The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Sensing of joint and spinal bending or stretching via a retractable and wearable badge reel
Open accessAbstract
Human motions, such as joint/spinal bending or stretching, often contain information that is useful for orthopedic/neural disease diagnosis, rehabilitation, and prevention. Here, we show a badge-reel-like stretch sensing device with a grating-structured triboelectric nanogenerator exhibiting a stretching sensitivity of 8 V mm−1, a minimum resolution of 0.6 mm, a low hysteresis, and a high durability (over 120 thousand cycles). Experimental and theoretical investigations are performed to define the key features of the device. Studies from human natural daily activities and exercise demonstrate the functionality of the sensor for real-time recording of knee/arm bending, neck/waist twisting, and so on. We also used the device in a spinal laboratory, monitoring human subjects’ spine motions, and validated the measurements using the commercial inclinometer and hunchback instrument. We anticipate that the lightweight, precise and durable stretch sensor applied to spinal monitoring could help mitigate the risk of long-term abnormal postural habits induced diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329
Cited by
Cheng, T., Shao, J., & Wang, Z. L. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00220-3 · Cited by 609
Self-citationSun, Z., Zhu, M., Shan, X., & Lee, C. (2022) · Nature Communications · doi:10.1038/s41467-022-32745-8 · Cited by 532
Self-citationSelf-Powered Sensing in Wearable Electronics─A Paradigm Shift Technology
Tang, W., Sun, Q., & Wang, Z. L. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00305 · Cited by 300
Self-citationHe, L., Zhang, C., Zhang, B., Yang, O., Yuan, W., Zhou, L., Zhao, Z., Wu, Z., Wang, J., & Wang, Z. L. (2022) · ACS Nano · doi:10.1021/acsnano.1c11658 · Cited by 283
Self-citationTriboelectric nanogenerators as wearable power sources and self-powered sensors
Pu, X., Zhang, C., & Wang, Z. L. (2023) · National Science Review · doi:10.1093/nsr/nwac170 · Cited by 267
Self-citation
Metadata
- Authors
- Li, C., Liu, D., Xu, C., Wang, Z., Shu, S., Sun, Z., Tang, W., & Wang, Z. L.
- Venue
- Nature Communications
- Published
- 2021-05-19
- Volume
- 12
- Issue
- 1
- Pages
- 2950-2950
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3162774845
- Cited by
- 225
- References
- 3
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensing of joint and spinal bending or stretching via a retractable and wearable badge reel. https://app.cochat.ai/papers/10.1038/s41467-021-23207-8
- The paper
- Li, C., Liu, D., Xu, C., Wang, Z., Shu, S., Sun, Z., Tang, W., & Wang, Z. L. (2021). Sensing of joint and spinal bending or stretching via a retractable and wearable badge reel. Nature Communications. https://doi.org/10.1038/s41467-021-23207-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.