The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Inkjet-printed stretchable and low voltage synaptic transistor array
Open accessAbstract
Wearable and skin electronics benefit from mechanically soft and stretchable materials to conform to curved and dynamic surfaces, thereby enabling seamless integration with the human body. However, such materials are challenging to process using traditional microelectronics techniques. Here, stretchable transistor arrays are patterned exclusively from solution by inkjet printing of polymers and carbon nanotubes. The additive, non-contact and maskless nature of inkjet printing provides a simple, inexpensive and scalable route for stacking and patterning these chemically-sensitive materials over large areas. The transistors, which are stable at ambient conditions, display mobilities as high as 30 cm 2 V−1 s−1 and currents per channel width of 0.2 mA cm−1 at operation voltages as low as 1 V, owing to the ionic character of their printed gate dielectric. Furthermore, these transistors with double-layer capacitive dielectric can mimic the synaptic behavior of neurons, making them interesting for conformal brain-machine interfaces and other wearable bioelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationThe rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Self-citationA bioinspired flexible organic artificial afferent nerve
Kim, Y., Chortos, A., Xu, W., Liu, Y., Oh, J. Y., Son, D., Kang, J., Foudeh, A. M., Zhu, C., Lee, Y., et al. (2018) · Science · doi:10.1126/science.aao0098 · Cited by 1,466
Self-citationStretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Cited by
A New Frontier of Printed Electronics: Flexible Hybrid Electronics
Khan, Y., Thielens, A., Muin, S., Ting, J., Baumbauer, C., & Arias, A. C. (2020) · Advanced Materials · doi:10.1002/adma.201905279 · Cited by 891
Neuromorphic sensorimotor loop embodied by monolithically integrated, low-voltage, soft e-skin
Wang, W., Jiang, Y., Zhong, D., Zhang, Z., Choudhury, S., Lai, J.-C., Gong, H., Niu, S., Yan, X., Zheng, Y., et al. (2023) · Science · doi:10.1126/science.ade0086 · Cited by 788
Self-citationLiu, K., Ouyang, B., Guo, X., Guo, Y., & Liu, Y. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00133-3 · Cited by 554
Monolithic optical microlithography of high-density elastic circuits
Zheng, Y.-Q., Liu, Y., Zhong, D., Nikzad, S., Liu, S., Yu, Z., Liu, D., Wu, H.-C., Zhu, C., Li, J., et al. (2021) · Science · doi:10.1126/science.abh3551 · Cited by 401
Self-citationStable and Biocompatible Carbon Nanotube Ink Mediated by Silk Protein for Printed Electronics
Liang, X., Li, H., Dou, J., Wang, Q., He, W., Wang, C., Li, D., Lin, J., & Zhang, Y. (2020) · Advanced Materials · doi:10.1002/adma.202000165 · Cited by 323
Metadata
- Authors
- Molina-Lopez, F., Gao, T. Z., Kraft, U., Zhu, C., Öhlund, T., Pfattner, R., Feig, V. R., Kim, Y., Wang, S., Yun, Y., & Bao, Z.
- Venue
- Nature Communications
- Published
- 2019-06-18
- Volume
- 10
- Issue
- 1
- Pages
- 2676-2676
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2951672192
- Cited by
- 296
- References
- 4
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inkjet-printed stretchable and low voltage synaptic transistor array. https://app.cochat.ai/papers/10.1038/s41467-019-10569-3
- The paper
- Molina-Lopez, F., Gao, T. Z., Kraft, U., Zhu, C., Öhlund, T., Pfattner, R., Feig, V. R., Kim, Y., Wang, S., Yun, Y., & Bao, Z. (2019). Inkjet-printed stretchable and low voltage synaptic transistor array. Nature Communications. https://doi.org/10.1038/s41467-019-10569-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.