Microvasculature-on-a-chip for the long-term study of endothelial barrier dysfunction and microvascular obstruction in disease
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Alterations in the mechanical properties of erythrocytes occurring in inflammatory and haematological disorders such as sickle-cell disease (SCD) and malaria often lead to increased endothelial permeability, haemolysis and microvascular obstruction. However, the associations among these pathological phenomena remain unknown. Here, we show that a perfusable, endothelialized microvasculature-on-a-chip featuring an interpenetrating-polymer-network hydrogel that recapitulates the stiffness of blood vessel intima, basement membrane self-deposition and self-healing endothelial barrier function for longer than one month enables the real-time visualization, with high spatiotemporal resolution, of microvascular obstruction and endothelial permeability under physiological flow conditions. We found that extracellular haem—a haemolytic by-product—induces delayed yet reversible endothelial permeability in a dose-dependent manner, and demonstrate that endothelial interactions with SCD or malaria-infected erythrocytes cause reversible microchannel occlusion and increased in situ endothelial permeability. The microvasculature-on-a-chip enables mechanistic insight into the endothelial barrier dysfunction associated with SCD, malaria and other inflammatory and haematological diseases. An endothelialized microfluidic system that recapitulates physiological properties of the microvasculature enables the real-time visualization of vascular-pathology features associated with sickle-cell disease and malaria, with high spatiotemporal resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endothelial Function and Dysfunction: Testing and Clinical Relevance
Deanfield, J. E., Halcox, J. P., & Rabelink, T. J. (2007) · Circulation · doi:10.1161/circulationaha.106.652859 · Cited by 2,710 · cited 4×
“The Pa of BSA-AF594 of the engineered microvasculature was then calculated according to equation (1).”
InfluentialCell-laden microengineered gelatin methacrylate hydrogels
Nichol, J. W., Koshy, S. T., Bae, H., Hwang, C. M., Yamanlar, S., & Khademhosseini, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.064 · Cited by 2,377
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Signaling Mechanisms Regulating Endothelial Permeability
Mehta, D., & Malik, A. B. (2006) · Physiological Reviews · doi:10.1152/physrev.00012.2005 · Cited by 1,720 · cited 1×
“discussion We took a top-down approach and leveraged IPNs to develop a microvasculature-on-a-chip endowed with the following features that have not been reported by existing in vitro models (Supplementary Table 1): (1) it features a three-dimensional (3D) endothelial network at the microvascular size scale (20 μ m) wi…”
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I. D., McCluskey, D. K., Tan, C. K. L., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,495
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
VE-Cadherin and Endothelial Adherens Junctions: Active Guardians of Vascular Integrity
Giannotta, M., Trani, M., & Dejana, E. (2013) · Developmental Cell · doi:10.1016/j.devcel.2013.08.020 · Cited by 854
Delivery of molecular and cellular medicine to solid tumors
Jain, R. K. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.011 · Cited by 774
Schaer, D. J., Buehler, P. W., Alayash, A. I., Belcher, J. D., & Vercellotti, G. M. (2013) · Blood · doi:10.1182/blood-2012-11-451229 · Cited by 754
Belcher, J. D., Chen, C., Nguyen, J., Milbauer, L., Abdulla, F., Alayash, A. I., Smith, A., Nath, K. A., Hebbel, R. P., & Vercellotti, G. M. (2014) · Blood · doi:10.1182/blood-2013-04-495887 · Cited by 695
Cited by
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Enhancing Biopolymer Hydrogel Functionality through Interpenetrating Networks
Dhand, A. P., Galarraga, J. H., & Burdick, J. A. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.08.007 · Cited by 314
Organs-on-a-chip models for biological research
Vunjak-Novakovic, G., Ronaldson-Bouchard, K., & Radisic, M. (2021) · Cell · doi:10.1016/j.cell.2021.08.005 · Cited by 248
“recapitulating the blood vessel intima, to study the inflammatory mediators of barrier function and sickle cell occlusion (Qiu et al., 2018) (Figure 4C).”
BackgroundCardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Organ-on-a-Chip for Cancer and Immune Organs Modeling
Sun, W., Luo, Z., Lee, J., Kim, H., Lee, K., Tebon, P., Feng, Y., Dokmeci, M. R., Sengupta, S., & Khademhosseini, A. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801363 · Cited by 221
Advances in Microfluidic Blood–Brain Barrier (BBB) Models
Oddo, A., Peng, B., Tong, Z., Wei, Y., Tong, W. Y., Thissen, H., & Voelcker, N. H. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.04.006 · Cited by 221
From Arteries to Capillaries: Approaches to Engineering Human Vasculature
Fleischer, S., Tavakol, D. N., & Vunjak‐Novakovic, G. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910811 · Cited by 195
Gao, G., Park, J. Y., Kim, B. S., Jang, J., & Cho, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201801102 · Cited by 185
Engineering of Hydrogel Materials with Perfusable Microchannels for Building Vascularized Tissues
Xie, R., Zheng, W., Guan, L., Ai, Y., & Liang, Q. (2020) · Small · doi:10.1002/smll.201902838 · Cited by 167
Hydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
Modeling human HSV infection via a vascularized immune-competent skin-on-chip platform
Sun, S., Jin, L., Zheng, Y., & Zhu, J. (2022) · Nature Communications · doi:10.1038/s41467-022-33114-1 · Cited by 78
Human‐on‐Leaf‐Chip: A Biomimetic Vascular System Integrated with Chamber‐Specific Organs
Mao, M., Bei, H. P., Lam, C. H., Chen, P., Wang, S., Chen, Y., He, J., & Zhao, X. (2020) · Small · doi:10.1002/smll.202000546 · Cited by 71
Metadata
- Authors
- Qiu, Y., Ahn, B., Sakurai, Y., Hansen, C. E., Tran, R., Mimche, P. N., Mannino, R. G., Ciciliano, J. C., Lamb, T. J., Joiner, C. H., Ofori-Acquah, S. F., & Lam, W. A.
- Venue
- Nature Biomedical Engineering
- Published
- 2018-04-23
- Volume
- 2
- Issue
- 6
- Pages
- 453-463
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2800059915
- Cited by
- 187
- References
- 55
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.