Thread-based multiplexed sensor patch for real-time sweat monitoring
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Sensor platforms that exploit the fibrous textile threads as substrates offer great promise since they can be directly sewn, woven or stitched on to any clothing. They can also be placed directly in intimate contact with the skin. In this work, we present a thread-based sensing platform in the form of a multiplexed sensing patch for continuous simultaneous on-skin monitoring of sweat. The patch performs real-time, on-body measurements of important biomarkers present in sweat such as electrolytes (sodium and ammonium ions), metabolites (lactate) and acidity (pH). Flexible threads coated with conductive inks were used as sensing electrodes. Selective potentiometric detection of electrolytes and pH was made possible through ion-selective membrane deposition and pH-sensitive polyaniline coating on threads, respectively. An amperometric enzymatic sensing scheme with lactate oxidase was used for the detection of lactate. An array of the thread sensors is integrated onto a patch with connectivity to a miniaturized circuit module containing a potentiostat, microprocessor and wireless circuitry for wireless smartphone readout. Extensive in vitro validation and an in vivo human pilot study involving a maximal exertion test show the promise of this platform for real-time physiological monitoring of human performance/fitness under stress, as well as diagnostic monitoring through sweat analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Biochemistry of exercise-induced metabolic acidosis
Robergs, R. A., Ghiasvand, F., & Parker, D. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00114.2004 · Cited by 1,304
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Smart Bandage for Monitoring and Treatment of Chronic Wounds
Mostafalu, P., Tamayol, A., Rahimi, R., Ochoa, M., Khalilpour, A., Kiaee, G., Yazdi, I. K., Bagherifard, S., Dokmeci, M. R., Ziaie, B., et al. (2018) · Small · doi:10.1002/smll.201703509 · Cited by 481
Self-citationQuantifying prion disease penetrance using large population control cohorts
Minikel, E. V., Vallabh, S. M., Lek, M., Estrada, K., Samocha, K. E., Sathirapongsasuti, J. F., McLean, C. Y., Tung, J. Y., Yu, L. P. C., Gambetti, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad5169 · Cited by 442
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Thread as a Versatile Material for Low-Cost Microfluidic Diagnostics
Li, X., Tian, J., & Shen, W. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am9006148 · Cited by 275
A Textile Dressing for Temporal and Dosage Controlled Drug Delivery
Mostafalu, P., Kiaee, G., Giatsidis, G., Khalilpour, A., Nabavinia, M., Dokmeci, M. R., Sonkusale, S., Orgill, D. P., Tamayol, A., & Khademhosseini, A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702399 · Cited by 255
Self-citationPromphet, N., Rattanawaleedirojn, P., Siralertmukul, K., Soatthiyanon, N., Potiyaraj, P., Thanawattano, C., Hinestroza, J. P., & Rodthongkum, N. (2019) · Talanta · doi:10.1016/j.talanta.2018.09.086 · Cited by 254
Mostafalu, P., Akbari, M., Alberti, K. A., Xu, Q., Khademhosseini, A., & Sonkusale, S. R. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.39 · Cited by 219
Self-citationPotentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes
Guinovart, T., Parrilla, M., Crespo, G. A., Rius, F. X., & Andrade, F. J. (2013) · The Analyst · doi:10.1039/c3an00710c · Cited by 208
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, S., Lonjaret, T., Crisp, D., Badier, J.-M., Malliaras, G. G., & Ismailova, E. (2015) · Scientific Reports · doi:10.1038/srep15003 · Cited by 195
Fluid and electrolyte needs for training, competition, and recovery
Shirreffs, S. M., & Sawka, M. N. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2011.614269 · Cited by 186
Fluid and electrolyte needs for preparation and recovery from training and competition
Shirreffs, S. M., Armstrong, L. E., & Cheuvront, S. N. (2004) · Journal of Sports Sciences · doi:10.1080/0264041031000140572 · Cited by 154
Analysis of metabolites in sweat as a measure of physical condition
Mitsubayashi, K., Suzuki, M., Tamiya, E., & Karube, I. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80004-9 · Cited by 153
Fluid and electrolyte needs for preparation and recovery from training and competition
SHIRREFFS, S. M., ARMSTRONG, L. E., & CHEUVRONT, S. N. (2004) · Food, Nutrition and Sports Performance II · doi:10.4324/9780203448618-5 · Cited by 122
Microfluidics made of yarns and knots: from fundamental properties to simple networks and operations
Safavieh, R., Zhou, G. Z., & Juncker, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20336c · Cited by 113
Exercise-associated hyponatremia and hydration status in 161-km ultramarathoners
HOFFMAN, M. D., HEW-BUTLER, T., & STUEMPFLE, K. J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827985a8 · Cited by 111
Flow control concepts for thread-based microfluidic devices
Ballerini, D. R., Li, X., & Shen, W. (2011) · Biomicrofluidics · doi:10.1063/1.3567094 · Cited by 111
Potentiometric textile-based pH sensor
Zamora, M. L., Dominguez, J. M., Trujillo, R. M., Goy, C. B., Sánchez, M. A., & Madrid, R. E. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.002 · Cited by 84
Reproducibility of an Incremental Treadmill V̇o2max Test with Gas Exchange Analysis for Runners
Lourenço, T. F., Martins, L. E. B., Tessutti, L. S., Brenzikofer, R., & de Macedo, D. V. (2011) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181e501d6 · Cited by 69
Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring
Jia, J., Xu, C., Pan, S., Xia, S., Wei, P., Noh, H. Y., Zhang, P., & Jiang, X. (2018) · Sensors · doi:10.3390/s18113775 · Cited by 69
Sweat Lactate, Ammonia, and Urea in Rugby Players
Alvear-Ordenes, I., García-López, D., De Paz, J. A., & González-Gallego, J. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830380 · Cited by 67
Hyponatremia in the 2009 161-km Western States Endurance Run
Hoffman, M. D., Stuempfle, K. J., Rogers, I. R., Weschler, L. B., & Hew-Butler, T. (2012) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.7.1.6 · Cited by 67
Jain, V., Ochoa, M., Jiang, H., Rahimi, R., & Ziaie, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0067-0 · Cited by 57
Wearable microfluidics: fabric-based digital droplet flowmetry for perspiration analysis
Yang, Y., Xing, S., Fang, Z., Li, R., Koo, H. S., & Pan, T. (2017) · Lab on a Chip · doi:10.1039/c6lc01522k · Cited by 51
Effect of carbohydrate ingestion on ammonia metabolism during exercise in humans
Snow, R. J., Carey, M. F., Stathis, C. G., Febbraio, M. A., & Hargreaves, M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.5.1576 · Cited by 47
pH sensing threads with CMOS readout for Smart Bandages
Punjiya, M., Nejad, H. R., Mostafalu, P., & Sonkusale, S. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050730 · Cited by 23
Self-citation
Cited by
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Chen, J., Yi, C., Okegbile, S. D., Cai, J., & Shen, X. (2024) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2023.3308717 · Cited by 254
Wearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208
“[116], Copyright from 2020, Nature Publishing Group.”
Background
Metadata
- Authors
- Terse-Thakoor, T., Punjiya, M., Matharu, Z., Lyu, B., Ahmad, M., Giles, G. E., Owyeung, R., Alaimo, F., Shojaei Baghini, M., Brunyé, T. T., & Sonkusale, S.
- Venue
- npj Flexible Electronics
- Published
- 2020-07-28
- Volume
- 4
- Issue
- 1
- ISSN
- 2397-4621 (ISSN-L)
- OpenAlex
- W3045646972
- Cited by
- 172
- References
- 33
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.