swallowing Assessment: A Review
Wu, Y., Guo, K., Chu, Y., Wang, Z., Yang, H., & Zhang, J. (2024) · Bioengineering · doi:10.3390/bioengineering11050430 · Cited by 20
“Therefore, in needle electrode monitoring, several electrodes are usually inserted at the same time, and the insertion location and depth need to be carefully selected to ensure reliable data acquisition.”
BackgroundAdhesive hydrogel interface for enhanced epidermal signal
Shi, X., Yu, H. C., Tang, Z., Lu, S., You, M., Yin, H., & Chen, Q. (2024) · Science China Technological Sciences · doi:10.1007/s11431-024-2638-x · Cited by 18
“For example, Tian et al. [92] developed a wearable wireless electromyography signal acquisition system to classify swallowing movements.”
Yang, J., Shibata, K., Weber, D. J., & Erickson, Z. (2025) · npj Robotics · doi:10.1038/s44182-025-00018-3 · Cited by 35
“One recent work by Zhang et al. 66 developed a fl exible PCB with semi-permanent hydrogel electrodes for a neck-worn interface using a custom layer-by-layer fabrication approach.”
Xu, S., Kantarcigil, Ç., Rangwala, R., Nellis, A. B., Chun, K. S., Richards, D., Albert-Smet, I., Keller, M., Chen, H., Huang, J., et al. (2025) · Journal of Parkinson s Disease · doi:10.1177/1877718x251329354 · Cited by 15
“3,4 Up to 80% of patients with PD exhibit dysphagia, 5 which can lead to dehydration, malnutrition, and dif fi culty with oral medication intake, and aspiration pneumonia, a leading cause of death in patients with PD. 6,7 Impairment in the physiological coordination of breathing and swallowing in patients with PD furth…”
InfluentialMRI and CT compatible asymmetric bilayer hydrogel electrodes for EEG-based brain activity monitoring
Ren, G., Zhang, M., Zhuang, L., Li, L., Zhao, S., Guo, J., Zhao, Y., Peng, Z., Lian, J., Liu, B., et al. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00805-2 · Cited by 16
Using biopotential and bio-impedance for intuitive human–robot interaction
Park, K., Jeong, H., Jung, Y., Suh, J.-H., Je, M., & Kim, J. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00191-5 · Cited by 13
Hong, W., Mao, L., Lin, K., Huang, C., Su, Y., Zhang, S., Wang, C., Wang, D., Song, J., & Chen, Z. (2025) · Advanced Science · doi:10.1002/advs.202500472 · Cited by 11
Self-citationHu, X., Wang, C., Huang, J., Yan, Y., Liao, X., Li, Y., & Li, L. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401800 · Cited by 8
Rescio, G., Sciurti, E., Giampetruzzi, L., Carluccio, A. M., Francioso, L. N., & Leone, A. (2025) · Sensors · doi:10.3390/s25051618 · Cited by 10
“These hydrogels are typically fabricated with biocompatible polymers and are more skin-friendly than traditional metal electrodes, reducing the risk of irritation and allergic reactions during prolonged use [22].”
Wearable, Wireless, Stretchable, High‐Density Surface Electromyography Interface
Zhao, Y., Zhang, N., Li, J., Ren, J., & Gu, G. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500607 · Cited by 8
Recent advances in wearable biophysical sensors for continuous muscle monitoring
Zheng, R., & Xu, H. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118463 · Cited by 8
Zhang, D., Chen, Z., Xiao, L., Zhu, B., Wu, R., Ou, C., Ma, Y., Xie, L., & Jiang, H. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00621-0 · Cited by 7
Self-citationArtificial intelligence in the diagnosis and management of dysphagia: a scoping review
Silva, R. D. D., Almeida, S. B., Gonçalves, F. M., Zeigelboim, B. S., Stechman-Neto, J., Schroder, A. G. D., Nascimento, W. V., Santos, R. S., & Araujo, C. M. D. (2025) · CoDAS · doi:10.1590/2317-1782/e20240305en · Cited by 6
“Videofluoroscopy swallowing study (VFSS) was utilized in studies (16,23-28) , with four of them concurrently using high-resolution manometry (27,29-31) , only two studies (32,33) used fiberoptic endoscopic evaluation of swallowing (FEES), and 2 studies reported electromyography use (3,17) .”
A dual-signal hydrogel sensor advances prosthesis manipulation towards precision motion control
Shi, X., Zhang, Z., Liu, X., Zhang, R., Pei, Y., Ding, S., Zhou, X., Song, X., Tang, Z., Sun, G., et al. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.169648 · Cited by 8
Ou, C., Jiang, H., Xiao, L., Zhang, D., Ma, Y., Feng, S., & Wu, K. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114846 · Cited by 6
Self-citationWang, S., Jin, J., Liu, W., Xu, Z., Mei, D., & Wang, Y. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00397-5 · Cited by 5
“This is because it usually makes electronics conformal by physically cutting them into stretchable structures 31 – 34 .”
Surface EMG in China: a report on the 2023 surface EMG symposium
Zhou, P. (2024) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2024.1353564 · Cited by 3
Kainz, M. P., Polz, M., Ziesel, D., Nowakowska, M., Üçal, M., Kienesberger, S., Hasiba-Pappas, S. K., Winter, R., Ghaffari‐Tabrizi‐Wizsy, N., Kager, S., et al. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.101508 · Cited by 4
Dong, P., Ives, J., Garcia, E., Caporusso, C., Bragina, P., Laguatan, C., & Yao, S. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500229 · Cited by 3
ReGrid: A Highly Conformable and Ultrasound Transparent Patch for HD-sEMG Detection
Cerone, G. L., Vieira, T., Gazzoni, M., & Botter, A. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3663330 · Cited by 2
“Results are reported as median ± standard deviation.”
Yang, R., Hou, Y., Blade, S., Li, Y., Tyagi, V., Boudreault-Morales, G.-E., Zariffa, J., & Liu, X. (2024) · Integrated Circuits and Systems · doi:10.23919/ics.2024.3512503 · Cited by 3
Functional Hydrogels for Wearable Electronics
Zameer, A., Qin, Y., Xu, H., Liang, Q., & Zhang, Q. M. (2025) · Macromolecular Chemistry and Physics · doi:10.1002/macp.202400491 · Cited by 3
Repaint High-Density Surface Electromyography Signal Using Denoising Diffusion Probabilistic Model
Zhao, Y., Liao, J., Fang, X., Wang, H. R., Jiang, N., & He, J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3604527 · Cited by 1
Remote energy transfer strategies for flexible implantable bioelectronics
Imani, I. M., Kim, E., Kim, T., Min, B.-J., Song, H., Hwang, J., Kim, S., Kim, Y., Park, B. C., Lee, J. H., et al. (2026) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2026.101260 · Cited by 2
MRI and CT Compatible Asymmetric Bilayer Hydrogel Electrodes for EEG-Based Brain Activity MonitoringPreprint
Lu, Q., Ren, G., Zhang, M., Zhuang, L., Li, L., Zhao, S., Guo, J., Zhao, Y., Peng, Z., Lian, J., et al. (2024) · Research Square · doi:10.21203/rs.3.rs-4657809/v1 · Cited by 1
Ng, J. C., Philimon, S. P., & Huong, A. K. C. (2025) · International Conference on Electrical, Electronics and System Engineering (ICEESE) · doi:10.1109/iceese66784.2025.11212747
“In addition, more advanced electrodes and sensors would produce a better skin interface, maintain optimal contact, and eliminate motion artifacts [15-16].”
Wang, Z., Chen, Z., Li, J., Jia, D., Hou, X., Li, Z., & Fan, H. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01247-8
“…(EEG) 5 , and electromyograms (EMG) 6 – 8 , the integration of electronic devices with irregular, fl exible surfaces has become increasingly crucial for a variety of emerging applications, including wearable electronics 9 – 11 , soft robotics 12,13 , and human – machine interfaces 14,15 .”
Self-citationResearch Progress of La1-xSrxMnO3-Based Flexible Wearable Sensors
Xing, X., Fan, X., Li, R., Lu, B., Ma, Y., Jia, C., Gao, D., Wu, J., 国岡, 稔., & Zhong, M. (2026) · Micromachines · doi:10.3390/mi17050629 · Cited by 1
Self-citationSoft Active Electromyography Interface for Machine Learning‐Enabled Silent Speech Recognition
Kurotaki, Y., Yamakoshi, S., Yoshida, R., Isoda, Y., Takano, T., Isano, Y., Miyake, Y., Kuribayashi, K., & Ota, H. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.70440 · Cited by 2
“Electrodes based on PEDOT:PSS 13,28 , carbon nanotubes or carbon black 29,30,31 , and silver paste 32 have been reported.”
Boccali, E., Amitrano, F., Coccia, A., Olivares, A., Comini, L., D’Addio, G., & Pietro, D. A. D. (2026) · Applied Sciences · doi:10.3390/app16126075
Sung, J., Roh, H., & Kang, H. (2026) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps69128.2026.11645074
“When implemented on stretchable and skin-conformal substrates, such arrays further support stable signal acquisition under natural arm movements and extended wear conditions, facilitating wearable applications [6-7].”
Hu, Q., Xiao, L., & Jiang, H. (2026) · Chem & Bio Engineering · doi:10.1021/cbe.6c00128
Self-citationModulus-matched epidermal biointerfaces for robust surface electromyography sensing
Luo, G., Tan, J., Luo, W., Xie, J., Li, W., Li, Z., Li, M., Yang, P., Maeda, R., Zhao, P., et al. (2026) · Bio-Design and Manufacturing · doi:10.1631/bdm.2500553
Jeong, J., & Jung, D. (2026) · Gels · doi:10.3390/gels12100883
Silk Fibroin-Based Flexible Electronics: A Mesoscopic Pathway Toward Human–Machine Interconnection
Li, J., Gao, S., Wang, C., Xiahou, J., & Liu, X. (2026) · Advanced Fiber Materials · doi:10.1007/s42765-026-00777-0
Metadata
- Authors
- Zhang, D., Chen, Z., Xiao, L., Zhu, B., Wu, R., Ou, C., Ma, Y., Xie, L., & Jiang, H.
- Affiliations
- South China University of Technology (CN)
- Corresponding author
- Xie, Longhan
- Jiang, Hongjie
- Venue
- Microsystems & Nanoengineering
- Published
- 2023-09-18
- Volume
- 9
- Issue
- 1
- Pages
- 115-115
- ISSN
- 2055-7434 (ISSN-L)
- PMC
- PMC10507084
- OpenAlex
- W4386835103
- Cited by
- 43
- References
- 46
- Citations by year
- 2026: 13 · 2025: 20 · 2024: 8 · 2023: 2
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Update notices
- correction (2023-11-24)
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Microsystems & Nanoengineering (publishedVersion, cc-by)
- Research Square (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (No. 52075177, 52075177, 42177440, Grant No. 52075177, 51903079)
- National Key Research and Development Program of China (No. 2021YFB3301400, 52075177, 2021YFB3301400)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- high-density electrode arrays, swallowing rehabilitation, laryngeal electromyography, layer-by-layer printing, lamination, contact impedance, wearable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.