CoChat

Ultrasensitive lateral-flow assays via plasmonically active antibody-conjugated fluorescent nanoparticles

Open access
Gupta, Rohit, Gupta, Prashant, Wang, Sean, Melnykov, Artem, Jiang, Qisheng, Seth, Anushree, Wang, Zheyu, Morrissey, Jeremiah J., George, Ige, Gandra, Sumanth, Sinha, Pratik, Storch, Gregory A., Parikh, Bijal A., Genin, Guy M., Singamaneni, Srikanth · 2023 · Nature Biomedical Engineering
Cited by 213

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Lateral-flow assays (LFAs) are rapid and inexpensive, yet they are nearly 1,000-fold less sensitive than laboratory-based tests. Here we show that plasmonically active antibody-conjugated fluorescent gold nanorods can make conventional LFAs ultrasensitive. With sample-to-answer times within 20 min, plasmonically enhanced LFAs read out via a standard benchtop fluorescence scanner attained about 30-fold improvements in dynamic range and in detection limits over 4-h-long gold-standard enzyme-linked immunosorbent assays, and achieved 95% clinical sensitivity and 100% specificity for antibodies in plasma and for antigens in nasopharyngeal swabs from individuals with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Comparable improvements in the assay’s performance can also be achieved via an inexpensive portable scanner, as we show for the detection of interleukin-6 in human serum samples and of the nucleocapsid protein of SARS-CoV-2 in nasopharyngeal samples. Plasmonically enhanced LFAs outperform standard laboratory tests in sensitivity, speed, dynamic range, ease of use and cost, and may provide advantages in point-of-care diagnostics. The sensitivity of conventional lateral-flow assays can be improved by orders of magnitude by using plasmonically active fluorescent gold nanorods as antibody-conjugated labels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-022-01001-1

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Metadata

Authors
Gupta, R., Gupta, P., Wang, S., Melnykov, A., Jiang, Q., Seth, A., Wang, Z., Morrissey, J. J., George, I., Gandra, S., Sinha, P., Storch, G. A., Parikh, B. A., Genin, G. M., & Singamaneni, S.
Venue
Nature Biomedical Engineering
Published
2023-02-02
Volume
7
Issue
12
Pages
1556-1570
ISSN
2157-846X (ISSN-L)
OpenAlex
W4318982591
Cited by
213
References
6
FWCI
15.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasensitive lateral-flow assays via plasmonically active antibody-conjugated fluorescent nanoparticles. https://app.cochat.ai/papers/10.1038/s41551-022-01001-1
The paper
Gupta, R., Gupta, P., Wang, S., Melnykov, A., Jiang, Q., Seth, A., Wang, Z., Morrissey, J. J., George, I., Gandra, S., Sinha, P., Storch, G. A., Parikh, B. A., Genin, G. M., & Singamaneni, S. (2023). Ultrasensitive lateral-flow assays via plasmonically active antibody-conjugated fluorescent nanoparticles. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-022-01001-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.