Research progress of electronic nose technology in exhaled breath disease analysis
Open accessThe DOI matches its Crossref record; 153 of the 153 references it cites were found in a registry or an index.
Abstract
Exhaled breath analysis has attracted considerable attention as a noninvasive and portable health diagnosis method due to numerous advantages, such as convenience, safety, simplicity, and avoidance of discomfort. Based on many studies, exhaled breath analysis is a promising medical detection technology capable of diagnosing different diseases by analyzing the concentration, type and other characteristics of specific gases. In the existing gas analysis technology, the electronic nose (eNose) analysis method has great advantages of high sensitivity, rapid response, real-time monitoring, ease of use and portability. Herein, this review is intended to provide an overview of the application of human exhaled breath components in disease diagnosis, existing breath testing technologies and the development and research status of electronic nose technology. In the electronic nose technology section, the three aspects of sensors, algorithms and existing systems are summarized in detail. Moreover, the related challenges and limitations involved in the abovementioned technologies are also discussed. Finally, the conclusion and perspective of eNose technology are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal Oxide Gas Sensors: Sensitivity and Influencing Factors
Wang, C., Yin, L., Zhang, L., Xiang, D., & Gao, R. (2010) · Sensors · doi:10.3390/s100302088 · Cited by 2,928 · cited 1×
“The sensitivity can be de fi ned as R a /R g (for reducing gases) or R g /R a (for oxidizing gases), where R a represents the resistance of the gas sensor in the reference gas (generally air) and R g represents the resistance of the gas sensor in the reference gas containing the target gas 86 .”
BackgroundPorous materials with optimal adsorption thermodynamics and kinetics for CO2 separation
Nugent, P., Belmabkhout, Y., Burd, S. D., Cairns, A. J., Luebke, R., Forrest, K., Pham, T., Ma, S., Space, B., Wojtas, L., et al. (2013) · Nature · doi:10.1038/nature11893 · Cited by 2,387 · cited 1×
“Nanostructured materials, such as nanowires, nanosh-eets, nanospheres, and nanopetals, have been used for VOC detection 87 – 90 , 91 , and composite metal oxides, such as La 2 O 3 -SnO 2 , In-WO 3 - SnO 2 , and ZnO-SnO 297 – 99 .”
MethodHodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745 · cited 1×
“However, the optical sensor equipment system is complex and costly to operate 125 .”
BackgroundGas Sensors Based on Conducting Polymers
Bai, H., & Shi, G. (2007) · Sensors · doi:10.3390/s7030267 · Cited by 1,577
Polymers in sensor applications
Adhikari, B., & Majumdar, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.03.002 · Cited by 1,181
Applications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144 · cited 4×
“…discriminant analysis (LDA) 6,19,82,130,131 , support vector machine (SVM) 2,6,19,70,130,132,133 , decision tree (DT) 2,130 , K-nearest neighbor (KNN) 2,6,19,130,134 , cluster analysis (CA) 115 , canonical discriminant analysis (CDA) 115 , partial least squares regression (PLS) 63 , and others.”
BackgroundMethodInfluentialDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096 · cited 3×
“Many studies have shown that acetone is one of the most abundant VOCs in human respiration 4,47 – 49 .”
BackgroundQuantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025 · cited 1×
“In 1971, Linus et al. published a signi fi cant article in which more than 200 ppm levels of VOCs were detected in exhaled gas through gas chromatography 26 .”
MethodThe scent of disease: volatile organic compounds of the human body related to disease and disorder
Shirasu, M., & Touhara, K. (2011) · Journal of Biochemistry · doi:10.1093/jb/mvr090 · Cited by 619
Advanced Micro- and Nano-Gas Sensor Technology: A Review
Nazemi, H., Joseph, A., Park, J., & Emadi, A. (2019) · Sensors · doi:10.3390/s19061285 · Cited by 614 · cited 1×
“…arrays in the eNose system are typically analyzed using classical machine learning algorithms, such as principal component analysis (PCA) 6,82,115,129,130 , linear discriminant analysis (LDA) 6,19,82,130,131 , support vector machine (SVM) 2,6,19,70,130,132,133 , decision tree (DT) 2,130 ,…”
MethodDetection of Lung Cancer by Sensor Array Analyses of Exhaled Breath
Machado, R. F., Laskowski, D., Deffenderfer, O., Burch, T., Zheng, S., Mazzone, P. J., Mekhail, T., Jennings, C., Stoller, J. K., Pyle, J., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1184oc · Cited by 602 · cited 2×
“The application of eNose in clinical medicine mainly includes early screening of various cancers 21 , lung diseases, such as pneumonia and upper respiratory tract infection 22 , diabetes 23 , identi fi cation of bacterial pathogens 24 , and microbial metabolites released from super fi cial wounds 25 .”
MethodYou, H., Mu, Z., Zhao, M., Zhou, J., Chen, Y., & Bai, L. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3127-5 · Cited by 592
Conductive polymer-based sensors for biomedical applications
Nambiar, S., & Yeow, J. T. W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.046 · Cited by 513 · cited 1×
“The material properties of CP are similar to those of some metal and inorganic semiconductor materials, while retaining the fl exibility of the polymer and having the advantage of easy processing and synthesis 101 .”
MethodBreath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487 · cited 1×
“Nanostructured materials, such as nanowires, nanosh-eets, nanospheres, and nanopetals, have been used for VOC detection 87 – 90 , 91 , and composite metal oxides, such as La 2 O 3 -SnO 2 , In-WO 3 - SnO 2 , and ZnO-SnO 297 – 99 .”
MethodReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412 · cited 1×
“The concentration of acetone in the exhaled breath of diabetic patients can reach 2 – 6 times higher than that of the H subjects, as shown in Table 1 51 – 53 .”
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410 · cited 3×
“These compounds contain trace amounts of volatile organic compounds (VOCs) and some nonvolatile components, usually between one trillionth (ppt) and one millionth (ppm) 7 .”
BackgroundMethodAn electronic nose in the discrimination of patients with non-small cell lung cancer and COPD
Dragonieri, S., Annema, J. T., Schot, R., van der Schee, M. P. C., Spanevello, A., Carratú, P., Resta, O., Rabe, K. F., & Sterk, P. J. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2008.08.008 · Cited by 407
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400 · cited 1×
“The development of eNose technology in the fi eld of health care has greatly expanded 20 .”
BackgroundBreath Analysis: Potential for Clinical Diagnosis and Exposure Assessment
Cao, W., & Duan, Y. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063545 · Cited by 391 · cited 1×
“When one or more gas concentration exceed a certain range or some speci fi c gases are produced, they often cause changes in the body ’ s disease or metabolic function 9 – 11 .”
BackgroundMultiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c05657 · Cited by 384
Self-citationGisbert, J. P., & Pajares, J. M. (2004) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2004.02203.x · Cited by 374
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Electronic Nose and Its Applications: A Survey
Karakaya, D., Ulucan, O., & Turkan, M. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-019-1212-9 · Cited by 353 · cited 4×
“To enable precise detection of breath-related diseases with complex components, integration of multiple speci fi c sensors into a sensing array is needed to achieve high-precision detection 81 .”
BackgroundMethodInfluentialElectronic Nose Feature Extraction Methods: A Review
Yan, J., Guo, X., Duan, S., Jia, P., Wang, L., Peng, C., & Zhang, S. (2015) · Sensors · doi:10.3390/s151127804 · Cited by 338 · cited 1×
“Notably, it has been applied in clinical medicine, including early screening of diverse cancers 75 , lung diseases 76 , diabetes 77 , bacterial pathogen identi fi cation 78,79 , and in the analysis of microbial metabolites from super fi cial wounds 25,80 .”
MethodVolatile Organic Compounds in Exhaled Breath as Fingerprints of Lung Cancer, Asthma and COPD
Ratiu, I. A., Ligor, T., Bocos-Bintintan, V., Mayhew, C. A., & Buszewski, B. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm10010032 · Cited by 320
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317 · cited 1×
“The concentration of acetone in the exhaled breath of diabetic patients can reach 2 – 6 times higher than that of the H subjects, as shown in Table 1 51 – 53 .”
Heme Oxygenase-1/Carbon Monoxide: From Metabolism to Molecular Therapy
Ryter, S. W., & Choi, A. M. K. (2009) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2009-0170tr · Cited by 308
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287 · cited 4×
“Additionally, gas sensor analysis grounded in electrochemical principles constitutes a signi fi cant methodological ave-nue 18,66 .”
BackgroundMethodInfluentialGC–MS analysis of breath odor compounds in liver patients
VANDENVELDE, S., NEVENS, F., VANHEE, P., VANSTEENBERGHE, D., & QUIRYNEN, M. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.08.031 · Cited by 274 · cited 6×
“Currently, gas detection meth-ods utilizing GC primarily include thermal desorption-gas chromatography (TD-GC) 68 , gas chromatography-hydrogen fl ame ionization detector (GC-FID) 50 , gas chromatography-ion mobility spectrometry (GC-IMS) 69 and gas chromatography-mass spectrometry (GC-MS) 62 .”
BackgroundMethodInfluentialAn acetone gas sensor based on nanosized Pt-loaded Fe2O3 nanocubes
Zhang, S., Yang, M., Liang, K., Turak, A., Zhang, B., Meng, D., Wang, C., Qu, F., Cheng, W., & Yang, M. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.03.082 · Cited by 265 · cited 1×
“5c) 93 .”
Güntner, A. T., Koren, V., Chikkadi, K., Righettoni, M., & Pratsinis, S. E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00008 · Cited by 257
Saidi, T., Zaim, O., Moufid, M., El Bari, N., Ionescu, R., & Bouchikhi, B. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.10.178 · Cited by 255 · cited 7×
“Currently, gas detection meth-ods utilizing GC primarily include thermal desorption-gas chromatography (TD-GC) 68 , gas chromatography-hydrogen fl ame ionization detector (GC-FID) 50 , gas chromatography-ion mobility spectrometry (GC-IMS) 69 and gas chromatography-mass spectrometry (GC-MS) 62 .”
BackgroundMethodInfluentialWilson, A. (2015) · Metabolites · doi:10.3390/metabo5010140 · Cited by 242 · cited 1×
“When one or more gas concentration exceed a certain range or some speci fi c gases are produced, they often cause changes in the body ’ s disease or metabolic function 9 – 11 .”
BackgroundWang, C., Mbi, A., & Shepherd, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035730 · Cited by 236
Gas Classification Using Deep Convolutional Neural Networks
Peng, P., Zhao, X., Pan, X., & Ye, W. (2018) · Sensors · doi:10.3390/s18010157 · Cited by 222
Yoon, J.-W., & Lee, J.-H. (2017) · Lab Chip · doi:10.1039/c7lc00810d · Cited by 222
Analysis of Volatile Organic Compounds in the Exhaled Breath for the Diagnosis of Lung Cancer
Mazzone, P. J. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31817c7439 · Cited by 216 · cited 1×
“…(such as ethane, pentane, and iso-prene), oxygen-containing compounds (such as acetone, alcohols, and aldehydes), nitrogen-containing compounds (such as dimethylamine and trimethylamine) and sulfur-containing compounds (such as methyl mercaptan, ethyl mercaptan, and dimethyl sul fi de) 4,32 – 34 .”
BackgroundGas Recognition in E-Nose System: A Review
Chen, H., Huo, D., & Zhang, J. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3166530 · Cited by 216 · cited 6×
“…6,82,115,129,130 , linear discriminant analysis (LDA) 6,19,82,130,131 , support vector machine (SVM) 2,6,19,70,130,132,133 , decision tree (DT) 2,130 , K-nearest neighbor (KNN) 2,6,19,130,134 , cluster analysis (CA) 115 , canonical discriminant analysis (CDA) 115 , partial least squares…”
BackgroundMethodInfluentialChemoresistive materials for electronic nose: Progress, perspectives, and challenges
Park, S. Y., Kim, Y., Kim, T., Eom, T. H., Kim, S. Y., & Jang, H. W. (2019) · InfoMat · doi:10.1002/inf2.12029 · Cited by 214
Wearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208 · cited 1×
“Currently, more than 3000 different VOCs have been identi fi ed in breath samples 19,27 – 29 , with over 500 VOCs detected in single breath samples 27,30,31 .”
BackgroundBreath analysis: trends in techniques and clinical applications
Di Francesco, F., Fuoco, R., Trivella, M. G., & Ceccarini, A. (2005) · Microchemical Journal · doi:10.1016/j.microc.2004.10.008 · Cited by 206 · cited 1×
“In summary, breath analysis is a highly a promising medical detection technology 15 – 17 .”
BackgroundThe urea breath test for Helicobacter pylori.
Atherton, J. C., & Spiller, R. E. (1994) · Gut · doi:10.1136/gut.35.6.723 · Cited by 204 · cited 1×
“Signi fi cant changes in breath markers can be detected in many diseases, among which Helicobacter pylori breath detection has become a clinical basis 12,13 , and exhaled NO detection can also be used as an auxiliary means of asthma clinical 14 .”
BackgroundDevelopment of a LeNet-5 Gas Identification CNN Structure for Electronic Noses
Wei, G., Li, G., Zhao, J., & He, A. (2019) · Sensors · doi:10.3390/s19010217 · Cited by 199
Chemo-Electrical Gas Sensors Based on Conducting Polymer Hybrids
Park, S., Park, C., & Yoon, H. (2017) · Polymers · doi:10.3390/polym9050155 · Cited by 191 · cited 1×
“Common examples of CPs include polypyrrole (PPy), polyaniline (PANI), and polythiophene (PT) 102 – 104 .”
BackgroundSensors for Enhanced Detection of Acetone as a Potential Tool for Noninvasive Diabetes Monitoring
Rydosz, A. M. (2018) · Sensors · doi:10.3390/s18072298 · Cited by 180 · cited 1×
“At present, a range of MOS sensing materials, such as SnO 2 , ZnO, CuO, TiO 2 , WO 3 , NiO, In 2 O 3 , WO 3 , TiO 2 , Fe 2 O 3 , and MoO 3 , are commonly used to detect various gases, such as acetone, ethanol, formaldehyde, H 2 S, NH 3 , NO 2 , and CO 19,28,82,83 .”
BackgroundElectronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179 · cited 10×
“At present, a range of MOS sensing materials, such as SnO 2 , ZnO, CuO, TiO 2 , WO 3 , NiO, In 2 O 3 , WO 3 , TiO 2 , Fe 2 O 3 , and MoO 3 , are commonly used to detect various gases, such as acetone, ethanol, formaldehyde, H 2 S, NH 3 , NO 2 , and CO 19,28,82,83 .”
BackgroundMethodInfluentialExhaled breath analysis for lung cancer.
Dent, A. G., Sutedja, T. G., & Zimmerman, P. V. (2013) · PubMed · doi:10.3978/j.issn.2072-1439.2013.08.44 · Cited by 175
Chen, X., Cao, M., Li, Y., Hu, W., Wang, P., Ying, K., & Pan, H. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/8/001 · Cited by 166 · cited 1×
“9d. Chen et al. proposed a novel eNose model based on a virtual array SAW sensor 154 .”
MethodSelf-citationOlfactory systems for medical applications
DAMICO, A., DINATALE, C., PAOLESSE, R., MACAGNANO, A., MARTINELLI, E., PENNAZZA, G., SANTONICO, M., BERNABEI, M., ROSCIONI, C., & GALLUCCIO, G. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.09.044 · Cited by 166
Homayoonnia, S., & Zeinali, S. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.152 · Cited by 165 · cited 1×
“5d) 89 .”
Schwarz, K., Pizzini, A., Arendacká, B., Zerlauth, K., Filipiak, W., Schmid, A., Dzien, A., Neuner, S., Lechleitner, M., Scholl-Bürgi, S., et al. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027003 · Cited by 164 · cited 1×
“At present, proton transfer reaction-mass spectrometry (PTR-MS) 71 , selective ion fl ow tube-mass spectrometry (SIFT-MS) 72 and IMS-MS 73 are widely employed for exhaled gas analysis.”
MethodDas, S., Pal, S., & Mitra, M. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0164-6 · Cited by 164
Smolinska, A., Klaassen, E. M. M., Dallinga, J. W., van de Kant, K. D. G., Jobsis, Q., Moonen, E. J. C., van Schayck, O. C. P., Dompeling, E., & van Schooten, F. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095668 · Cited by 163 · cited 1×
“Currently, more than 3000 different VOCs have been identi fi ed in breath samples 19,27 – 29 , with over 500 VOCs detected in single breath samples 27,30,31 .”
BackgroundTraining and Validating a Portable Electronic Nose for Lung Cancer Screening
van de Goor, R. M. G. E., van Hooren, M. R. A., Dingemans, A. C., Kremer, B., & Kross, K. W. (2018) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2018.01.024 · Cited by 162
Chatterjee, S., Castro, M., & Feller, J. F. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20819b · Cited by 162 · cited 1×
“Chatterjee et al. developed an eNose system by integrating 5 carbon nanotube (CNT)-based CP nanocomposite (CPC) sensors with a CNT sensor 105 .”
MethodClinical utility of fractional exhaled nitric oxide in severe asthma management
Menzies-Gow, A. N., Mansur, A. H., & Brightling, C. E. (2020) · European Respiratory Journal · doi:10.1183/13993003.01633-2019 · Cited by 160 · cited 2×
“5a, the transient response to 10 ppm acetone was shown for three different samples and provided response/recovery times of approximately 15.2/9.6 s and 14.1/6.8 s for WO 3 /GNs and WO 3 /Pt-GNs, respectively.”
BackgroundInfluentialBreath Ammonia Analysis: Clinical Application and Measurement
Hibbard, T., & Killard, A. J. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.521729 · Cited by 157 · cited 1×
“Abnormal levels of ammonia in breath are associated with liver or kidney dysfunction 57 , which could also be used to diagnose peptic ulcers of the stomach or duodenum caused by Helicobacter pylori 58 .”
Backgroundvan Keulen, K. E., Jansen, M. E., Schrauwen, R. W. M., Kolkman, J. J., & Siersema, P. D. (2019) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.15622 · Cited by 153
Arasaradnam, R. P., Covington, J. A., Harmston, C., & Nwokolo, C. U. (2014) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.12657 · Cited by 151
Cevoli, C., Cerretani, L., Gori, A., Caboni, M. F., Toschi, T. G., & Fabbri, A. (2011) · Food Chemistry · doi:10.1016/j.foodchem.2011.05.126 · Cited by 148 · cited 1×
“The fi nal accuracy was 100% 148 .”
BackgroundLiu, W., Xie, Y., Chen, T., Lu, Q., Rehman, S. U., & Zhu, L. Z. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126871 · Cited by 148 · cited 1×
“5b) 92 .”
Surface Activity-Tuned Metal Oxide Chemiresistor: Toward Direct and Quantitative Halitosis Diagnosis
Shin, H., Kim, D., Jung, W., Jang, J., Kim, Y. H., Lee, Y., Chang, K.-Y., Lee, J., Park, J., Namkoong, K., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c01350 · Cited by 147
A novel method for diabetes diagnosis based on electronic nose
Wang, P., Yi, T., Haibao, X., & Farong, S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00059-6 · Cited by 146
Blood Ketone Bodies and Breath Acetone Analysis and Their Correlations in Type 2 Diabetes Mellitus
Saasa, V., Beukes, M., Lemmer, Y., & Mwakikunga, B. W. (2019) · Diagnostics · doi:10.3390/diagnostics9040224 · Cited by 144 · cited 2×
“The application of eNose in clinical medicine mainly includes early screening of various cancers 21 , lung diseases, such as pneumonia and upper respiratory tract infection 22 , diabetes 23 , identi fi cation of bacterial pathogens 24 , and microbial metabolites released from super fi cial wounds 25 .”
BackgroundRapid acetone detection using indium loaded WO3/SnO2 nanohybrid sensor
Tomer, V. K., Singh, K., Kaur, H., Shorie, M., & Sabherwal, P. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.179 · Cited by 142
Bulk and Surface Acoustic Wave Sensor Arrays for Multi-Analyte Detection: A Review
Länge, K. (2019) · Sensors · doi:10.3390/s19245382 · Cited by 141
Breath biomarkers for detection of human liver diseases: preliminary study
Sehnert, S. S., Jiang, L., Burdick, J. F., & Risby, T. H. (2002) · Biomarkers · doi:10.1080/13547500110118184 · Cited by 138 · cited 1×
“Various gases have different types, concentrations, volatilities, fat solubilities, diffusion rates in the blood circulation, passing rates through alveolar cell membranes, and other characteristics 8 .”
BackgroundHalitosis associated volatiles in breath of healthy subjects
den Velde, S. V., Quirynen, M., hee, P. V., & van Steenberghe, D. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.02.048 · Cited by 138 · cited 1×
“These conditions are associated with sulfur-containing compounds, such as hydrogen sul fi de, methyl mercaptan, and dimethyl sul fi de 64,65 .”
BackgroundBreath Acetone Sensors as Non-Invasive Health Monitoring Systems: A Review
Alizadeh, N., Jamalabadi, H., & Tavoli, F. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2942693 · Cited by 129 · cited 13×
“At present, a range of MOS sensing materials, such as SnO 2 , ZnO, CuO, TiO 2 , WO 3 , NiO, In 2 O 3 , WO 3 , TiO 2 , Fe 2 O 3 , and MoO 3 , are commonly used to detect various gases, such as acetone, ethanol, formaldehyde, H 2 S, NH 3 , NO 2 , and CO 19,28,82,83 .”
BackgroundMethodInfluentialAdvances in Mid-Infrared Spectroscopy-Based Sensing Techniques for Exhaled Breath Diagnostics
Selvaraj, R., Vasa, N. J., Nagendra, S. M. S., & Mizaikoff, B. (2020) · Molecules · doi:10.3390/molecules25092227 · Cited by 125
Analysis of biogenic volatile organic compounds in human health and disease
Dummer, J. F., Storer, M., Swanney, M. P., McEwan, M. J., Scott-Thomas, A., Bhandari, S., Chambers, S. T., Dweik, R. A., & Epton, M. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.03.011 · Cited by 123
Exhaled breath analysis in disease detection
Chen, T., Liu, T., Li, T., Zhao, H., & Chen, Q. (2020) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.12.036 · Cited by 123 · cited 1×
“In summary, breath analysis is a highly a promising medical detection technology 15 – 17 .”
BackgroundThe electronic nose technology in clinical diagnosis: A systematic review
Farraia, M., Rufo, J. C., Paciência, I., Mendes, F. C., Delgado, L., & Moreira, A. M. (2019) · Porto Biomedical Journal · doi:10.1097/j.pbj.0000000000000042 · Cited by 120 · cited 1×
“Notably, it has been applied in clinical medicine, including early screening of diverse cancers 75 , lung diseases 76 , diabetes 77 , bacterial pathogen identi fi cation 78,79 , and in the analysis of microbial metabolites from super fi cial wounds 25,80 .”
MethodExhaled breath biomarker sensing
Vasilescu, A., Hrinczenko, B. W., Swain, G. M., & Peteu, S. F. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113193 · Cited by 119
King, J., Unterkofler, K., Teschl, G., Teschl, S., Koc, H., Hinterhuber, H., & Amann, A. (2011) · Journal of Mathematical Biology · doi:10.1007/s00285-010-0398-9 · Cited by 117
Nurputra, D. K., Kusumaatmaja, A., Hakim, M. S., Hidayat, S. N., Julian, T., Sumanto, B., Mahendradhata, Y., Saktiawati, A. M. I., Wasisto, H. S., & Trıyana, K. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00661-2 · Cited by 116 · cited 5×
“In a related study, the outcomes of COVID-19 detection within a local hospital were detailed utilizing a developed electronic setup incorporating commercial VOC gas sensors 153 .”
BackgroundInfluentialXu, Y., Zheng, L., Chen, Y., Liu, X., & Zhang, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127237 · Cited by 116
The Measurement of Ammonia in Human Breath and its Potential in Clinical Diagnostics
Brannelly, N., Hamilton-Shield, J. P., & Killard, A. J. (2016) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2016.1153949 · Cited by 115
Breath analysis in critically ill patients: potential and limitations
Schubert, J. K., Miekisch, W., Geiger, K. K., & Nöldge‐Schomburg, G. (2004) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.4.5.619 · Cited by 110 · cited 1×
“Exhaled gases of healthy humans contain nitrogen, oxygen, carbon dioxide, water vapor, rare gases, and various compounds produced during metabolism 3 – 6 .”
BackgroundSearching for selected VOCs in human breath samples as potential markers of lung cancer
Rudnicka, J., Kowalkowski, T., & Buszewski, B. (2019) · Lung Cancer · doi:10.1016/j.lungcan.2019.02.012 · Cited by 108
Lekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105 · cited 4×
“By measuring the change in resonance frequency, the mass or concentration of a speci fi c gas adsorbed can be quanti fi ed 70,81 .”
BackgroundInfluentialDifferentiation between genetic mutations of breast cancer by breath volatolomics
Barash, O., Zhang, W., Halpern, J. M., Hua, Q., Pan, Y.-Y., Kayal, H., Khoury, K., Liu, H., Davies, M. P. A., & Haick, H. (2015) · Oncotarget · doi:10.18632/oncotarget.6269 · Cited by 104 · cited 2×
“Currently, more than 3000 different VOCs have been identi fi ed in breath samples 19,27 – 29 , with over 500 VOCs detected in single breath samples 27,30,31 .”
BackgroundArtificial Breath Classification Using XGBoost Algorithm for Diabetes Detection
Paleczek, A., Grochala, D., & Rydosz, A. M. (2021) · Sensors · doi:10.3390/s21124187 · Cited by 101 · cited 2×
“Its accuracy and recall rates were 99% and 100%, respectively, which were superior to those of other commonly used algorithms (such as SVM, KNN and DT) 136 .”
MethodInfluentialZakaria, A., Shakaff, A. Y. M., Masnan, M. J., Ahmad, M. N., Adom, A. H., Jaafar, M. N., Ghani, S. A., Abdullah, A. H., Aziz, A., Kamarudin, L. M., et al. (2011) · Sensors · doi:10.3390/s110807799 · Cited by 100
Liu, W., Sun, J., Xu, L. H., Zhu, S., Zhou, X., Yang, S., Dong, B., Bai, X., Lu, G., & Song, H. (2019) · Nanoscale Horizons · doi:10.1039/c9nh00404a · Cited by 99
Agapiou, A., Amann, A., Mochalski, P., Statheropoulos, M., & Thomas, C. L. P. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.11.018 · Cited by 98 · cited 1×
“Many studies have shown that acetone is one of the most abundant VOCs in human respiration 4,47 – 49 .”
BackgroundDetection of Barrett’s oesophagus through exhaled breath using an electronic nose device
Peters, Y., Schrauwen, R. W. M., Tan, A. C. I. T. L., Bogers, S., de Jong, B., & Siersema, P. D. (2020) · Gut · doi:10.1136/gutjnl-2019-320273 · Cited by 98
Guiding Ketogenic Diet with Breath Acetone Sensors
Güntner, A. T., Kompalla, J. F., Landis, H., Theodore, S. J., Geidl, B., Sievi, N. A., Kohler, M., Pratsinis, S. E., & Gerber, P. A. (2018) · Sensors · doi:10.3390/s18113655 · Cited by 97
Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data
Schwoebel, H., Schubert, R., Sklorz, M., Kischkel, S., Zimmermann, R., Schubert, J. K., & Miekisch, W. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5173-2 · Cited by 94 · cited 1×
“2b. Hydrocarbons are compounds derived from lipid per-oxidation 40 and can serve as biomarkers of oxidative stress 2 .”
BackgroundMoor, C. C., Oppenheimer, J. C., Nakshbandi, G., Aerts, J. G. J. V., Brinkman, P., der Zee, A. H. M., & Wijsenbeek, M. S. (2020) · European Respiratory Journal · doi:10.1183/13993003.02042-2020 · Cited by 93
AN ELECTRONIC ANALOG FOR THE OLFACTORY PROCESSES*†
Wilkens, W. F., & Hartman, J. D. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb45092.x · Cited by 91 · cited 1×
“eNose has a documented history dating back to 1964 145 , when Wilkens and Hartman used electrodes to chemically react with gases to simulate the olfactory process of organisms.”
BackgroundDetection of lung cancer with electronic nose and logistic regression analysis
Tirzïte, M., Bukovskis, M., Strazda, G., Jurka, N., & Taivans, I. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aae1b8 · Cited by 90
Chen, C., Lin, W.-C., & Yang, H. (2020) · Respiratory Research · doi:10.1186/s12931-020-1285-6 · Cited by 90
Allers, M., Langejuergen, J., Gaida, A., Holz, O., Schuchardt, S., Hohlfeld, J. M., & Zimmermann, S. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/2/026004 · Cited by 88 · cited 1×
“Currently, gas detection meth-ods utilizing GC primarily include thermal desorption-gas chromatography (TD-GC) 68 , gas chromatography-hydrogen fl ame ionization detector (GC-FID) 50 , gas chromatography-ion mobility spectrometry (GC-IMS) 69 and gas chromatography-mass spectrometry (GC-MS) 62 .”
MethodUse of Electronic Noses for Diagnosis of Digestive and Respiratory Diseases through the Breath
Sánchez, C., Santos, J. P., & Lozano, J. (2019) · Biosensors · doi:10.3390/bios9010035 · Cited by 85
Gholizadeh, A., Voiry, D., Weisel, C. P., Gow, A. J., Laumbach, R. J., Kipen, H. M., Chhowalla, M., & Javanmard, M. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.22 · Cited by 85 · cited 1×
“This type of sensor is particularly effective in detecting electrochemically active gases 113,114 .”
BackgroundSutaria, S. R., Gori, S. S., Morris, J. D., Xie, Z., Fu, X., & Nantz, M. H. (2022) · Metabolites · doi:10.3390/metabo12060561 · Cited by 85 · cited 1×
“Increased levels of reactive oxygen species in cancer cells promote lipid peroxidation, leading to the production of various aldehydes 55 .”
BackgroundColorimetric Sensor for Online Accurate Detection of Breath Acetone
Wang, D., Zhang, F., Prabhakar, A., Qin, X., Forzani, E., & Tao, N. J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02025 · Cited by 83 · cited 1×
“7f) 126,127 .”
van Geffen, W. H., Bruins, M., & Kerstjens, H. A. M. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/3/036001 · Cited by 79 · cited 1×
“Notably, it has been applied in clinical medicine, including early screening of diverse cancers 75 , lung diseases 76 , diabetes 77 , bacterial pathogen identi fi cation 78,79 , and in the analysis of microbial metabolites from super fi cial wounds 25,80 .”
MethodA review of algorithms for SAW sensors e-nose based volatile compound identification
Hotel, O., Poli, J.-P., Mer, C., Scorsone, E., & Saada, S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.09.040 · Cited by 79 · cited 3×
“Additionally, it is very sensitive to environmental factors, such as temperature and humidity, limiting its application 85,108 .”
BackgroundMethodChien, P.-J., Suzuki, T., Tsujii, M., Ye, M., Minami, I., Toda, K., Otsuka, H., Toma, K., Arakawa, T., Araki, K., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03191 · Cited by 79
Song, G., Jiang, D., Wu, J., Sun, X., Deng, M., Wang, L., Hao, C., Shi, J., Liu, H., Tian, Y., et al. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.135979 · Cited by 78
Kus, F., Altınkök, Ç., Zayim, E. Ö., Erdemir, S., Taşaltın, C., & Gürol, İ. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129402 · Cited by 73
Hsu, C., Chang‐Chien, G., Lin, S., Hou, C., Lu, P., & Tain, Y. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020336 · Cited by 69 · cited 1×
“2c2) 59 – 61 .”
Detection of ripeness grades of berries using an electronic nose
Aghilinategh, N., Dalvand, M. J., & Anvar, A. (2020) · Food Science & Nutrition · doi:10.1002/fsn3.1788 · Cited by 68 · cited 1×
“The Nahid group used an eNose system to classify the maturity of berries into fi ve levels in 2020 147 .”
MethodA systematic review of breath analysis and detection of volatile organic compounds in COPD
Christiansen, A. B., Davidsen, J. R., Titlestad, I. L., Vestbo, J., & Baumbach, J. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/3/034002 · Cited by 68 · cited 1×
“Speci fi cally, most of the VOCs in COPD are aldehydes or hydrocarbons 43 .”
BackgroundThe Most Common Methods for Breath Acetone Concentration Detection: A Review
Obeidat, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3074610 · Cited by 65 · cited 5×
“At present, a range of MOS sensing materials, such as SnO 2 , ZnO, CuO, TiO 2 , WO 3 , NiO, In 2 O 3 , WO 3 , TiO 2 , Fe 2 O 3 , and MoO 3 , are commonly used to detect various gases, such as acetone, ethanol, formaldehyde, H 2 S, NH 3 , NO 2 , and CO 19,28,82,83 .”
BackgroundMethodInfluentialJulian, T., Hidayat, S., Rianjanu, A., Dharmawan, A., Wasisto, H. S., & Triyana, K. (2020) · ACS Omega · doi:10.1021/acsomega.0c04433 · Cited by 65 · cited 1×
“It has received considerable attention due to its high precision and sensitivity 111,112 .”
BackgroundElectrochemical sensor system for breath analysis of aldehydes, CO and NO
Obermeier, J., Trefz, P., Wex, K., Sabel, B., Schubert, J. K., & Miekisch, W. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/1/016008 · Cited by 63
ZIF Nanocrystal-Based Surface Acoustic Wave (SAW) Electronic Nose to Detect Diabetes in Human Breath
Bahos, F. A., Sainz-Vidal, A., Sanchez-Perez, C. A., Saniger, J. M., Gràcia, I., Saniger‐Alba, M. D. M., & Matatagui, D. (2018) · Biosensors · doi:10.3390/bios9010004 · Cited by 60
Mukhopadhyay, R. (2004) · Analytical Chemistry · doi:10.1021/ac041600+ · Cited by 58
Siegel, A. P., Daneshkhah, A., Hardin, D. S., Shrestha, S., Varahramyan, K., & Agarwal, M. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa6ac6 · Cited by 58
Diouf, A., Bari, N. E., & Bouchikhi, B. (2019) · Talanta · doi:10.1016/j.talanta.2019.120577 · Cited by 56 · cited 1×
“This type of sensor is particularly effective in detecting electrochemically active gases 113,114 .”
BackgroundTammanoon, N., Wisitsoraat, A., Phokharatkul, D., Tuantranont, A., Phanichphant, S., Yordsri, V., & Liewhiran, C. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.238 · Cited by 56
Liangou, A., Tasoglou, A., Huber, H. J., Wistrom, C., Brody, K., Menon, P. G., Bebekoski, T., Menschel, K., Davidson-Fiedler, M., DeMarco, K., et al. (2021) · EClinicalMedicine · doi:10.1016/j.eclinm.2021.101207 · Cited by 55
Human biomarkers in breath by photoacoustic spectroscopy
Navas, M. J., Jiménez, A. M., & Asuero, A. G. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.04.008 · Cited by 55 · cited 1×
“Abnormal levels of ammonia in breath are associated with liver or kidney dysfunction 57 , which could also be used to diagnose peptic ulcers of the stomach or duodenum caused by Helicobacter pylori 58 .”
BackgroundNon-Invasive Method for Tuberculosis Exhaled Breath Classification Using Electronic Nose
Hendrick, H., Hidayat, R. S. A., Horng, G.-J., & Wang, Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3061616 · Cited by 54
Exhaled breath condensate volatilome allows sensitive diagnosis of persistent asthma
Rufo, J. C., Paciência, I., Mendes, F. C., Farraia, M., Rodolfo, A., Silva, D., Fernandes, E. D. O., Delgado, L., & Moreira, A. M. (2018) · Allergy · doi:10.1111/all.13596 · Cited by 51 · cited 15×
“This device could be used to detect 6 VOCs: pyridine, tetrahydrofuran, ethanol, methanol, acetic acid and ammonium hydroxide 107 .”
MethodInfluentialObstructive sleep apnoea – an update
Chan, A. S. L., Phillips, C. L., & Cistulli, P. A. (2010) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2009.02069.x · Cited by 50 · cited 1×
“Exhaled CO may be associated with obstructive sleep apnea (OSA), a common sleep-disordered breathing disorder characterized by recurrent complete or partial collapse of the upper airway during sleep 37 .”
BackgroundBedük, T., Durmus, C., Hanoglu, S. B., Beduk, D., Salama, K. N., Göksel, T., Turhan, K., & Tımur, S. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116329 · Cited by 50
Design and development of an e-nose system for the diagnosis of pulmonary diseases
Binson, V. A., & Subramoniam, M. (2021) · Acta of Bioengineering and Biomechanics · doi:10.37190/abb-01737-2020-03 · Cited by 49
Recent Trends in Exhaled Breath Diagnosis Using an Artificial Olfactory System
Kim, C., Raja, I. S., Lee, J., Lee, J.-H., Kang, M. S., Lee, S. H., Oh, J., & Han, D. (2021) · Biosensors · doi:10.3390/bios11090337 · Cited by 48
Li, J., Hannon, A., Yu, G. Y., Idziak, L. A., Sahasrabhojanee, A., Govindarajan, P., Maldonado, Y., Ngo, K., Abdou, J. P., Mai, N., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00367 · Cited by 47 · cited 1×
“In addition to the early cancer screening, bacterial pathogen identi fi cation and analysis of super fi cial wound micro-organisms mentioned in the manuscript, several research teams have also developed respiratory tests for COVID-19 in the last three years 156,157 .”
BackgroundRodríguez‐Aguilar, M., Ramírez‐García, S., Ilizaliturri-Hernandez, C. A., Gómez‐Gómez, A., Brussel, E. V., Díaz‐Barriga, F., Medellín‐Garibay, S. E., & Flores‐Ramírez, R. (2019) · Biomedical Chromatography · doi:10.1002/bmc.4684 · Cited by 46
Review of the algorithms used in exhaled breath analysis for the detection of diabetes
Paleczek, A., & Rydosz, A. M. (2022) · Journal of Breath Research · doi:10.1088/1752-7163/ac4916 · Cited by 44 · cited 12×
“…using classical machine learning algorithms, such as principal component analysis (PCA) 6,82,115,129,130 , linear discriminant analysis (LDA) 6,19,82,130,131 , support vector machine (SVM) 2,6,19,70,130,132,133 , decision tree (DT) 2,130 , K-nearest neighbor (KNN) 2,6,19,130,134 , cluster…”
BackgroundMethodInfluentialClinical studies of detecting COVID-19 from exhaled breath with electronic nose
Kwiatkowski, A., Borys, S., Sikorska, K., Drozdowska, K., & Smulko, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-20534-8 · Cited by 43 · cited 1×
“In a related study, the outcomes of COVID-19 detection within a local hospital were detailed utilizing a developed electronic setup incorporating commercial VOC gas sensors 153 .”
MethodElectronic nose in discrimination of children with uncontrolled asthma
Tenero, L., Sandri, M. F., Piazza, M., Paiola, G., Zaffanello, M., & PIACENTINI, G. L. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/ab9ab0 · Cited by 42
Boubin, M., & Shrestha, S. (2019) · Sensors · doi:10.3390/s19102283 · Cited by 42 · cited 1×
“…component analysis (PCA) 6,82,115,129,130 , linear discriminant analysis (LDA) 6,19,82,130,131 , support vector machine (SVM) 2,6,19,70,130,132,133 , decision tree (DT) 2,130 , K-nearest neighbor (KNN) 2,6,19,130,134 , cluster analysis (CA) 115 , canonical discriminant analysis (CDA) 115 ,…”
Licht, J.-C., & Grasemann, H. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21249416 · Cited by 41 · cited 1×
“Currently, more than 3000 different VOCs have been identi fi ed in breath samples 19,27 – 29 , with over 500 VOCs detected in single breath samples 27,30,31 .”
BackgroundYu, L., Su, F.-H., Ma, M.-Y., & Lv, Y. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3713-1 · Cited by 41 · cited 2×
“Currently, gas detection meth-ods utilizing GC primarily include thermal desorption-gas chromatography (TD-GC) 68 , gas chromatography-hydrogen fl ame ionization detector (GC-FID) 50 , gas chromatography-ion mobility spectrometry (GC-IMS) 69 and gas chromatography-mass spectrometry (GC-MS) 62 .”
BackgroundMethodDummer, J. F., Storer, M., Hu, W.-P., Swanney, M. P., Milne, G. J., FRAMPTON, C. M. A., Scotter, J., Prisk, G. K., & Epton, M. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/4/046001 · Cited by 39 · cited 1×
“At present, proton transfer reaction-mass spectrometry (PTR-MS) 71 , selective ion fl ow tube-mass spectrometry (SIFT-MS) 72 and IMS-MS 73 are widely employed for exhaled gas analysis.”
MethodDetection of lung cancer with electronic nose using a novel ensemble learning framework
Lei, L., Li, W., He, Z., Chen, W., Liu, H., Chen, K., & Pi, X. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abe5c9 · Cited by 34 · cited 2×
“Ensemble learning is a machine learning strategy independent of the algorithm 135 .”
BackgroundMethodA Metal Oxide Gas Sensors Array for Lung Cancer Diagnosis Through Exhaled Breath Analysis
Marzorati, D., Mainardi, L. T., Sedda, G., Gasparri, R., Spaggiari, L., & Cerveri, P. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856750 · Cited by 33
Marzorati, D., Mainardi, L. T., Sedda, G., Gasparri, R., Spaggiari, L., & Cerveri, P. (2021) · Chemosensors · doi:10.3390/chemosensors9080209 · Cited by 33 · cited 1×
“The accuracy rates were 92%, 88.24%, 94.87% and 84.24%, respectively 142,143 .”
InfluentialNazir, N. U., Abbas, S. R., Nasir, H., & Hussaın, I. (2021) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2021.115977 · Cited by 33 · cited 4×
“Tarik ’ s research team performed noninvasive diagnosis of chronic kidney disease, diabetes, and H subjects using eNose and GC-MS coupled analysis 63 .”
ResultInfluentialLong-term monitoring of breath methane
Polag, D., & Keppler, F. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.12.097 · Cited by 31
Mechanisms linking metabolism of Helicobacter pylori to 18O and 13C-isotopes of human breath CO2
Som, S., De, A., Banik, G. D., Maity, A., Ghosh, C., Pal, M., Daschakraborty, S. B., Chaudhuri, S., Jana, S., & Pradhan, M. (2015) · Scientific Reports · doi:10.1038/srep10936 · Cited by 28
Li, Y., Li, J., & Xu, H. (2017) · RSC Advances · doi:10.1039/c6ra25453e · Cited by 27 · cited 1×
“Nanostructured materials, such as nanowires, nanosh-eets, nanospheres, and nanopetals, have been used for VOC detection 87 – 90 , 91 , and composite metal oxides, such as La 2 O 3 -SnO 2 , In-WO 3 - SnO 2 , and ZnO-SnO 297 – 99 .”
MethodSelf-citationSánchez, C., Santos, J. P., Lozano, J., Sayago, I., Sanjurjo, J. L., Azabal, A., & Ruiz-Valdepeñas, S. (2020) · Sensors · doi:10.3390/s20247223 · Cited by 27
Cavity ringdown spectroscopy of nitric oxide in the ultraviolet region for human breath test
Ai, Y., Li, J., Li, Q., Sun, M., Li, Y., & Wang, C. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/ab8184 · Cited by 26 · cited 1×
“…COPD 2,7,160 , asthma 2,160 , ulcerative colitis 10 0~10 ppb 161 Pentane COPD 2 , asthma Exhaled NO detection has been approved by the U.S. Food and Drug Administration as a diagnostic criterion for asthma, thus positioning it as a valuable adjunctive tool for asthma assessment and treatment 36 .”
MethodSelf-citationA conductive liquid-based surface acoustic wave device
Nam, J., & Lim, C. S. (2016) · Lab on a Chip · doi:10.1039/c6lc00827e · Cited by 23 · cited 1×
“Additionally, it is very sensitive to environmental factors, such as temperature and humidity, limiting its application 85,108 .”
BackgroundBagchi, S., Sengupta, S., & Mondal, S. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2649686 · Cited by 21
Jeon, J. M., Choi, J.-S., Yu, J.-B., Lee, H.-R., Jang, B. K., & Byun, H. (2018) · ETRI Journal · doi:10.4218/etrij.2017-0018 · Cited by 20 · cited 1×
“Jin et al. selected four kinds of semiconductor chemical sensors with different sensitive materials (Au/N-SnO 2 , Au/N-WO 3 , N-WO 3 and N-SnO 2 ) and constructed a 20-sensor array operating at fi ve different temperatures (245, 285, 310, 325, and 340 °C) 144 .”
BackgroundAmmonia Sensing and a Cross Sensitivity Evaluation with Atmosphere Gases using Optical Fiber Sensor
Manap, H., Muda, R., O’Keeffe, S., & Lewis, E. (2009) · Procedia Chemistry · doi:10.1016/j.proche.2009.07.239 · Cited by 17
Zhang, H., Ye, W., Zhao, X., Teng, R. K. F., & Pan, X. (2018) · IEEE International Conference on Electron Devices and Solid-State Circuits (EDSSC) · doi:10.1109/edssc.2018.8487105 · Cited by 17 · cited 1×
“The commonly used neural networks in the eNose systems are arti fi cial neural networks (ANNs) 115 , multilayer perceptron neural networks (MLPs) 138 , convolutional neural networks (CNNs) 138 – 140 , and radial basis functions (RBFs) 115 .”
MethodAcetone gas sensing features of zinc oxide/tin dioxide nanocomposite for diagnosis of diabetes
Asal, M., & Nasirian, S. (2019) · Materials Research Express · doi:10.1088/2053-1591/ab332c · Cited by 15 · cited 1×
“Nanostructured materials, such as nanowires, nanosh-eets, nanospheres, and nanopetals, have been used for VOC detection 87 – 90 , 91 , and composite metal oxides, such as La 2 O 3 -SnO 2 , In-WO 3 - SnO 2 , and ZnO-SnO 297 – 99 .”
MethodKuch'yanov, A. S., Chubakov, P. A., & Plekhanov, A. I. (2015) · Optics Communications · doi:10.1016/j.optcom.2015.04.045 · Cited by 13 · cited 1×
“They also have the ability to monitor chemical and physical parameters on a large scale 122 – 124 .”
BackgroundExhaled carbon monoxide levels in obstructive sleep apnoea
Kis, A., Mészáros, M., Tárnoki, D. L., Tárnoki, Á. D., Lázár, Z., Horváth, P., Kunos, L., & Bikov, A. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/ab231d · Cited by 13 · cited 3×
“Exhaled CO may be associated with obstructive sleep apnea (OSA), a common sleep-disordered breathing disorder characterized by recurrent complete or partial collapse of the upper airway during sleep 37 .”
BackgroundMeasurement of Exhaled Nitric Oxide in 456 Lung Cancer Patients Using a Ringdown FENO Analyzer
Li, J., Li, Q., Wei, X. L., Chen, Q., Sun, M., & Li, Y. (2021) · Metabolites · doi:10.3390/metabo11060352 · Cited by 11
Self-citationOzato, N., Saito, S., Yamaguchi, T. F., Katashima, M., Tokuda, I., Sawada, K., Katsuragi, Y., Kakuta, M., Imoto, S., Ihara, K., et al. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/ab61c6 · Cited by 11
Pirozzi, C. S., Sturrock, A., Carey, P., Whipple, S., Haymond, H., Baker, J., Weng, H.-Y., Greene, T., Scholand, M. B., Kanner, R. E., et al. (2015) · COPD Research and Practice · doi:10.1186/s40749-015-0004-z · Cited by 10
Volatile Organic Compounds in Human Breath
Karunagaran, M., Ramani, P., Gheena, S., Ramasubramanian, A., & Hannah, R. (2022) · Indian Journal of Dental Research · doi:10.4103/ijdr.ijdr_493_20 · Cited by 6 · cited 1×
“Ethanol and methanol in the human body are derived from microbial fermentation of carbohydrates in the gastrointestinal tract 34,54 .”
Background
Metadata
- Authors
- Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R.
- Venue
- Microsystems & Nanoengineering
- Published
- 2023-10-11
- Volume
- 9
- Issue
- 1
- Pages
- 129-129
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W4387519320
- Cited by
- 165
- References
- 153
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.