Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 231

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves

Open access
Chen, Joshua C., Kan, Peter, Yu, Zhanghao, Alrashdan, Fatima, Garcia, Roberto, Singer, Amanda, Lai, C. S. Edwin, Avants, Ben, Crosby, Scott, Li, Zhongxi, Wang, Boshuo, Felicella, Michelle M., Robledo, Ariadna, Peterchev, Angel V., Goetz, Stefan M., Hartgerink, Jeffrey D., Sheth, Sunil A., Yang, Kaiyuan, Robinson, Jacob T. · 2022 · Nature Biomedical Engineering

Abstract

Implantable bioelectronic devices for the simulation of peripheral nerves could be used to treat disorders that are resistant to traditional pharmacological therapies. However, for many nerve targets, this requires invasive surgeries and the implantation of bulky devices (about a few centimetres in at least one dimension). Here we report the design and in vivo proof-of-concept testing of an endovascular wireless and battery-free millimetric implant for the stimulation of specific peripheral nerves that are difficult to reach via traditional surgeries. The device can be delivered through a percutaneous catheter and leverages magnetoelectric materials to receive data and power through tissue via a digitally programmable 1 mm × 0.8 mm system-on-a-chip. Implantation of the device directly on top of the sciatic nerve in rats and near a femoral artery in pigs (with a stimulation lead introduced into a blood vessel through a catheter) allowed for wireless stimulation of the animals’ sciatic and femoral nerves. Minimally invasive magnetoelectric implants may allow for the stimulation of nerves without the need for open surgery or the implantation of battery-powered pulse generators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-022-00873-7

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 231

Metadata

Authors
Chen, J. C., Kan, P., Yu, Z., Alrashdan, F., Garcia, R., Singer, A., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., Wang, B., Felicella, M. M., Robledo, A., Peterchev, A. V., Goetz, S. M., Hartgerink, J. D., Sheth, S. A., Yang, K., & Robinson, J. T.
Venue
Nature Biomedical Engineering
Published
2022-03-31
Volume
6
Issue
6
Pages
706-716
ISSN
2157-846X (ISSN-L)
OpenAlex
W4221049448
Cited by
231
References
13
FWCI
18.64
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves. https://app.cochat.ai/papers/10.1038/s41551-022-00873-7
The paper
Chen, J. C., Kan, P., Yu, Z., Alrashdan, F., Garcia, R., Singer, A., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., Wang, B., Felicella, M. M., Robledo, A., Peterchev, A. V., Goetz, S. M., Hartgerink, J. D., Sheth, S. A., Yang, K., & Robinson, J. T. (2022). A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-022-00873-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.