Long-distance chronometric leveling with a portable optical clock
Open accessThe DOI matches its Crossref record; 60 of the 67 references it cites were found in a registry or an index; 43 of the 64 sources its claims cite were checked for support.
Abstract
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The 87Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of 3918.1(2.6) m^2 s^-2 agrees with an independent geodetic determination of 3915.88(0.30) m^2 s^-2. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of 27 cm in height.
Overview
CoChat Summary
TL;DR
The paper demonstrates long-distance chronometric leveling over 457 km by comparing two \(^{87}\)Sr optical lattice clocks via a 940-km interferometric fiber link. The chronometrically measured geopotential difference agrees with an independent GNSS/geoid determination.
Key findings
- The chronometric geopotential difference between PTB and MPQ was \(3918.1(2.6)\ \mathrm{m^2\,s^{-2}}\), agreeing with the geodetic value \(3915.88(0.30)\ \mathrm{m^2\,s^{-2}}\); the chronometric uncertainty corresponds to 27 cm in height.
- A local fractional clock offset of \(\Delta\nu_{\mathrm{loc}}/\nu_0 = 50(32)\times 10^{-18}\) was observed between the two \(^{87}\)Sr clocks, and the remote offset was \(\Delta\nu_{\mathrm{rem}}/\nu_0 = 43645(36)\times 10^{-18}\).
- The measurement achieved a height resolution below 30 cm and fractional frequency resolution of \(3\times 10^{-17}\) within one hour, and 6 cm within one day.
- Remote comparison instability was \(1.7\times 10^{-15}/\sqrt{\tau/\mathrm{s}}\), slightly higher than the local comparison instability of \(1.0\times 10^{-15}/\sqrt{\tau/\mathrm{s}}\).
Methods
- Two \(^{87}\)Sr optical lattice clocks were used: the transportable Sr2 was compared side-by-side with the stationary Sr1 at PTB before, during, and after transport to MPQ; the sites are 457 km apart with a 400 m height difference and connected by a 940-km interferometric fiber link.
- Beat notes were counted with synchronized, dead-time-free counters in phase-averaging mode at 1 s averaging; daily frequency offsets were averaged with weights \(1/u(\Delta\nu_{\mathrm{day}})^2\), accounting for correlations of systematic corrections.
- The geodetic comparison used the GNSS/geoid approach with the EGG2015 model, plus geometric leveling for small height differences between benchmarks and clocks.
Limitations
- The paper states that the significant local frequency offset between clocks operating on the same transition of the same isotope is unexpected and its reason remains unclear; the analysis assumes the offset during the remote comparison had the same value as observed locally.
- Time-variable gravity effects, mainly solid Earth and ocean tides, are stated to be below \(0.5\ \mathrm{m^2\,s^{-2}}\) maximum amplitude for the PTB–MPQ potential difference and are neglected because they largely average out over longer recording times.
- The instability is stated to be limited by the transportable clock Sr2, mainly due to Dick noise of the transportable clock laser; the paper also notes that future work aims to reduce Sr2’s systematic uncertainty to the \(10^{-18}\) level or below.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
19 Valid · 11 Not valid · 6 Not checked · 42 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The chronometrically measured geopotential difference of 3918 . 1(2 . 6) m 2 s -2 agrees with an independent geodetic determination of 3915 . 88(0 . 30) m 2 s -2 .”
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 1 · plain
“To verify our chronometric leveling result, we compare it with the result of the GNSS/geoid approach and find good agreement.”
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 4 · plain
“Its measured value is 3918 . 1(2 . 6) m 2 s -2 , which agrees with the independent, geodetic determination of 3915 . 88(0 . 30) m 2 s -2 (Fig. 3).”
What the sources say
- Partly supportedcites [23] sourceExperimental — accuracy not yet measured
Section 5 (page unavailable) reports that a comparison of optical clocks at PTB and OBSPARIS agreed with geodetic results to about 5 × 10⁻¹⁷. It does not give the cited geopotential differences of 3918.1(2.6) and 3915.88(0.30) m² s⁻² or identify the comparison result specifically as a GNSS/geoid determination. (LLM, conf=0.83)
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 1 · plain
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
What the sources say
- Not checked — no full text of the sourcecites [5] source
- Partly supportedcites [6] sourceExperimental — accuracy not yet measured
The Results (Optical link between the clocks; page unavailable) describe comparing two clocks through 1,415 km of coherent fibre links. But Methods (Instability and uncertainty contribution by the link; page unavailable) gives an overall link systematic uncertainty of <2.5 × 10−19, not sub-10−19; the Abstract reports clock-comparison uncertainty of 5 × 10−17. (LLM, conf=0.90)
- Supportedcites [7] source
The Introduction describes noise-corrected optical fiber links as a technique for comparing distant optical clocks, reporting transfer over more than 1000 km with uncertainties around 10^-20 or lower. Section 3.2 describes the interferometric frequency-comparison method. Together, these support the claimed capability over hundreds of kilometers; the claim does not require every link tested in this paper to meet that accuracy. (LLM, conf=0.88)
- Partly supportedcites [8] sourceExperimental — accuracy not yet measured
The Introduction (p. 2) says optical-fiber transmission enables comparisons of distant atomic clocks, and the Introduction (p. 3) describes a phase-stabilized link reaching telescopes 600 km apart. But this paper's experiment distributed one common clock signal, rather than comparing two independent clocks, and our copy does not establish sub-10^-19 accuracy for such a comparison. (LLM, conf=0.87)
- Not checked — no full text of the sourcecites [9] source
- Supportedcites [10] source
The Results section (‘Direct evaluation of the total link noise with ultrastable lasers’; page unavailable) reports fractional-frequency uncertainties below 10⁻¹⁹ over fibre links longer than 700 km. The paper also describes fibre-linked optical-clock comparisons in its References (page unavailable). Its own 2220 km experiment compared lasers, so the sub-10⁻¹⁹ figure is reported link performance, not the accuracy measured in that experiment. (LLM, conf=0.86)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The chronometrically measured geopotential difference of 3918 . 1(2 . 6) m 2 s -2 agrees with an independent geodetic determination of 3915 . 88(0 . 30) m 2 s -2 .”
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 4 · plain
“Its measured value is 3918 . 1(2 . 6) m 2 s -2 , which agrees with the independent, geodetic determination of 3915 . 88(0 . 30) m 2 s -2 (Fig. 3).”
What the sources say
- Partly supportedcites [23] sourceExperimental — accuracy not yet measured
Section 4.4 reports independently derived geodetic geopotential values, and the station values reproduced in Section 5 permit a difference near 3915.88 m² s⁻². Our copy does not state the claimed value or its 0.30 m² s⁻² uncertainty, so it does not substantiate the precise determination attributed to it (page numbers unavailable). (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 4 · plain
Every source the paper cites for this claim was checked and supports it.
In the paper
“Furthermore, it should be noted that existing geometric leveling data from the German height network (DHHN92) have also been used to derive the potential difference between the PTB and MPQ clock positions, resulting in a deviation to the recommended value from the GNSS/geoid approach of only 0 . 3 m 2 s -2 [23].”
What the sources say
- Supportedcites [23] source
Section 5 (page unavailable) reports that the PTB–MPQ potential difference from geometric levelling differs from the GNSS/geoid result by 0.032 m in equivalent height, approximately 0.3 m² s⁻². The paper identifies DHHN92 as the German national levelling network; the claim’s figure is a rounded expression of the reported difference. (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The main contribution is Dick noise [61] of the transportable clock laser [56].”
What the sources say
- Not matchedcites [61]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Partly supportedcites [56] sourceExperimental — accuracy not yet measured
In the introduction (page not specified), Katori says optical clocks commonly suffer Dick-effect instability and that optical-local-oscillator instability limits their stability. The paper discusses developing transportable clocks, but does not identify Dick noise from a particular transportable clock laser as the main contribution to instability. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
37 more claims · 6 with their cited sources checked
Create a free account to see all 78 claims and every source verdict.
- It may state two separate claims as one. 26
- Probably not a substantial claim. 14
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ A. Ambient BBR shift · p. 8
“We estimate the representative temperature by ( T max -T min ) / 2 and its uncertainty by ( T max -T min ) / √ 12.”
§ A. Ambient BBR shift · p. 8
“Here, it is assumed that the representative temperature that leads to the BBR shift experienced by the atoms lies with equal probability between the boundaries T max and T min [39].”
Citations
Cites
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828 · cited 1×
“This leads to the concept of physical heights that are directly related to the geopotential (a physical quantity), in contrast to the purely geometrically defined el-lipsoidal heights (distance of a point from a given reference ellipsoid) from Global Navigation Satellite Systems (GNSS) measurements…”
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“(1) and (2) in the main paper: where we have omitted the labels rem/loc for clarity.”
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“This gravitational redshift can also be understood as the change of potential energy of the photons employed to compare the clocks.”
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584 · cited 1×
“After the transportable clock was moved to MPQ, within one week ultracold 87 Sr atoms were trapped in the optical lattice and the clock transition was found.”
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543 · cited 1×
“Hence, the effect can now be utilized in geodesy to revolutionize geopotential and physical height determination capabilities.”
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507 · cited 1×
“For long-distance geodetic measurements, however, independent clocks have to be used.”
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 2×
“This leads to the concept of physical heights that are directly related to the geopotential (a physical quantity), in contrast to the purely geometrically defined el-lipsoidal heights (distance of a point from a given reference ellipsoid) from Global Navigation Satellite Systems (GNSS) measurements…”
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449 · cited 2×
“This gravitational redshift can also be understood as the change of potential energy of the photons employed to compare the clocks.”
Research works printed but not linked: 1
- M. Vermeer, 1983, Chronometric Levelling
Cited by
Coordinated international comparisons between optical clocks connected via fiber and satellite links
Lindvall, T., Pizzocaro, M., Godun, R. M., Abgrall, M., Akamatsu, D., Amy‐Klein, A., Benkler, E., Bhatt, N., Calonico, D., Cantin, E., et al. (2025) · Optica · doi:10.1364/optica.561754 · Cited by 37
“Discrepancies between Sr clocks have also been seen in other measurement campaigns [19,49] but the coordinated set of frequency ratios recorded here provides further insight.”
Self-citationNTSC SrII optical lattice clock with uncertainty of 2 × 10 − 18
Lu, X., Guo, F., Liu, Y., Cao, J., Li, J., Xia, J., Xu, Q., Lu, B., Wang, Y., & Chang, H. (2025) · Metrologia · doi:10.1088/1681-7575/addc77 · Cited by 26
GHZ protocols enhance frequency metrology despite spontaneous decay
Kielinski, T., Schmidt, P. O., & Hammerer, K. (2024) · Science Advances · doi:10.1126/sciadv.adr1439 · Cited by 33
“This unprecedented performance opens the path towards new applications in fundamental research and technology, such as the redefinition of the SI second [1], relativistic geodesy [16–19], tests of general relativity [14, 20–24] and the search for physics beyond the standard model [25–27].”
Perspective: Practical atom-based quantum sensors
Brown, J. M., & Walker, T. G. (2025) · Physical Review A · doi:10.1103/q6d1-594v · Cited by 20
Geopotential Difference Measurement Using Two Transportable Optical Clocks’ Frequency Comparisons
Liu, D., Wu, L. F., Xiong, C., & Bao, L. (2024) · Remote Sensing · doi:10.3390/rs16132462 · Cited by 12
Metadata
- Authors
- Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., Koke, S., Benkler, E., Giunta, M., Maisenbacher, L., Matveev, A., Dörscher, S., Schwarz, R., Al-Masoudi, A., Hänsch, T. W., Udem, T., Holzwarth, R., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- Max Planck Institute of Quantum Optics (DE)
- Physikalisch-Technische Bundesanstalt
- Menlo Systems (Germany) (DE)
- Max-Planck-Institut für Quantenoptik
- ORCID
- Venue
- Physical Review Applied
- Publisher
- American Physical Society (APS)
- Published
- 2024-06-03
- Volume
- 21
- Issue
- 6
- ISSN
- 2331-7019 (ISSN-L)
- OpenAlex
- W4399285623
- Cited by
- 33
- References
- 67
- Citations by year
- 2026: 8 · 2025: 18 · 2024: 6
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Physical Review Applied (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- Deutsche Forschungsgemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysics and Gravity Measurements
- Keywords
- geopotential difference, optical lattice clock, 87Sr, gravitational redshift, gravimetric analysis, height determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-distance chronometric leveling with a portable optical clock. https://app.cochat.ai/papers/10.1103/physrevapplied.21.l061001
- The paper
- Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., Koke, S., Benkler, E., Giunta, M., Maisenbacher, L., Matveev, A., Dörscher, S., Schwarz, R., Al-Masoudi, A., Hänsch, T. W., . . . Lisdat, C. (2024). Long-distance chronometric leveling with a portable optical clock. Physical Review Applied. https://doi.org/10.1103/physrevapplied.21.l061001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.