Integrating electric field modeling and neuroimaging to explain inter-individual variability of tACS effects
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Transcranial electrical stimulation (tES) of the brain can have variable effects, plausibly driven by individual differences in neuroanatomy and resulting differences of the electric fields inside the brain. Here, we integrated individual simulations of electric fields during tES with source localization to predict variability of transcranial alternating current stimulation (tACS) aftereffects on α-oscillations. In two experiments, participants received 20-min of either α-tACS (1 mA) or sham stimulation. Magnetoencephalogram (MEG) was recorded for 10-min before and after stimulation. tACS caused a larger power increase in the α-band compared to sham. The variability of this effect was significantly predicted by measures derived from individual electric field modeling. Our results directly link electric field variability to variability of tACS outcomes, underline the importance of individualizing stimulation protocols, and provide a novel approach to analyze tACS effects in terms of dose-response relationships.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
Dynamic imaging of coherent sources: studying neural interactions in the human brain
Gross, J., Kujala, J., Hämäläinen, M., Timmermann, L., Schnitzler, A., & Salmelin, R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.694 · Cited by 1,810
Spectral fingerprints of large-scale neuronal interactions
Siegel, M., Donner, T. H., & Engel, A. K. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3137 · Cited by 1,295
Effects of mental fatigue on attention: An ERP study
Boksem, M. A. S., Meijman, T. F., & Lorist, M. M. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2005.04.011 · Cited by 1,088
Thielscher, A., Antunes, A., & Saturnino, G. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318340 · Cited by 942
Endogenous electric fields may guide neocortical network activity
Fröhlich, F., & McCormick, D. A. (2010) · Neuron · doi:10.1016/j.neuron.2010.06.005 · Cited by 913
Vigilance, alertness, or sustained attention: physiological basis and measurement
Oken, B. S., Salinsky, M. C., & Elsas, S. M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.01.017 · Cited by 887
Ridding, M. C., & Ziemann, U. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.190314 · Cited by 787
Direct effects of transcranial electric stimulation on brain circuits in rats and humans
Vöröslakos, M., Takeuchi, Y., Brinyiczki, K., Zombori, T., Oliva, A., Fernández-Ruiz, A., Kozák, G., Kincses, Z. T., Iványi, B., Buzsáki, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02928-3 · Cited by 735
Horvath, J. C., Forte, J. D., & Carter, O. (2015) · Brain Stimulation · doi:10.1016/j.brs.2015.01.400 · Cited by 609
State-dependency in brain stimulation studies of perception and cognition
Silvanto, J., Muggleton, N., & Walsh, V. (2008) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2008.09.004 · Cited by 572
EEG oscillations: from correlation to causality
Herrmann, C. S., Strüber, D., Helfrich, R. F., & Engel, A. K. (2016) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2015.02.003 · Cited by 527
Self-citation
Cited by
Elyamany, O., Leicht, G., Herrmann, C. S., & Mulert, C. (2021) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-020-01209-9 · Cited by 310
Self-citationInferring Causality from Noninvasive Brain Stimulation in Cognitive Neuroscience
Bergmann, T. O., & Hartwigsen, G. (2021) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01591 · Cited by 264
Wischnewski, M., Alekseichuk, I., & Opitz, A. (2023) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2022.11.013 · Cited by 246
“Personalizing tACS frequencies to individual brain rhythms could further reduce variability and improve tACS efficacy [146].”
Non-invasive brain stimulation and neuroenhancement
Antal, A., Luber, B., Brem, A.-K., Bikson, M., Brunoni, A. R., Cohen Kadosh, R., Dubljević, V., Fecteau, S., Ferreri, F., Flöel, A., et al. (2022) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2022.05.002 · Cited by 220
“…brain activity recording and treat-ment adjustment, wearables to track physiological parameters (e.g., heart rate, sleep patterns), as well as analytical methods for the creation of individual target maps accounting for differences in anatomy and function (Kasten et al., 2019; Ruffini et al., 2020).”
MethodSelf-citationVergallito, A., Feroldi, S., Pisoni, A., & Romero Lauro, L. J. (2022) · Brain Sciences · doi:10.3390/brainsci12050522 · Cited by 179
Metadata
- Authors
- Kasten, F. H., Duecker, K., Maack, M. C., Meiser, A., & Herrmann, C. S.
- Venue
- Nature Communications
- Published
- 2019-11-28
- Volume
- 10
- Issue
- 1
- Pages
- 5427-5427
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2991555451
- Cited by
- 213
- References
- 14
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.