Machine learning-based prediction of acute coronary syndrome using only the pre-hospital 12-lead electrocardiogram
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Prompt identification of acute coronary syndrome is a challenge in clinical practice. The 12-lead electrocardiogram (ECG) is readily available during initial patient evaluation, but current rule-based interpretation approaches lack sufficient accuracy. Here we report machine learning-based methods for the prediction of underlying acute myocardial ischemia in patients with chest pain. Using 554 temporal-spatial features of the 12-lead ECG, we train and test multiple classifiers on two independent prospective patient cohorts (n = 1244). While maintaining higher negative predictive value, our final fusion model achieves 52% gain in sensitivity compared to commercial interpretation software and 37% gain in sensitivity compared to experienced clinicians. Such an ultra-early, ECG-based clinical decision support tool, when combined with the judgment of trained emergency personnel, would help to improve clinical outcomes and reduce unnecessary costs in patients with chest pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649 · cited 1×
“We used DeLong ’ s non-parametric approach to compare two ROC curves derived from related sample, with a p value of 0.05 (two-sided) indicating a signi fi cant difference between two diagnostic tests 42 .”
MethodInfluentialHeart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Self-citationFourth universal definition of myocardial infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., White, H. D., ESC Scientific Document Group, Thygesen, K., Alpert, J. S., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy462 · Cited by 5,880
Lusis, A. J. (2000) · Nature · doi:10.1038/35025203 · Cited by 4,839
Update on acute coronary syndromes: the pathologists' view
Falk, E., Nakano, M., Bentzon, J. F., Finn, A. V., & Virmani, R. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs411 · Cited by 1,047
Sample size estimation in diagnostic test studies of biomedical informatics
Hajian-Tilaki, K. (2014) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2014.02.013 · Cited by 995 · cited 1×
“To estimate the minimum sample size required for adequate AUC analysis of new diagnostic tests, we used the methods described by Hajian-Tilaki 40 .”
MethodA Tale of Coronary Artery Disease and Myocardial Infarction
Nabel, E. G., & Braunwald, E. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1112570 · Cited by 994 · cited 1×
“Critical narrowing or occlusion of a coronary artery leads to myocardial ischemia in the region supplied by that coronary artery 4,5 .”
BackgroundAcharya, U. R., Fujita, H., Oh, S. L., Hagiwara, Y., Tan, J. H., & Adam, M. (2017) · Information Sciences · doi:10.1016/j.ins.2017.06.027 · Cited by 937
Strategies for Reducing the Door-to-Balloon Time in Acute Myocardial Infarction
Bradley, E. H., Herrin, J., Wang, Y., Barton, B. A., Webster, T. R., Mattera, J. A., Roumanis, S. A., Curtis, J. P., Nallamothu, B. K., Magid, D. J., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmsa063117 · Cited by 839 · cited 1×
“This means that our algorithm can be used by non-specialized emergency personnel to screen patients and identify the subset of patients whose ECGs need to be further evaluated by offsite experts, a strategy that has long been shown to improve outcomes in those with con fi rmed ACS 22 .”
MethodLeening, M. J. G., Vedder, M. M., Witteman, J. C. M., Pencina, M. J., & Steyerberg, E. W. (2014) · Annals of Internal Medicine · doi:10.7326/m13-1522 · Cited by 594
Shah, A. S. V., Anand, A., Sandoval, Y., Lee, K. K., Smith, S. W., Adamson, P. D., Chapman, A. R., Langdon, T., Sandeman, D., Vaswani, A., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00391-8 · Cited by 510
Classification of myocardial infarction with multi-lead ECG signals and deep CNN
Baloglu, U. B., Talo, M., Yildirim, O., Tan, R. S., & Acharya, U. R. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2019.02.016 · Cited by 473
Acute Coronary Syndromes: Diagnosis and Management, Part I
Kumar, A., & Cannon, C. P. (2009) · Mayo Clinic Proceedings · doi:10.4065/84.10.917 · Cited by 377
Acute Coronary Syndromes: Diagnosis and Management, Part II
Kumar, A., & Cannon, C. P. (2009) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)60674-5 · Cited by 336
Multiscale Energy and Eigenspace Approach to Detection and Localization of Myocardial Infarction
Sharma, L. N., Tripathy, R. K., & Dandapat, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2405134 · Cited by 296
Lukas, A., & Antzelevitch, C. (1993) · Circulation · doi:10.1161/01.cir.88.6.2903 · Cited by 274 · cited 1×
“The following 65 features were identified: (1) amplitude of J+80 and T wave from each of the 12 leads (k= 24); (2) QRS, JTend, JTpeak, Tpeak-end, and QT interval measures (k= 6); (3) QRS and T axis in the frontal plane (k= 2); (4) spatial angle between QRS and T waveforms (k= 6); (5) inflection, amplitude, and slope o…”
BackgroundClassification of ECG signals using machine learning techniques: A survey
Jambukia, S. H., Dabhi, V. K., & Prajapati, H. B. (2015) · 2015 International Conference on Advances in Computer Engineering and Applications · doi:10.1109/icacea.2015.7164783 · Cited by 248
ECG Analysis Using Multiple Instance Learning for Myocardial Infarction Detection
Sun, L., Lu, Y., Yang, K., & Li, S. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2213597 · Cited by 241
Acharya, U. R., Fujita, H., Sudarshan, V. K., Oh, S. L., Adam, M., Koh, J. E. W., Tan, J. H., Ghista, D. N., Martis, R. J., Chua, C. K., et al. (2016) · Knowledge-Based Systems · doi:10.1016/j.knosys.2016.01.040 · Cited by 241
‘Ten Commandments’ for the Fourth Universal Definition of Myocardial Infarction 2018
Thygesen, K. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy856 · Cited by 239
Detection and Localization of Myocardial Infarction using K-nearest Neighbor Classifier
Arif, M., Malagore, I. A., & Afsar, F. A. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9474-3 · Cited by 223
Prospective validation of artificial neural network trained to identify acute myocardial infarction
Baxt, W. G., & Skora, J. (1996) · The Lancet · doi:10.1016/s0140-6736(96)91555-x · Cited by 214
Acute Myocardial Infarction Detected in the 12-Lead ECG by Artificial Neural Networks
Hedén, B., Öhlin, H., Rittner, R., & Edenbrandt, L. (1997) · Circulation · doi:10.1161/01.cir.96.6.1798 · Cited by 174
Detecting and interpreting myocardial infarction using fully convolutional neural networks
Strodthoff, N., & Strodthoff, C. (2019) · Physiological Measurement · doi:10.1088/1361-6579/aaf34d · Cited by 172
Lui, H. W., & Chow, K. L. (2018) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2018.08.002 · Cited by 152 · cited 1×
“Most prior algorithms 23 – 34 have used the open-source PTB diagnostic ECG database.”
MethodLiu, B., Liu, J., Wang, G., Huang, K., Fan, L., Zheng, Y., Luo, Y., & Zhou, F. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.08.010 · Cited by 139
Green, M., Björk, J., Forberg, J. L., Ekelund, U. E. G., Edenbrandt, L., & Ohlsson, M. (2006) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2006.07.006 · Cited by 129
Diagnosis of Acute Coronary Syndrome with a Support Vector Machine
Berikol, G. B., Yıldız, O., & Özcan, İ. T. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0432-6 · Cited by 122 · cited 1×
“T amplitude changes) with a full range of other clinical data elements (e.g., patient history, physical exam abnormalities, laboratory values, and/or diagnostic tests) 10,15,17,35 .”
BackgroundGoto, S., Kimura, M., Katsumata, Y., Goto, S., Kamatani, T., Ichihara, G., Ko, S., Sasaki, J., Fukuda, K., & Sano, M. (2019) · PLoS ONE · doi:10.1371/journal.pone.0210103 · Cited by 97
Using classification tree and logistic regression methods to diagnose myocardial infarction.
Tsien, C. L., Fraser, H., Long, W. J., & Kennedy, R. L. (1998) · PubMed · Cited by 91
Detection of inferior myocardial infarction using shallow convolutional neural networks
Reasat, T., & Shahnaz, C. (2017) · IEEE Region Humanitarian Technology Conference · doi:10.1109/r10-htc.2017.8289058 · Cited by 89
Wu, C.-C., Hsu, W., Islam, M. M., Poly, T. N., Yang, H., Nguyen, P., Wang, Y., & Li, Y. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.01.013 · Cited by 85
Point-of-Care Troponin Testing during Ambulance Transport to Detect Acute Myocardial Infarction
Stopyra, J. P., Snavely, A. C., Scheidler, J. F., Smith, L. M., Nelson, R. D., Winslow, J. E., Pomper, G. J., Ashburn, N. P., Hendley, N., Riley, R. F., et al. (2020) · Prehospital Emergency Care · doi:10.1080/10903127.2020.1721740 · Cited by 48
Usefulness of serial electrocardiograms for diagnosis of acute myocardial infarction
Ohlsson, M., Öhlin, H., Wallerstedt, S. M., & Edenbrandt, L. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01722-2 · Cited by 43
Forberg, J. L., Green, M., Björk, J., Ohlsson, M., Edenbrandt, L., Öhlin, H., & Ekelund, U. E. G. (2008) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2008.07.010 · Cited by 40 · cited 2×
“Although LR classi fi er developed by Forberg et al. (AUC = 0.88) performed better compared with ours (AUC = 0.79), it is worth noting that their approach selectively recruited positive cases to enrich their dataset for ACS, making their classes arti fi cially better balanced compared with ours (ACS prevalence = 40% vs.…”
BackgroundInfluentialAnalysis of ECG signal by chaos principle to help automatic diagnosis of myocardial infarction
Lahiri, T., Kumar, U., Mishra, H., Sarkar, S., & Roy, A. D. (2009) · Journal of Scientific & Industrial Research · Cited by 38
Al‐Zaiti, S. S., Martin‐Gill, C., Sejdić, E., Alrawashdeh, M., & Callaway, C. W. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2015.08.014 · Cited by 30
Self-citationAl‐Zaiti, S. S., Sejdić, E., Němec, J., Callaway, C. W., Soman, P., & Lux, R. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1659-1 · Cited by 27 · cited 1×
“We have shown that mild-to-moderate ischemia distorts the temporal – spatial features of the 12-lead ECG before ST changes evolve 8,9 , suggesting that building sensitive ACS classi-fi cation algorithms using only the 12-lead ECG is plausible.”
Self-citationOwnbey, M., Suffoletto, B. P., Frisch, A., Guyette, F. X., & Martin‐Gill, C. (2014) · Prehospital Emergency Care · doi:10.3109/10903127.2013.851310 · Cited by 15
Self-citationAl‐Zaiti, S. S., Alrawashdeh, M., Martin‐Gill, C., Callaway, C. W., Mortara, D. M., & Němec, J. (2017) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2017.08.002 · Cited by 14 · cited 1×
“We have shown that mild-to-moderate ischemia distorts the temporal – spatial features of the 12-lead ECG before ST changes evolve 8,9 , suggesting that building sensitive ACS classi-fi cation algorithms using only the 12-lead ECG is plausible.”
Self-citation
Cited by
Divergent forest sensitivity to repeated extreme droughts
Anderegg, W. R. L., Trugman, A. T., Badgley, G., Konings, A. G., & Shaw, J. (2020) · Nature Climate Change · doi:10.1038/s41558-020-00919-1 · Cited by 357
Armoundas, A. A., Narayan, S. M., Arnett, D. K., Spector-Bagdady, K., Bennett, D. A., Celi, L. A., Friedman, P. A., Gollob, M. H., Hall, J. L., Kwitek, A. E., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001201 · Cited by 347
“28 Implementation science for AI/ML is essential to ensure that personal and public data are integrated appropriately to address core unmet clinical needs to achieve precision cardiovascular medicine (Table 7).”
BackgroundSelf-citationMachine learning for ECG diagnosis and risk stratification of occlusion myocardial infarction
Al-Zaiti, S. S., Martin-Gill, C., Zègre-Hemsey, J. K., Bouzid, Z., Faramand, Z., Alrawashdeh, M. O., Gregg, R. E., Helman, S., Riek, N. T., Kraevsky-Phillips, K., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02396-3 · Cited by 309
Self-citationMachine learning for diagnosis of myocardial infarction using cardiac troponin concentrations
Doudesis, D., Lee, K. K., Boeddinghaus, J., Bularga, A., Ferry, A. V., Tuck, C., Lowry, M. T. H., Lopez-Ayala, P., Nestelberger, T., Koechlin, L., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02325-4 · Cited by 171
Herman, R., Meyers, H. P., Smith, S. W., Bertolone, D. T., Leone, A., Bermpeis, K., Viscusi, M. M., Belmonte, M., Demolder, A., Boza, V., et al. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad074 · Cited by 159
Metadata
- Authors
- Al-Zaiti, S., Besomi, L., Bouzid, Z., Faramand, Z., Frisch, S., Martin-Gill, C., Gregg, R., Saba, S., Callaway, C., & Sejdić, E.
- Venue
- Nature Communications
- Published
- 2020-08-07
- Volume
- 11
- Issue
- 1
- Pages
- 3966-3966
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3048030988
- Cited by
- 194
- References
- 40
- FWCI
- 15.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.