An enhanced isothermal amplification assay for viral detection
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Rapid, inexpensive, robust diagnostics are essential to control the spread of infectious diseases. Current state of the art diagnostics are highly sensitive and specific, but slow, and require expensive equipment. Here we report the development of a molecular diagnostic test for SARS-CoV-2 based on an enhanced recombinase polymerase amplification (eRPA) reaction. eRPA has a detection limit on patient samples down to 5 viral copies, requires minimal instrumentation, and is highly scalable and inexpensive. eRPA does not cross-react with other common coronaviruses, does not require RNA purification, and takes ~45 min from sample collection to results. eRPA represents a first step toward at-home SARS-CoV-2 detection and can be adapted to future viruses within days of genomic sequence availability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An interactive web-based dashboard to track COVID-19 in real time
Dong, E., Du, H., & Gardner, L. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30120-1 · Cited by 10,048
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805 · cited 2×
“While several creative applications of LAMP technologies to detect COVID-19, the disease caused by SARS-CoV-2, have recently been developed and show promise (14–18), RT-RPA has been less explored.”
BackgroundVirological assessment of hospitalized patients with COVID-2019
Wölfel, R., Corman, V. M., Guggemos, W., Seilmaier, M., Zange, S., Müller, M. A., Niemeyer, D., Jones, T. C., Vollmar, P., Rothe, C., et al. (2020) · Nature · doi:10.1038/s41586-020-2196-x · Cited by 6,661
Temporal dynamics in viral shedding and transmissibility of COVID-19
He, X., Lau, E. H. Y., Wu, P., Deng, X., Wang, J., Hao, X., Lau, Y. C., Wong, J. Y., Guan, Y., Tan, X., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0869-5 · Cited by 4,247 · cited 1×
“FIND is capable of reliably detecting SARS-CoV-2 virus in patient samples that contain as low as 2 viral particles/μL, and is therefore fully adequate to detect infection during the period of peak transmission (27-30, 37, 38).”
BackgroundCRISPR–Cas12-based detection of SARS-CoV-2
Broughton, J. P., Deng, X., Yu, G., Fasching, C. L., Servellita, V., Singh, J., Miao, X., Streithorst, J. A., Granados, A., Sotomayor-Gonzalez, A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0513-4 · Cited by 2,717 · cited 1×
“While several creative applications of LAMP technologies to detect COVID-19, the disease caused by SARS-CoV-2, have recently been developed and show promise (14-18), RT-RPA has been less explored.”
MethodDNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · doi:10.1101/2020.03.15.20036673 · Cited by 1,948 · cited 1×
“Because SARS-CoV-2 viral particles lyse at around 75°C (25), the period when the sample is being heated from 75°C to 85°C offers a window in which released viral RNA might be degraded during sample preparation.”
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · The Lancet Microbe · doi:10.1016/s2666-5247(20)30003-3 · Cited by 1,946
Viral load of SARS-CoV-2 in clinical samples.
Pan, Y., Zhang, D., Yang, P., Poon, L. L. M., & Wang, Q. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30113-4 · Cited by 1,562 · cited 1×
“FIND is capable of reliably detecting SARS-CoV-2 virus in patient samples that contain as low as 2 viral particles/μL, and is therefore fully adequate to detect infection during the period of peak transmission (27-30, 37, 38).”
BackgroundField-deployable viral diagnostics using CRISPR-Cas13
Myhrvold, C., Freije, C. A., Gootenberg, J. S., Abudayyeh, O. O., Metsky, H. C., Durbin, A. F., Kellner, M. J., Tan, A. L., Paul, L. M., Parham, L. A., et al. (2018) · Science · doi:10.1126/science.aas8836 · Cited by 1,444 · cited 2×
“Heat-based lysis has shown promise as a way to rapidly lyse and inactivate viruses for use in diagnostic assays (23, 24).”
BackgroundMethodZheng, S., Fan, J., Yu, F., Feng, B., Lou, B., Zou, Q., Xie, G., Lin, S., Wang, R., Yang, X., et al. (2020) · BMJ · doi:10.1136/bmj.m1443 · Cited by 1,440 · cited 1×
“FIND is capable of reliably detecting SARS-CoV-2 virus in patient samples that contain as low as 2 viral particles/μL, and is therefore fully adequate to detect infection during the period of peak transmission (27-30, 37, 38).”
BackgroundSaliva or Nasopharyngeal Swab Specimens for Detection of SARS-CoV-2
Wyllie, A. L., Fournier, J., Casanovas-Massana, A., Campbell, M., Tokuyama, M., Vijayakumar, P., Warren, J. L., Geng, B., Muenker, M. C., Moore, A. J., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2016359 · Cited by 1,169
Koczula, K. M., & Gallotta, A. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150012 · Cited by 1,147
SARS-CoV-2 (COVID-19) by the numbers
Bar-On, Y. M., Flamholz, A., Phillips, R., & Milo, R. (2020) · eLife · doi:10.7554/elife.57309 · Cited by 962
Cheng, H.-Y., Jian, S.-W., Liu, D.-P., Ng, T.-C., Huang, W.-T., Lin, H.-H., & for the Taiwan COVID-19 Outbreak Investigation Team (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.2020 · Cited by 860 · cited 1×
“FIND is capable of reliably detecting SARS-CoV-2 virus in patient samples that contain as low as 2 viral particles/μL, and is therefore fully adequate to detect infection during the period of peak transmission (27-30, 37, 38).”
BackgroundStreamlined inactivation, amplification, and Cas13-based detection of SARS-CoV-2
Arizti-Sanz, J., Freije, C. A., Stanton, A. C., Petros, B. A., Boehm, C. K., Siddiqui, S., Shaw, B. M., Adams, G., Kosoko-Thoroddsen, T.-S. F., Kemball, M. E., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19097-x · Cited by 509
Esbin, M. N., Whitney, O. N., Chong, S., Maurer, A., Darzacq, X., & Tjian, R. (2020) · RNA · doi:10.1261/rna.076232.120 · Cited by 477
Evaluation of COVID-19 RT-qPCR Test in Multi sample Pools
Yelin, I., Aharony, N., Tamar, E. S., Argoetti, A., Messer, E., Berenbaum, D., Shafran, E., Kuzli, A., Gandali, N., Shkedi, O., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa531 · Cited by 450
Pasomsub, E., Watcharananan, S. P., Boonyawat, K., Janchompoo, P., Wongtabtim, G., Suksuwan, W., Sungkanuparph, S., & Phuphuakrat, A. (2021) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2020.05.001 · Cited by 380
Rapid Molecular Detection of SARS-CoV-2 (COVID-19) Virus RNA Using Colorimetric LAMP
Zhang, Y., Odiwuor, N., Xiong, J., Sun, L., Nyaruaba, R. O., Wei, H., & Tanner, N. A. (2020) · medRxiv · doi:10.1101/2020.02.26.20028373 · Cited by 355 · cited 2×
“While several creative applications of LAMP technologies to detect COVID-19, the disease caused by SARS-CoV-2, have recently been developed and show promise (14-18), RT-RPA has been less explored.”
MethodPoint-of-care testing for COVID-19 using SHERLOCK diagnostics
Joung, J., Ladha, A., Saito, M., Segel, M., Bruneau, R., Huang, M.-L. W., Kim, N.-G., Yu, X., Li, J., Walker, B. D., et al. (2020) · doi:10.1101/2020.05.04.20091231 · Cited by 317
Self-citationSalivaDirect: A simplified and flexible platform to enhance SARS-CoV-2 testing capacity
Vogels, C. B. F., Watkins, A. E., Harden, C. A., Brackney, D. E., Shafer, J., Wang, J., Caraballo, C., Kalinich, C. C., Ott, I. M., Fauver, J. R., et al. (2021) · Med · doi:10.1016/j.medj.2020.12.010 · Cited by 306
Rabe, B. A., & Cepko, C. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2011221117 · Cited by 290
Obande, G. A., & Singh, K. K. B. (2020) · Infection and Drug Resistance · doi:10.2147/idr.s217571 · Cited by 171 · cited 2×
“Isothermal amplification technologies have long held promise to offer highly sensitive detection at high throughput, and to allow for widely distributed testing including at-home/pointof-need (PON) tests (10, 11).”
BackgroundWee, S. K., Sivalingam, S. P., & Yap, P. H. (2020) · Genes · doi:10.3390/genes11060664 · Cited by 108 · cited 1×
“storage media or dry swabs (5), and eliminating the normal RNA purification step from the standard RT-qPCR tests (6, 7).”
MethodHigh-Surety Isothermal Amplification and Detection of SARS-CoV-2
Bhadra, S., Riedel, T. E., Lakhotia, S., Tran, N., & Ellington, A. D. (2021) · mSphere · doi:10.1128/msphere.00911-20 · Cited by 98
SwabExpress: An End-to-End Protocol for Extraction-Free COVID-19 Testing
Srivatsan, S. R., Heidl, S., Pfau, B., Martin, B., Han, P. D., Zhong, W., van Raay, K., McDermot, E., Opsahl, J., Gamboa, L., et al. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab132 · Cited by 74 · cited 1×
“storage media or dry swabs (5), and eliminating the normal RNA purification step from the standard RT-qPCR tests (6, 7).”
MethodPerformance Comparison of Reverse Transcriptases for Single-Cell Studies
Žucha, D., Androvic, P., Kubista, M., & Valihrach, L. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2019.307835 · Cited by 56
Barcoded microbial system for high-resolution object provenance
Qian, J., Lu, Z., Mancuso, C. P., Jhuang, H., Barajas‐Ornelas, R. D. C., Boswell, S. A., Ramírez‐Guadiana, F. H., Jones, V., Sonti, A., Sedlack, K., et al. (2020) · Science · doi:10.1126/science.aba5584 · Cited by 50
Self-citationPreliminary support for a "dry swab, extraction free" protocol for SARS-CoV-2 testing via RT-qPCR.
Srivatsan, S. R., Han, P. D., van Raay, K., Wolf, C. R., McCulloch, D. J., Kim, A. E., Brandstetter, E., Martin, B., Gehring, J., Chen, W., et al. (2020) · eScholarship (California Digital Library) · Cited by 35
SARS-CoV-2 detection from nasopharyngeal swab samples without RNA extractionPreprint
Beltrán-Pavez, C., Márquez, C. L., Muñoz, G., Valiente‐Echeverría, F., Gaggero, A. A., Soto‐Rifo, R., & Barriga, G. P. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.03.28.013508 · Cited by 30 · cited 1×
“storage media or dry swabs (5), and eliminating the normal RNA purification step from the standard RT-qPCR tests (6, 7).”
MethodReliable and accurate diagnostics from highly multiplexed sequencing assays
Booeshaghi, A. S., Lubock, N. B., Cooper, A. R., Simpkins, S. W., Bloom, J. S., Gehring, J., Luebbert, L., Kosuri, S., & Pachter, L. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-78942-7 · Cited by 16
Different roles of histone H3 lysine 4 methylation in chromatin maintenance
Seol, J.-H., Kim, H., Yang, Y.-J., Kim, S., Youn, H., Han, J.-W., Lee, H.-W., & Cho, E. (2006) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2006.08.122 · Cited by 14 · cited 1×
“Because the N gene is expressed at up to 10-fold higher levels than the S gene in infected human cells (35), if NP swabs collect cells or cellular debris this would bias the observed N gene to S gene copy number ratio.”
BackgroundA STUDY OF RNASE ENZYMES IN SALIVA SAMPLES FROM WOMEN WITH BREAST TUMORS
Hasan, H. R., & Al-Issa, Y. A. H. (2011) · Cited by 6
Cited by
Clinical validation of a Cas13-based assay for the detection of SARS-CoV-2 RNA
Patchsung, M., Jantarug, K., Pattama, A., Aphicho, K., Suraritdechachai, S., Meesawat, P., Sappakhaw, K., Leelahakorn, N., Ruenkam, T., Wongsatit, T., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00603-x · Cited by 640
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Berhane, S., Taylor, M., Adriano, A., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub2 · Cited by 591
Streamlined inactivation, amplification, and Cas13-based detection of SARS-CoV-2
Arizti-Sanz, J., Freije, C. A., Stanton, A. C., Petros, B. A., Boehm, C. K., Siddiqui, S., Shaw, B. M., Adams, G., Kosoko-Thoroddsen, T.-S. F., Kemball, M. E., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19097-x · Cited by 509
Lu, S., Tong, X., Han, Y., Zhang, K., Zhang, Y., Chen, Q., Duan, J., Lei, X., Huang, M., Qiu, Y., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00861-x · Cited by 395
Image-based profiling for drug discovery: due for a machine-learning upgrade?
Chandrasekaran, S. N., Ceulemans, H., Boyd, J. D., & Carpenter, A. E. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-00117-w · Cited by 389
Metadata
- Authors
- Qian, J., Boswell, S. A., Chidley, C., Lu, Z.-X., Pettit, M. E., Gaudio, B. L., Fajnzylber, J. M., Ingram, R. T., Ward, R. H., Li, J. Z., & Springer, M.
- Venue
- Nature Communications
- Published
- 2020-11-20
- Volume
- 11
- Issue
- 1
- Pages
- 5920-5920
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3099840171
- Cited by
- 168
- References
- 34
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.