Adaptive and multifunctional hydrogel hybrid probes for long-term sensing and modulation of neural activity

Open access

Abstract

To understand the underlying mechanisms of progressive neurophysiological phenomena, neural interfaces should interact bi-directionally with brain circuits over extended periods of time. However, such interfaces remain limited by the foreign body response that stems from the chemo-mechanical mismatch between the probes and the neural tissues. To address this challenge, we developed a multifunctional sensing and actuation platform consisting of multimaterial fibers intimately integrated within a soft hydrogel matrix mimicking the brain tissue. These hybrid devices possess adaptive bending stiffness determined by the hydration states of the hydrogel matrix. This enables their direct insertion into the deep brain regions, while minimizing tissue damage associated with the brain micromotion after implantation. The hydrogel hybrid devices permit electrophysiological, optogenetic, and behavioral studies of neural circuits with minimal foreign body responses and tracking of stable isolated single neuron potentials in freely moving mice over 6 months following implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-021-23802-9

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Design, fabrication, and characterization of multifunctional hydrogel hybrid probes. a A conceptual illustration of the hydrogel hybrid probe design and its application to minimize impact on brain tissue. b, c Fabrication of the hydrogel hybrid probe including thermal drawing of the functional fiber units (b), and one-step direct polymerization of the hydrogel matrix within the fiber assembly (c). Scale bars: 50 µm. d A photograph of the optical waveguide, micro-electrode array, and microfluidic channel fibers. Scale bar: 5 cm. e A photograph of a hydrogel hybrid probe after integration of the hydrogel matrix with a multifunctional fiber assembly. Hydrogel is dyed with Rhodamine B for visual clarity. Scale bar: 1 cm. f, g Microscope images of the hydrogel hybrid probe with a fully swollen (f) and a dehydrated (g) hydrogel matrix. Scale bars: 100 µm. h Optical transmission losses of the PC/COC waveguides within the hydrogel hybrid probes at 0°, 90°, and 180° bending deformation. i Tip impedance of the electrodes within the fiber arrays in the hydrogel hybrid probes at 0° and 90° bending (paired two-sided Student’s t-test: p = 0.5232). j Return rate of the microfluidic channel fibers within the hydrogel hybrid probes at 0° and 90° bending deformation. Values in h–j represent the mean and the standard deviation (n = 6).
Fig. 1 Design, fabrication, and characterization of multifunctional hydrogel hybrid probes. a A conceptual illustration of the hydrogel hybrid probe design and its application to minimize impact on brain tissue. b, c Fabrication of the hydrogel hybrid probe including thermal drawing of the functional fiber units (b), and one-step direct polymerization of the hydrogel matrix within the fiber assembly (c). Scale bars: 50 µm. d A photograph of the optical waveguide, micro-electrode array, and microfluidic channel fibers. Scale bar: 5 cm. e A photograph of a hydrogel hybrid probe after integration of the hydrogel matrix with a multifunctional fiber assembly. Hydrogel is dyed with Rhodamine B for visual clarity. Scale bar: 1 cm. f, g Microscope images of the hydrogel hybrid probe with a fully swollen (f) and a dehydrated (g) hydrogel matrix. Scale bars: 100 µm. h Optical transmission losses of the PC/COC waveguides within the hydrogel hybrid probes at 0°, 90°, and 180° bending deformation. i Tip impedance of the electrodes within the fiber arrays in the hydrogel hybrid probes at 0° and 90° bending (paired two-sided Student’s t-test: p = 0.5232). j Return rate of the microfluidic channel fibers within the hydrogel hybrid probes at 0° and 90° bending deformation. Values in h–j represent the mean and the standard deviation (n = 6).CC BY · PubMed Central
Fig. 2 Mechanical analysis of hydrogel hybrid probes. a Mises stress profiles for fibers composed of stainless steel, silica, PC, and for the hydrogel hybrid probes under bending deformation. b Expanded view of the FEA results for a PC fiber and a hybrid probe with a fully swollen and a dehydrated hydrogel matrix. The swollen probe exhibits mechanical isolation of individual polymer fibers with discrete stress field development. c Experimentally measured bending stiffness for stainless steel, silica, and PC fibers and for the dehydrated and swollen hydrogel hybrid probes in the frequency range of 0.1–10 Hz. d, e Insertion of the hybrid probe with fully swollen (d) and dehydrated (e) hydrogel matrix into the phantom brain (0.6% agarose) at a speed of 1 mm s−1. Scale bars: 1 mm. f A conceptual illustration of the adaptive bending stiffness of the hydrogel hybrid probes. The dehydrated probes exhibit bending stiffness sufficient for initial insertion. Following implantation, probes absorb water from the surrounding tissue and convert into compliant swollen state. g A schematic illustration for the FEA model of the implanted device fixed to the skull during the brain micromotion. h Mises stress profiles within the brain tissue for stainless steel, silica, and PC fibers and for the dehydrated and swollen hydrogel hybrid probes at 100 µm lateral micromotion of the brain tissue. i The displacement for stainless steel, silica, and PC fibers and for the dehydrated and swollen hydrogel hybrid probes during 0–100 µm lateral micromotion of the brain tissue. Lines and the shaded areas in c represent the mean and the standard deviation, respectively (n = 6).
Fig. 2 Mechanical analysis of hydrogel hybrid probes. a Mises stress profiles for fibers composed of stainless steel, silica, PC, and for the hydrogel hybrid probes under bending deformation. b Expanded view of the FEA results for a PC fiber and a hybrid probe with a fully swollen and a dehydrated hydrogel matrix. The swollen probe exhibits mechanical isolation of individual polymer fibers with discrete stress field development. c Experimentally measured bending stiffness for stainless steel, silica, and PC fibers and for the dehydrated and swollen hydrogel hybrid probes in the frequency range of 0.1–10 Hz. d, e Insertion of the hybrid probe with fully swollen (d) and dehydrated (e) hydrogel matrix into the phantom brain (0.6% agarose) at a speed of 1 mm s−1. Scale bars: 1 mm. f A conceptual illustration of the adaptive bending stiffness of the hydrogel hybrid probes. The dehydrated probes exhibit bending stiffness sufficient for initial insertion. Following implantation, probes absorb water from the surrounding tissue and convert into compliant swollen state. g A schematic illustration for the FEA model of the implanted device fixed to the skull during the brain micromotion. h Mises stress profiles within the brain tissue for stainless steel, silica, and PC fibers and for the dehydrated and swollen hydrogel hybrid probes at 100 µm lateral micromotion of the brain tissue. i The displacement for stainless steel, silica, and PC fibers and for the dehydrated and swollen hydrogel hybrid probes during 0–100 µm lateral micromotion of the brain tissue. Lines and the shaded areas in c represent the mean and the standard deviation, respectively (n = 6).CC BY · PubMed Central
Fig. 3 Optogenetic interrogation by hydrogel hybrid probes. a A photograph of a mouse implanted with the hydrogel hybrid probe. Scale bar: 2 cm. b An illustration of optogenetic modulation and electrophysiological recording in the BLA-to-vHPC projection circuit. c Representative electrophysiological recordings in the vHPC during optical stimulation (10 Hz, 10 mW mm−2, 5 ms pulse width) using the hydrogel hybrid probes 3 days, 1–2 weeks, and 1–6 months following implantation and transfection with AAV5-CaMKIIα::ChR2-eYFP. d–f Amplitude of optically-evoked potentials (d) and background noise (e), and signal-to-noise ratio (SNR) (f) in the opto-electrophysiological experiments recorded from the hydrogel hybrid probes (red) and the polymer probes (blue) at various time point (n = 8 for each). g A summary of the behavioral assays performed in this study. Open field tests (OFT) are performed (3 min light OFF/ON/OFF epoch) 6 weeks following the injection of AAV5-CaMKIIα::ChR2-eYFP or AAV5-CaMKIIα::eYFP. Time spent in the center region of the OFT arena during optical stimulation (20 Hz, 10 mW mm−2, 5 ms pulse width) is analyzed for trials conducted with the injections of saline solution or glutamate receptor antagonist cocktail (NBQX + AP5). Optical stimuli and drug injections are delivered into the vHPC via the hydrogel hybrid probes. h Time spent in the center in the absence or presence of optical stimulation following injection of saline solution (two-way ANOVA and Bonferroni multiple comparison test, p = 0.0031) i Time spent in the center in the absence or presence of optical stimulation following injection glutamate receptor antagonist cocktail (two-way ANOVA and Bonferroni multiple comparison test, p > 0.9999). j–m Representative heat map images tracing the position of mice transfected with ChR2 (j, l) and eYFP (k, m) control with injection of saline solution (j, k) and glutamate receptor antagonist cocktail (l, m). Dashed line indicates the center region of the open field arena. Values in d–f, h, i represent the mean and the standard deviation (n = 8).
Fig. 3 Optogenetic interrogation by hydrogel hybrid probes. a A photograph of a mouse implanted with the hydrogel hybrid probe. Scale bar: 2 cm. b An illustration of optogenetic modulation and electrophysiological recording in the BLA-to-vHPC projection circuit. c Representative electrophysiological recordings in the vHPC during optical stimulation (10 Hz, 10 mW mm−2, 5 ms pulse width) using the hydrogel hybrid probes 3 days, 1–2 weeks, and 1–6 months following implantation and transfection with AAV5-CaMKIIα::ChR2-eYFP. d–f Amplitude of optically-evoked potentials (d) and background noise (e), and signal-to-noise ratio (SNR) (f) in the opto-electrophysiological experiments recorded from the hydrogel hybrid probes (red) and the polymer probes (blue) at various time point (n = 8 for each). g A summary of the behavioral assays performed in this study. Open field tests (OFT) are performed (3 min light OFF/ON/OFF epoch) 6 weeks following the injection of AAV5-CaMKIIα::ChR2-eYFP or AAV5-CaMKIIα::eYFP. Time spent in the center region of the OFT arena during optical stimulation (20 Hz, 10 mW mm−2, 5 ms pulse width) is analyzed for trials conducted with the injections of saline solution or glutamate receptor antagonist cocktail (NBQX + AP5). Optical stimuli and drug injections are delivered into the vHPC via the hydrogel hybrid probes. h Time spent in the center in the absence or presence of optical stimulation following injection of saline solution (two-way ANOVA and Bonferroni multiple comparison test, p = 0.0031) i Time spent in the center in the absence or presence of optical stimulation following injection glutamate receptor antagonist cocktail (two-way ANOVA and Bonferroni multiple comparison test, p > 0.9999). j–m Representative heat map images tracing the position of mice transfected with ChR2 (j, l) and eYFP (k, m) control with injection of saline solution (j, k) and glutamate receptor antagonist cocktail (l, m). Dashed line indicates the center region of the open field arena. Values in d–f, h, i represent the mean and the standard deviation (n = 8).CC BY · PubMed Central
Fig. 4 Long-term investigation of single-unit potentials and foreign body responses. a Representative spontaneous electrophysiological activity recorded in the vHPC using a hydrogel hybrid probe 1 month following implantation. b Principle component analysis of the single-unit potentials (spikes) recorded 3 days, 1 week, 2 weeks, and 1–6 months following implantation. Closed circles indicate centers and ellipses represent two standard deviations (2σ) contours of the principle component distributions. c Average spike waveforms recorded over time corresponding to clusters in b. d Average amplitude (red) and noise level (blue) of spikes in c recorded over time. e Average inter-spike intervals for each unit. Significance is confirmed by one-way Student’s t-test (***p < 0.001). f–i Average immunofluorescence area quantifying the presence of GFAP (f), Iba1 (g), CD68 (h), and IgG (i) in the vicinity of the hydrogel hybrid probes, polymer probes, and stainless steel microwires for 3 days, 1 week, 1 month, 3 months, and 6 months following implantation, respectively. Values in f–i represent the mean and the standard deviation (n = 6 for each device and time point, Kruskal–Wallis test and Dun–Sidak multiple comparison test (*p < 0.05).
Fig. 4 Long-term investigation of single-unit potentials and foreign body responses. a Representative spontaneous electrophysiological activity recorded in the vHPC using a hydrogel hybrid probe 1 month following implantation. b Principle component analysis of the single-unit potentials (spikes) recorded 3 days, 1 week, 2 weeks, and 1–6 months following implantation. Closed circles indicate centers and ellipses represent two standard deviations (2σ) contours of the principle component distributions. c Average spike waveforms recorded over time corresponding to clusters in b. d Average amplitude (red) and noise level (blue) of spikes in c recorded over time. e Average inter-spike intervals for each unit. Significance is confirmed by one-way Student’s t-test (***p < 0.001). f–i Average immunofluorescence area quantifying the presence of GFAP (f), Iba1 (g), CD68 (h), and IgG (i) in the vicinity of the hydrogel hybrid probes, polymer probes, and stainless steel microwires for 3 days, 1 week, 1 month, 3 months, and 6 months following implantation, respectively. Values in f–i represent the mean and the standard deviation (n = 6 for each device and time point, Kruskal–Wallis test and Dun–Sidak multiple comparison test (*p < 0.05).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Research works printed but not linked: 1

  1. Park, S. I. et al. Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics. Nat. Biotechnol. 33, 1280 (2015). · DOI · Paper page

Cited by

See all 334

Metadata

Authors
Park, S., Yuk, H., Zhao, R., Yim, Y. S., Woldeghebriel, E. W., Kang, J., Canales, A., Fink, Y., Choi, G. B., Zhao, X., & Anikeeva, P.
Affiliations
  • Korea Advanced Institute of Science and Technology (KR)
  • Massachusetts Institute of Technology (US)
  • The Ohio State University (US)
  • McGovern Institute for Brain Research (US)
  • Institute for Soldier Nanotechnologies (US)
Corresponding author
  • Zhao, Xuanhe
  • Anikeeva, Polina
Venue
Nature Communications
Published
2021-06-08
Volume
12
Issue
1
Pages
3435-3435
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3168009682
Cited by
312
References
46
Citations by year
2026: 42 · 2025: 74 · 2024: 72 · 2023: 67 · 2022: 41 · 2021: 16
FWCI
22.59
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
  • National Research Foundation of Korea (2020R1C1C100758911)
  • Electronics and Telecommunications Research Institute (20ZB1100)
  • United States Department of Defense | United States Army | US Army Corps of Engineers | Engineer Research and Development Center (W911NF-13-D-0001)
  • NSF | ENG/OAD | Division of Civil, Mechanical and Manufacturing Innovation (CMMI-1661627)
  • U.S. Department of Health & Human Services | NIH | National Institute of Neurological Disorders and Stroke (5R01NS086804)
  • NSF | Directorate for Mathematical & Physical Sciences | Division of Materials Research (DMR-1419807)
  • NSF | ENG/OAD | Division of Engineering Education and Centers (EEC-1028725)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
Keywords
neural interfaces, foreign body reaction, optogenetics, electrophysiological recording, multimaterial fibers, freely moving mice
MeSH terms
Action Potentials, Animals, Behavior, Animal, Biological Assay, Brain, Foreign-Body Reaction, Male, Mice, Inbred C57BL, Neurons, Stress, Mechanical, Time Factors, Molecular Probes, Biosensing Techniques, Hydrogels, Mice, Electrophysiological Phenomena, Optogenetics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive and multifunctional hydrogel hybrid probes for long-term sensing and modulation of neural activity. https://app.cochat.ai/papers/10.1038/s41467-021-23802-9
The paper
Park, S., Yuk, H., Zhao, R., Yim, Y. S., Woldeghebriel, E. W., Kang, J., Canales, A., Fink, Y., Choi, G. B., Zhao, X., & Anikeeva, P. (2021). Adaptive and multifunctional hydrogel hybrid probes for long-term sensing and modulation of neural activity. Nature Communications. https://doi.org/10.1038/s41467-021-23802-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.