The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Pushing detectability and sensitivity for subtle force to new limits with shrinkable nanochannel structured aerogel
Open accessAbstract
There is an urgent need for developing electromechanical sensor with both ultralow detection limits and ultrahigh sensitivity to promote the progress of intelligent technology. Here we propose a strategy for fabricating a soft polysiloxane crosslinked MXene aerogel with multilevel nanochannels inside its cellular walls for ultrasensitive pressure detection. The easily shrinkable nanochannels and optimized material synergism endow the piezoresistive aerogel with an ultralow Young’s modulus (140 Pa), numerous variable conductive pathways, and mechanical robustness. This aerogel can detect extremely subtle pressure signals of 0.0063 Pa, deliver a high pressure sensitivity over 1900 kPa−1, and exhibit extraordinarily sensing robustness. These sensing properties make the MXene aerogel feasible for monitoring ultra-weak force signals arising from a human’s deep-lying internal jugular venous pulses in a non-invasive manner, detecting the dynamic impacts associated with the landing and take-off of a mosquito, and performing static pressure mapping of a hair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Self-citationUltrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Self-citationMa, Y., Liu, N., Li, L., Hu, X., Zou, Z., Wang, J., Luo, S., & Gao, Y. (2017) · Nature Communications · doi:10.1038/s41467-017-01136-9 · Cited by 788
Self-citationA stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640
Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection
Zang, Y., Zhang, F., Huang, D., Gao, X., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms7269 · Cited by 548
Cited by
Recent Advances in Flexible Pressure Sensors Based on MXene Materials
Qin, R., Nong, J., Wang, K., Liu, Y., Zhou, S., Hu, M., Zhao, H., & Shan, G. (2024) · Advanced Materials · doi:10.1002/adma.202312761 · Cited by 416
Self-citationShi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Self-citationRoy, A., Zenker, S., Jain, S., Afshari, R., Oz, Y., Zheng, Y., & Annabi, N. (2024) · Advanced Materials · doi:10.1002/adma.202404225 · Cited by 278
Yang, W., Liu, S., Wang, Z., Liu, H., Pan, C., Liu, C., & Shen, C. (2024) · Nano Energy · doi:10.1016/j.nanoen.2024.109799 · Cited by 95
Zhu, T., Wang, D., Wang, Y., Xu, F., Huang, J., Lian, M., Wang, Y., Fan, W., Miao, Y., Zhu, J., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202503693 · Cited by 32
Metadata
- Authors
- Shi, X., Fan, X., Zhu, Y., Liu, Y., Wu, P., Jiang, R., Wu, B., Wu, H.-A., Zheng, H., Wang, J., Ji, X., Chen, Y., & Liang, J.
- Venue
- Nature Communications
- Published
- 2022-03-02
- Volume
- 13
- Issue
- 1
- Pages
- 1119-1119
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4214907148
- Cited by
- 189
- References
- 13
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pushing detectability and sensitivity for subtle force to new limits with shrinkable nanochannel structured aerogel. https://app.cochat.ai/papers/10.1038/s41467-022-28760-4
- The paper
- Shi, X., Fan, X., Zhu, Y., Liu, Y., Wu, P., Jiang, R., Wu, B., Wu, H.-A., Zheng, H., Wang, J., Ji, X., Chen, Y., & Liang, J. (2022). Pushing detectability and sensitivity for subtle force to new limits with shrinkable nanochannel structured aerogel. Nature Communications. https://doi.org/10.1038/s41467-022-28760-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.