Comparing ultrastable lasers at 7 × 10−17 fractional frequency instability through a 2220 km optical fibre network
Open accessThe DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
Ultrastable lasers are essential tools in optical frequency metrology enabling unprecedented measurement precision that impacts on fields such as atomic timekeeping, tests of fundamental physics, and geodesy. To characterise an ultrastable laser it needs to be compared with a laser of similar performance, but a suitable system may not be available locally. Here, we report a comparison of two geographically separated lasers, over the longest ever reported metrological optical fibre link network, measuring 2220 km in length, at a state-of-the-art fractional-frequency instability of 7 × 10 −17 for averaging times between 30 s and 200 s. The measurements also allow the short-term instability of the complete optical fibre link network to be directly observed without using a loop-back fibre. Based on the characterisation of the noise in the lasers and optical fibre link network over different timescales, we investigate the potential for disseminating ultrastable light to improve the performance of remote optical clocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fully photonics-based coherent radar system
Ghelfi, P., Laghezza, F., Scotti, F., Serafino, G., Capria, A., Pinna, S., Onori, D., Porzi, C., Scaffardi, M., Malacarne, A., et al. (2014) · Nature · doi:10.1038/nature13078 · Cited by 1,111
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Self-citation(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · cited 1×
“This observation is important as it makes the advent of more stable lasers beneficial to the effectiveness of the clean-up oscillator scheme in two concurrent ways: (1) as just discussed it increases TRabi, reducing the atomic sensitivity to link noise, (2) it widens the separation between the frequency where the link…”
BackgroundQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationThermal-Noise Limit in the Frequency Stabilization of Lasers with Rigid Cavities
Numata, K., Kemery, A., & Camp, J. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.250602 · Cited by 554
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationDemonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Photonic microwave signals with zeptosecond-level absolute timing noise
Xie, X., Bouchand, R., Nicolodi, D., Giunta, M., Hänsel, W., Lezius, M., Joshi, A., Datta, S., Alexandre, C., Lours, M., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.215 · Cited by 441
Ultrastable laser interferometry for earthquake detection with terrestrial and submarine cables
Marra, G., Clivati, C., Luckett, R., Tampellini, A., Kronjäger, J., Wright, L., Mura, A., Levi, F., Robinson, S., Xuereb, A., et al. (2018) · Science · doi:10.1126/science.aat4458 · Cited by 407
Self-citationHigh-stability transfer of an optical frequency over long fiber-optic links
Williams, P. A., Swann, W. C., & Newbury, N. R. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001284 · Cited by 385
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385 · cited 1×
“This observation is important as it makes the advent of more stable lasers beneficial to the effectiveness of the clean-up oscillator scheme in two concurrent ways: (1) as just discussed it increases TRabi, reducing the atomic sensitivity to link noise, (2) it widens the separation between the frequency where the link…”
BackgroundSelf-citationImproved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Self-citationSantarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
Experimental quantum key distribution beyond the repeaterless secret key capacity
Minder, M., Pittaluga, M., Roberts, G. L., Lucamarini, M., Dynes, J. F., Yuan, Z. L., & Shields, A. J. (2019) · Nature Photonics · doi:10.1038/s41566-019-0377-7 · Cited by 298
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Self-citationOptical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Kerr-lens, mode-locked lasers as transfer oscillators for optical frequency measurements
Telle, H. R., Lipphardt, B., & Stenger, J. (2002) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400100735 · Cited by 242
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Self-citationPrecision Measurement of the Hydrogen1S−2SFrequency via a 920-km Fiber Link
Matveev, A., Parthey, C. G., Predehl, K., Alnis, J., Beyer, A., Holzwarth, R., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.230801 · Cited by 227
Self-citationTest of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Self-citationConsiderations on the measurement of the stability of oscillators with frequency counters
Dawkins, S. T., McFerran, J. J., & Luiten, A. N. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2007.337 · Cited by 220
Zhang, W., Martin, M. J., Benko, C., Hall, J. L., Ye, J., Hagemann, C., Legero, T., Sterr, U., Riehle, F., Cole, G. D., et al. (2014) · Optics Letters · doi:10.1364/ol.39.001980 · Cited by 184
Self-citationA strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationUltra-stable long distance optical frequency distribution using the Internet fiber network
Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.023518 · Cited by 175
Self-citationHigh-accuracy coherent optical frequency transfer over a doubled 642-km fiber link
Calonico, D., Bertacco, E. K., Calosso, C. E., Clivati, C., Costanzo, G. A., Frittelli, M., Godone, A., Mura, A., Poli, N., Sutyrin, D. V., et al. (2014) · Applied Physics B · doi:10.1007/s00340-014-5917-8 · Cited by 168
Long-distance frequency transfer over an urban fiber link using optical phase stabilization
Jiang, H., Kéfélian, F., Crane, S., Lopez, O., Lours, M., Millo, J., Holleville, D., Lemonde, P., Chardonnet, C., Amy-Klein, A., et al. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.002029 · Cited by 166
Self-citationCoherent optical clock down-conversion for microwave frequencies with 10 −18 instability
Nakamura, T., Davila-Rodriguez, J., Leopardi, H., Sherman, J. A., Fortier, T. M., Xie, X., Campbell, J. C., McGrew, W. F., Zhang, X., Hassan, Y. S., et al. (2020) · Science · doi:10.1126/science.abb2473 · Cited by 166
Quantum cascade laser frequency stabilization at the sub-Hz level
Argence, B., Chanteau, B., Lopez, O., Nicolodi, D., Abgrall, M., Chardonnet, C., Daussy, C., Darquié, B., Le Coq, Y., & Amy-Klein, A. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.93 · Cited by 162
Self-citationNew bounds on dark matter coupling from a global network of optical atomic clocks
Wcisło, P., Ablewski, P., Beloy, K., Bilicki, S., Bober, M., Brown, R., Fasano, R., Ciuryło, R., Hachisu, H., Ido, T., et al. (2018) · Science Advances · doi:10.1126/sciadv.aau4869 · Cited by 159
Self-citationDifferential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationStable Photonic Links for Frequency and Time Transfer in the Deep-Space Network and Antenna Arrays
Calhoun, M., Huang, S., & Tjoelker, R. L. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.905048 · Cited by 147
Thermal noise in optical cavities revisited
Kessler, T., Legero, T., & Sterr, U. (2012) · Journal of the Optical Society of America B · doi:10.1364/josab.29.000178 · Cited by 130
Self-citationLong-distance telecom-fiber transfer of a radio-frequency reference for radio astronomy
He, Y., Baldwin, K. G. H., Orr, B. J., Bruce Warrington, R., Wouters, M. J., Luiten, A. N., Mirtschin, P., Tzioumis, T., Phillips, C., Stevens, J., et al. (2018) · Optica · doi:10.1364/optica.5.000138 · Cited by 127
Laser frequency stabilization to a single ion
Peik, E., Schneider, T., & Tamm, C. (2006) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/39/1/012 · Cited by 125
Roberts, B. M., Delva, P., Al-Masoudi, A., Amy-Klein, A., Bærentsen, C., Baynham, C. F. A., Benkler, E., Bilicki, S., Bize, S., Bowden, W., et al. (2020) · New Journal of Physics · doi:10.1088/1367-2630/abaace · Cited by 112
Self-citationGeneration of UTC(PTB) as a fountain-clock based time scale
Bauch, A., Weyers, S., Piester, D., Staliuniene, E., & Yang, W. (2012) · Metrologia · doi:10.1088/0026-1394/49/3/180 · Cited by 104
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101
Self-citationCascaded optical fiber link using the internet network for remote clocks comparison
Chiodo, N., Quintin, N., Stefani, F., Wiotte, F., Camisard, E., Chardonnet, C., Santarelli, G., Amy-Klein, A., Pottie, P.-E., & Lopez, O. (2015) · Optics Express · doi:10.1364/oe.23.033927 · Cited by 100
Self-citationCommon-clock very long baseline interferometry using a coherent optical fiber link
Clivati, C., Aiello, R., Bianco, G., Bortolotti, C., De Natale, P., Di Sarno, V., Maddaloni, P., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Optica · doi:10.1364/optica.393356 · Cited by 99
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84
Self-citationOptical Spectrum Analyzer with Quantum-Limited Noise Floor
Bishof, M., Zhang, X., Martin, M. J., & Ye, J. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.093604 · Cited by 80
Benkler, E., Lisdat, C., & Sterr, U. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/565 · Cited by 69
Self-citationLong term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Self-citationIntercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 60
Self-citationOptical frequency transfer over submarine fiber links
Clivati, C., Tampellini, A., Mura, A., Levi, F., Marra, G., Galea, P., Xuereb, A., & Calonico, D. (2018) · Optica · doi:10.1364/optica.5.000893 · Cited by 55
Self-citationA pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Bowden, W., Hobson, R., Hill, I. R., Vianello, A., Schioppo, M., Silva, A., Margolis, H. S., Baird, P. E. G., & Gill, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-48168-3 · Cited by 55
Self-citationEnd-to-end topology for fiber comb based optical frequency transfer at the 10 −21 level
Benkler, E., Lipphardt, B., Puppe, T., Wilk, R., Rohde, F., & Sterr, U. (2019) · Optics Express · doi:10.1364/oe.27.036886 · Cited by 51
Self-citationMeasuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination
Clivati, C., Cappellini, G., Livi, L. F., Poggiali, F., de Cumis, M. S., Mancini, M., Pagano, G., Frittelli, M., Mura, A., Costanzo, G. A., et al. (2016) · Optics Express · doi:10.1364/oe.24.011865 · Cited by 48
Koke, S., Kühl, A., Waterholter, T., Raupach, S. M. F., Lopez, O., Cantin, E., Quintin, N., Amy‐Klein, A., Pottie, P.-É., & Grosche, G. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab5d95 · Cited by 37
Self-citationA low maintenance Sr optical lattice clock
Hill, I. R., Hobson, R., Bowden, W., Bridge, E. M., Donnellan, S., Curtis, E. A., & Gill, P. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012019 · Cited by 37
Self-citationMeasuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
Insero, G., Borri, S., Calonico, D., Pastor, P. C., Clivati, C., D’Ambrosio, D., Natale, P. D., Inguscio, M., Levi, F., & Santambrogio, G. (2017) · Scientific Reports · doi:10.1038/s41598-017-12891-6 · Cited by 35
A second generation of low thermal noise cryogenic silicon resonators
Matei, D. G., Legero, T., Grebing, C., Häfner, S., Lisdat, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Riehle, F., et al. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012031 · Cited by 32
Self-citationDynamical decoupling of laser phase noise in compound atomic clocks
Dörscher, S., Al-Masoudi, A., Bober, M., Schwarz, R., Hobson, R., Sterr, U., & Lisdat, C. (2020) · Communications Physics · doi:10.1038/s42005-020-00452-9 · Cited by 31
Self-citationPape, A., Terra, O., Friebe, J., Riedmann, M., Wübbena, T., Rasel, E. M., Predehl, K., Legero, T., Lipphardt, B., Schnatz, H., et al. (2010) · Optics Express · doi:10.1364/oe.18.021477 · Cited by 27
Self-citationPhase-coherent frequency comparison of optical clocks using a telecommunication fiber link
Schnatz, H., Terra, O., Predehl, K., Feldmann, T., Legero, T., Lipphardt, B., Sterr, U., Grosche, G., Holzwarth, R., Hänsch, T. W., et al. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1395 · Cited by 23
Self-citationOptical Cavities for Optical Atomic Clocks, Atom Interferometry and Gravitational-Wave Detection
Álvarez, M. D. (2019) · Springer theses · doi:10.1007/978-3-030-20863-9 · Cited by 22
Sekido, M., Takefuji, K., Ujihara, H., Kondo, T., Tsutsumi, M., Kawai, E., Hachisu, H., Nemitz, N., Pizzocaro, M., Clivati, C., et al. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01479-8 · Cited by 14
Universal formalism for data sharing and processing in clock comparison networks
Lodewyck, J., Targat, R. L., Pottie, P.-É., Benkler, E., Koke, S., & Kronjäger, J. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.043269 · Cited by 13
Self-citationDifferential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lim, H. M., et al. (2022) · doi:10.26226/m.6275705966d5dcf63a31149b · Cited by 5
Kim, M. E., McGrew, W. F., Nardelli, N. V., Clements, E., Hassan, Y. S., Zhang, X., Valencia, J. L., Leopardi, H., Hume, D. B., Fortier, T. M., et al. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2109.09540 · Cited by 3
Schioppo, M., Kronjäger, J., Silva, A., et al. (2021) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.5717954 · Cited by 1
Self-citationSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2021) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.5717953 · Cited by 1
Self-citationResolving the gravitational redshift within a millimeter atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2021) · arXiv · doi:10.48550/arxiv.2109.12238
Research works printed but not linked: 2
- Dick, J. G. Local oscillator induced instabilities in trapped ion frequency standards. In Proceedings of the 19thAnnual Precise Time and Time Interval Meeting, 133-147 (US Naval Observatory, 1988).
- Bowden W Vianello A Hill IR Schioppo M Hobson R Improving the Q factor of an optical atomic clock using quantum nondemolition measurement Phys. Rev. X 2020 10 041052
Cited by
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 211
“Conversely, optical frequency transfer over unidirectional links has demonstrated an Allan deviation of ∼ 10 − 15 at 1 s integration time, unidirectional links have demonstrated an Allan deviation of 7 × 10 − 17 for averaging times between 30 s and 200 s [82].”
BackgroundSelf-citationReview on Charge Carrier Transport in Inorganic and Organic Semiconductors
Morab, S., Minakshi, M., & Pivrikas, A. (2023) · Coatings · doi:10.3390/coatings13091657 · Cited by 117
Measuring the stability of fundamental constants with a network of clocks
Barontini, G., Blackburn, L., Boyer, V., Butuc-Mayer, F., Calmet, X., López-Urrutia, J. R. C., Curtis, E. A., Darquié, B., Dunningham, J., Fitch, N. J., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00130-5 · Cited by 95
Self-citationAnalysis of atomic-clock data to constrain variations of fundamental constants
Sherrill, N., Parsons, A. O., Baynham, C. F. A., Bowden, W., Curtis, E. A., Hendricks, R., Hill, I. R., Hobson, R., Margolis, H. S., Robertson, B., et al. (2023) · New Journal of Physics · doi:10.1088/1367-2630/aceff6 · Cited by 98
Self-citationSilicon nitride stress-optic microresonator modulator for optical control applications
Wang, J., Liu, K., Harrington, M., Rudy, R. Q., & Blumenthal, D. J. (2022) · Optics Express · doi:10.1364/oe.467721 · Cited by 79
Metadata
- Authors
- Schioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., Dovale-Álvarez, M., Williams, R. A., Marra, G., Margolis, H. S., Amy-Klein, A., Lopez, O., Cantin, E., Álvarez-Martínez, H., Le Targat, R., Pottie, P. E., Quintin, N., Legero, T., Häfner, S., Sterr, U., Schwarz, R., Dörscher, S., Lisdat, C., Koke, S., Kuhl, A., Waterholter, T., Benkler, E., & Grosche, G.
- Affiliations
- National Physical Laboratory (GB)
- Centre National de la Recherche Scientifique (FR)
- Renater (FR)
- Physikalisch-Technische Bundesanstalt (DE)
- Corresponding author
- Schioppo, M.
- Kronjäger, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2022-01-11
- Volume
- 13
- Issue
- 1
- Pages
- 212-212
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC8752831
- OpenAlex
- W4206606030
- Cited by
- 118
- References
- 69
- Citations by year
- 2026: 18 · 2025: 32 · 2024: 39 · 2023: 17 · 2022: 12
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
- Funders
- Equipex
- European Commission (18SIB05 ROCIT, HORIZON2020, 15SIB03 OC18)
- Deutsche Forschungsgemeinschaft (CRC 1227 (DQ-mat, 434617780, EXC-2123 Quantum Frontiers, 390837967, CRC 1464, CRC 1227, 274200144, (EXC 2123)
- Agence Nationale de la Recherche (ANR 10 LABX 48 01, ANR-10-LABX-0048, 15SIB03, ANR-10-IDEX-0001, 15SIB03 OC18, 10-LABX-48-01, ANR-10-LABX-48, ANR-10-IDEX, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX)
- Institut Francilien de Recherche sur les Atomes Froids
- Engineering and Physical Sciences Research Council (EP/L016524/, EP/L016524/1)
- European Metrology Programme for Innovation and Research (18SIB06 (TiFOON), 15SIB03 “OC18”, 15SIB05 “OFTEN”, 15SIB03, 15SIB05, 18SIB05 ROCIT, 18SIB05, 18SIB06)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- ultra-stable lasers, fractional frequency instability, optical frequency metrology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.