A lab-based test of the gravitational redshift with a miniature clock network

Open access

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Abstract

Einstein’s theory of general relativity predicts that a clock at a higher gravitational potential will tick faster than an otherwise identical clock at a lower potential, an effect known as the gravitational redshift. Here we perform a laboratory-based, blinded test of the gravitational redshift using differential clock comparisons within an evenly spaced array of 5 atomic ensembles spanning a height difference of 1 cm. We measure a fractional frequency gradient of [ − 12.4 ± 0. 7 (stat) ± 2. 5 (sys) ] × 10 −19 /cm, consistent with the expected redshift gradient of − 10.9 × 10 −19 /cm. Our results can also be viewed as relativistic gravitational potential difference measurements with sensitivity to mm scale changes in height on the surface of the Earth. These results highlight the potential of local-oscillator-independent differential clock comparisons for emerging applications of optical atomic clocks including geodesy, searches for new physics, gravitational wave detection, and explorations of the interplay between quantum mechanics and gravity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-023-40629-8

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Experimental system and synchronous differential clock comparisons. a A representative camera image of a spatially multiplexed array with five ensembles of 87Sr atoms (indexed 1–5 from top to bottom) trapped in a vertical 1D optical lattice for differential clock comparisons. The spacing between neighboring ensembles is 0.25 cm, spanning a total height difference of 1 cm. Due to the gravitational redshift, clocks at a higher gravitational potential are predicted to tick faster than clocks at a lower potential. The gray box shows the orientations of the applied bias magnetic field (B), and the lattice and clock laser polarizations (ϵ). b A representative outcome from synchronous Ramsey spectroscopy on the ((∣)¹S0,mF=+5/2(⟩↔((∣)³P0,mF=+3/2(⟩ clock transition with a 10 s free precession time using five atomic ensembles, resulting in ten pairwise clock comparisons. In each plot, the excitation fractions of ensemble j are plotted against the excitation fractions of ensemble i (Pj: Pi, where j > i), tracing out an ellipse which is fitted to in order to extract the frequency difference between that pair. The frequency difference is dominated by the first-order differential Zeeman shift, which is rejected when averaging transitions between opposite spin states (Supplementary Note 3A).
Fig. 1 Experimental system and synchronous differential clock comparisons. a A representative camera image of a spatially multiplexed array with five ensembles of 87Sr atoms (indexed 1–5 from top to bottom) trapped in a vertical 1D optical lattice for differential clock comparisons. The spacing between neighboring ensembles is 0.25 cm, spanning a total height difference of 1 cm. Due to the gravitational redshift, clocks at a higher gravitational potential are predicted to tick faster than clocks at a lower potential. The gray box shows the orientations of the applied bias magnetic field (B), and the lattice and clock laser polarizations (ϵ). b A representative outcome from synchronous Ramsey spectroscopy on the ((∣)¹S0,mF=+5/2(⟩↔((∣)³P0,mF=+3/2(⟩ clock transition with a 10 s free precession time using five atomic ensembles, resulting in ten pairwise clock comparisons. In each plot, the excitation fractions of ensemble j are plotted against the excitation fractions of ensemble i (Pj: Pi, where j > i), tracing out an ellipse which is fitted to in order to extract the frequency difference between that pair. The frequency difference is dominated by the first-order differential Zeeman shift, which is rejected when averaging transitions between opposite spin states (Supplementary Note 3A).CC BY · PubMed Central
Fig. 2 Sources and characterization of primary systematic shifts. The error bars correspond to 1σ standard deviation. a The differential density shift at uop = 15Erec for a symmetric pair (2, 4) is evaluated by varying the atom number difference (ΔN). A linear fit yields a shift of −0.7(1) × 10−19 per 100 atom number difference. b Evaluation of the second-order Zeeman gradient arising from the magnetic field gradient (∂B/∂z ≈ 1.5 mG/cm). A linear fit yields a gradient of −95.3(1.0) × 10−19/cm. c Characterization of the BBR shift due to thermal gradients across the vacuum chamber. The inset is an illustration of the science chamber. To evaluate the BBR effect, a thermal gradient is introduced by varying the temperature difference between top and bottom viewports by up to ±1 K. A linear fit yields a BBR sensitivity of −4.2(1) × 10−18/cm per 1 K difference in our system. d Correlations between relative trap depth difference (δu) and differential lattice light shifts after subtraction of the residual spatial light shift gradient. u and (1 + δu)u correspond to the absolute trap depths for the ensemble pairs. e Evaluation of lattice light shift gradient at uop = 15Erec after removing contributions from δu shifts. A linear fit yields a gradient of −8.0(1.1) × 10−20/Erec/cm.
Fig. 2 Sources and characterization of primary systematic shifts. The error bars correspond to 1σ standard deviation. a The differential density shift at uop = 15Erec for a symmetric pair (2, 4) is evaluated by varying the atom number difference (ΔN). A linear fit yields a shift of −0.7(1) × 10−19 per 100 atom number difference. b Evaluation of the second-order Zeeman gradient arising from the magnetic field gradient (∂B/∂z ≈ 1.5 mG/cm). A linear fit yields a gradient of −95.3(1.0) × 10−19/cm. c Characterization of the BBR shift due to thermal gradients across the vacuum chamber. The inset is an illustration of the science chamber. To evaluate the BBR effect, a thermal gradient is introduced by varying the temperature difference between top and bottom viewports by up to ±1 K. A linear fit yields a BBR sensitivity of −4.2(1) × 10−18/cm per 1 K difference in our system. d Correlations between relative trap depth difference (δu) and differential lattice light shifts after subtraction of the residual spatial light shift gradient. u and (1 + δu)u correspond to the absolute trap depths for the ensemble pairs. e Evaluation of lattice light shift gradient at uop = 15Erec after removing contributions from δu shifts. A linear fit yields a gradient of −8.0(1.1) × 10−20/Erec/cm.CC BY · PubMed Central
Fig. 3 Gravitational redshift measurements. a The measured fractional frequency gradients after accounting for all systematic corrections over 14 data taking runs (red scatter points), each of duration ranges from 1 to 4 h. The weighted average (red solid line) yields a measured gradient of [−12.4 ± 0.7(stat) ± 2.5(sys)] × 10−19/cm, consistent with the expected redshift gradient (black solid line). Red (blue) area represents ±1σ statistical (total) uncertainty, in which the statistical uncertainty is inflated by the square root of the reduced χ2 statistic, χred²=1.16. The error bars correspond to 1σ standard deviation. b Mean differential frequencies as a function of height difference across all measurements (red scatter points), analyzed using the same data set as in (a). A linear fit (red solid line) yields a fractional frequency gradient of (−11.9 ± 2.6) × 10−19/cm, again fully consistent with the expected redshift gradient (black solid line).
Fig. 3 Gravitational redshift measurements. a The measured fractional frequency gradients after accounting for all systematic corrections over 14 data taking runs (red scatter points), each of duration ranges from 1 to 4 h. The weighted average (red solid line) yields a measured gradient of [−12.4 ± 0.7(stat) ± 2.5(sys)] × 10−19/cm, consistent with the expected redshift gradient (black solid line). Red (blue) area represents ±1σ statistical (total) uncertainty, in which the statistical uncertainty is inflated by the square root of the reduced χ2 statistic, χred²=1.16. The error bars correspond to 1σ standard deviation. b Mean differential frequencies as a function of height difference across all measurements (red scatter points), analyzed using the same data set as in (a). A linear fit (red solid line) yields a fractional frequency gradient of (−11.9 ± 2.6) × 10−19/cm, again fully consistent with the expected redshift gradient (black solid line).CC BY · PubMed Central
Fig. 4 Extracting relative height differences using relativistic gravitational potential measurements. The relative clock height differences across the array are determined using the measured gravitational redshifts and the independently measured local gravitational acceleration g. The double arrows represent the extracted height difference and the associated uncertainty for each clock pair. The true clock heights are shown on the right (red values), with the lowest clock (clock 5) defined as being at a height of 0 cm. All units are in cm unless otherwise specified. The uncertainties correspond to 1σ standard deviation.
Fig. 4 Extracting relative height differences using relativistic gravitational potential measurements. The relative clock height differences across the array are determined using the measured gravitational redshifts and the independently measured local gravitational acceleration g. The double arrows represent the extracted height difference and the associated uncertainty for each clock pair. The true clock heights are shown on the right (red values), with the lowest clock (clock 5) defined as being at a height of 0 cm. All units are in cm unless otherwise specified. The uncertainties correspond to 1σ standard deviation.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 55 references

Research works printed but not linked: 5

  1. Einstein, A. Grundgedanken der allgemeinen Relativitätstheorie und Anwendung dieser Theorie in der Astronomie. Preuss. Akad. der Wissenschaften. Sitzungsberichte 315, 778–786 (1915).
  2. Huang, Y. et al. A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty. Appl. Phys. B 123, 112 (2017).
  3. Delva, P. & Lodewyck, J. Atomic clocks: new prospects in metrology and geodesy. Acta Futura 7, 67–78 (2013).
  4. Halir, R. & Flusser, J. Numerically stable direct least squares fitting of ellipses. Proc. of Sixth Intl Conf. Computer Graphics and Visualization 1 (1998).
  5. Estey, B.V.Ph. D. thesis (2016).

Cited by

See all 47

Metadata

Authors
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S.
Affiliations
University of Wisconsin–Madison (US)
Corresponding author
Kolkowitz, Shimon
Venue
Nature Communications
Published
2023-08-12
Volume
14
Issue
1
Pages
4886-4886
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4385784013
Cited by
47
References
53
Citations by year
2026: 13 · 2025: 15 · 2024: 15 · 2023: 4
FWCI
5.45
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University) (cc-by)
Funders
  • United States Department of Commerce | National Institute of Standards and Technology
  • John Templeton Foundation
  • David and Lucile Packard Foundation
  • United States Department of Defense | United States Army | U.S. Army Research, Development and Engineering Command | Army Research Office (W911NF-21-1-0012)
  • NSF | Directorate for Mathematical & Physical Sciences | Division of Physics (2143870)
  • Alfred P. Sloan Foundation
  • Northwestern University Center for Fundamental Physics Wisconsin Alumni Research Foundation
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
  • Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Pulsars and Gravitational Waves Research
Keywords
gravitational redshift, general relativity, optical atomic clocks, clock distribution, frequency gradient, geodesy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A lab-based test of the gravitational redshift with a miniature clock network. https://app.cochat.ai/papers/10.1038/s41467-023-40629-8
The paper
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023). A lab-based test of the gravitational redshift with a miniature clock network. Nature Communications. https://doi.org/10.1038/s41467-023-40629-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.