The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves
Open accessAbstract
Implantable bioelectronic devices for the simulation of peripheral nerves could be used to treat disorders that are resistant to traditional pharmacological therapies. However, for many nerve targets, this requires invasive surgeries and the implantation of bulky devices (about a few centimetres in at least one dimension). Here we report the design and in vivo proof-of-concept testing of an endovascular wireless and battery-free millimetric implant for the stimulation of specific peripheral nerves that are difficult to reach via traditional surgeries. The device can be delivered through a percutaneous catheter and leverages magnetoelectric materials to receive data and power through tissue via a digitally programmable 1 mm × 0.8 mm system-on-a-chip. Implantation of the device directly on top of the sciatic nerve in rats and near a femoral artery in pigs (with a stimulation lead introduced into a blood vessel through a catheter) allowed for wireless stimulation of the animals’ sciatic and femoral nerves. Minimally invasive magnetoelectric implants may allow for the stimulation of nerves without the need for open surgery or the implantation of battery-powered pulse generators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz)
(2020) · Health Physics · doi:10.1097/hp.0000000000001210 · Cited by 2,081
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
Dong, S., Li, J.-F., & Viehland, D. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244741 · Cited by 350
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
Cited by
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
Metadata
- Authors
- Chen, J. C., Kan, P., Yu, Z., Alrashdan, F., Garcia, R., Singer, A., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., Wang, B., Felicella, M. M., Robledo, A., Peterchev, A. V., Goetz, S. M., Hartgerink, J. D., Sheth, S. A., Yang, K., & Robinson, J. T.
- Venue
- Nature Biomedical Engineering
- Published
- 2022-03-31
- Volume
- 6
- Issue
- 6
- Pages
- 706-716
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4221049448
- Cited by
- 231
- References
- 13
- FWCI
- 18.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves. https://app.cochat.ai/papers/10.1038/s41551-022-00873-7
- The paper
- Chen, J. C., Kan, P., Yu, Z., Alrashdan, F., Garcia, R., Singer, A., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., Wang, B., Felicella, M. M., Robledo, A., Peterchev, A. V., Goetz, S. M., Hartgerink, J. D., Sheth, S. A., Yang, K., & Robinson, J. T. (2022). A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-022-00873-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.