Microneedle-array patches loaded with dual mineralized protein/peptide particles for type 2 diabetes therapy
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The delivery of therapeutic peptides for diabetes therapy is compromised by short half-lives of drugs with the consequent need for multiple daily injections that reduce patient compliance and increase treatment cost. In this study, we demonstrate a smart exendin-4 (Ex4) delivery device based on microneedle (MN)-array patches integrated with dual mineralized particles separately containing Ex4 and glucose oxidase (GOx). The dual mineralized particle-based system can specifically release Ex4 while immobilizing GOx as a result of the differential response to the microenvironment induced by biological stimuli. In this manner, the system enables glucose-responsive and closed-loop release to significantly improve Ex4 therapeutic performance. Moreover, integration of mineralized particles can enhance the mechanical strength of alginate-based MN by crosslinking to facilitate skin penetration, thus supporting painless and non-invasive transdermal administration. We believe this smart glucose-responsive Ex4 delivery holds great promise for type 2 diabetes therapy by providing safe, long-term, and on-demand Ex4 therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global estimates of the prevalence of diabetes for 2010 and 2030
Shaw, J. E., Sicree, R. A., & Zimmet, P. Z. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.007 · Cited by 7,216
Dose translation from animal to human studies revisited.
Reagan‐Shaw, S., Nihal, M., & Ahmad, N. (2008) · The FASEB Journal · doi:10.1096/fj.07-9574lsf · Cited by 6,524
Drucker, D. J., & Nauck, M. A. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69705-5 · Cited by 3,896
Prediabetes: a high-risk state for diabetes development
Tabák, A. G., Herder, C., Rathmann, W., Brunner, E. J., & Kivimäki, M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60283-9 · Cited by 2,958
Type 2 diabetes: principles of pathogenesis and therapy
Stumvoll, M., Goldstein, B. J., & van Haeften, T. W. (2005) · The Lancet · doi:10.1016/s0140-6736(05)61032-x · Cited by 2,662
DeFronzo, R. A., Ratner, R. E., Han, J., Kim, D. D., Fineman, M. S., & Baron, A. D. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1092 · Cited by 1,559
Relationship of Depression and Diabetes Self-Care, Medication Adherence, and Preventive Care
Lin, E. H. B., Katon, W., Von Korff, M., Rutter, C., Simon, G. E., Oliver, M., Ciechanowski, P., Ludman, E. J., Bush, T., & Young, B. (2004) · Diabetes Care · doi:10.2337/diacare.27.9.2154 · Cited by 1,146
Drucker, D. J., Buse, J. B., Taylor, K., Kendall, D. M., Trautmann, M., Zhuang, D., & Porter, L. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61206-4 · Cited by 1,070
Elliott, R. M., Morgan, L. M., Tredger, J. A., Deacon, S., Wright, J., & Marks, V. (1993) · Journal of Endocrinology · doi:10.1677/joe.0.1380159 · Cited by 695
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Cited by
Fu, L., Wan, Y., Qi, C., He, J., Li, C., Yang, C., Xu, H., Lin, J., & Huang, P. (2021) · Advanced Materials · doi:10.1002/adma.202006892 · Cited by 820
Self-citationGlucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604
Self-citationCurrent trends in polymer microneedle for transdermal drug delivery
Ahmed Saeed AL-Japairai, K., Mahmood, S., Hamed Almurisi, S., Reddy Venugopal, J., Rebhi Hilles, A., Azmana, M., & Raman, S. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119673 · Cited by 448
Fu, L.-H., Hu, Y.-R., Qi, C., He, T., Jiang, S., Jiang, C., He, J., Qu, J., Lin, J., & Huang, P. (2019) · ACS Nano · doi:10.1021/acsnano.9b05836 · Cited by 437
Self-citationYin, M., Wu, J., Deng, M., Wang, P., Ji, G., Wang, M., Zhou, C., Blum, N. T., Zhang, W., Shi, H., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c06036 · Cited by 380
Recent advances of microneedles for biomedical applications: drug delivery and beyond
Yang, J., Liu, X., Fu, Y., & Song, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.03.007 · Cited by 378
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Self-citationPolymeric microneedles for transdermal protein delivery
Ye, Y., Yu, J., Wen, D., Kahkoska, A. R., & Gu, Z. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.01.015 · Cited by 324
Glucose‐Responsive Insulin and Delivery Systems: Innovation and Translation
Wang, J., Wang, Z., Yu, J., Kahkoska, A. R., Buse, J. B., & Gu, Z. (2020) · Advanced Materials · doi:10.1002/adma.201902004 · Cited by 295
Self-citationStimuli-responsive transdermal microneedle patches
Makvandi, P., Jamaledin, R., Chen, G., Baghbantaraghdari, Z., Zare, E. N., Di Natale, C., Onesto, V., Vecchione, R., Lee, J., Tay, F. R., et al. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.012 · Cited by 283
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
A microneedle vaccine printer for thermostable COVID-19 mRNA vaccines
vander Straeten, A., Sarmadi, M., Daristotle, J. L., Kanelli, M., Tostanoski, L. H., Collins, J., Pardeshi, A., Han, J., Varshney, D., Eshaghi, B., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01774-z · Cited by 189
“MNPs are typically handmade individually with labor-intensive, manual and imprecise steps, such as centrifugation, which makes consistent, automated manufacturing using these methods challenging 21 .”
Bi, D., Qu, F., Xiao, W., Wu, J., Liu, P., Du, H., Xie, Y., Liu, H., Zhang, L., Tao, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c08979 · Cited by 185
Self-citationAssisted 3D printing of microneedle patches for minimally invasive glucose control in diabetes
Wu, M., Zhang, Y., Huang, H., Li, J., Liu, H., Guo, Z., Xue, L., Liu, S., & Lei, Y. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111299 · Cited by 171
Metadata
- Authors
- Chen, W., Tian, R., Xu, C., Yung, B. C., Wang, G., Liu, Y., Ni, Q., Zhang, F., Zhou, Z., Wang, J., Niu, G., Ma, Y., Fu, L., & Chen, X.
- Venue
- Nature Communications
- Published
- 2017-11-24
- Volume
- 8
- Issue
- 1
- Pages
- 1777-1777
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2770663526
- Cited by
- 212
- References
- 11
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.