Ultrasensitive lateral-flow assays via plasmonically active antibody-conjugated fluorescent nanoparticles
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Lateral-flow assays (LFAs) are rapid and inexpensive, yet they are nearly 1,000-fold less sensitive than laboratory-based tests. Here we show that plasmonically active antibody-conjugated fluorescent gold nanorods can make conventional LFAs ultrasensitive. With sample-to-answer times within 20 min, plasmonically enhanced LFAs read out via a standard benchtop fluorescence scanner attained about 30-fold improvements in dynamic range and in detection limits over 4-h-long gold-standard enzyme-linked immunosorbent assays, and achieved 95% clinical sensitivity and 100% specificity for antibodies in plasma and for antigens in nasopharyngeal swabs from individuals with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Comparable improvements in the assay’s performance can also be achieved via an inexpensive portable scanner, as we show for the detection of interleukin-6 in human serum samples and of the nucleocapsid protein of SARS-CoV-2 in nasopharyngeal samples. Plasmonically enhanced LFAs outperform standard laboratory tests in sensitivity, speed, dynamic range, ease of use and cost, and may provide advantages in point-of-care diagnostics. The sensitivity of conventional lateral-flow assays can be improved by orders of magnitude by using plasmonically active fluorescent gold nanorods as antibody-conjugated labels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coussens, L. M., & Werb, Z. (2002) · Nature · doi:10.1038/nature01322 · Cited by 15,111 · cited 1×
“Several diseases including cancer, sepsis, human immunodeficiency virus, chronic inflammation and auto-immune diseases are known to be associated with dysregulation of the immune system, leading to disruption of the subtle balance between pro-inflammatory and anti-inflammatory cytokines 41,42 .”
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Virological assessment of hospitalized patients with COVID-2019
Wölfel, R., Corman, V. M., Guggemos, W., Seilmaier, M., Zange, S., Müller, M. A., Niemeyer, D., Jones, T. C., Vollmar, P., Rothe, C., et al. (2020) · Nature · doi:10.1038/s41586-020-2196-x · Cited by 6,661 · cited 1×
“…only when the virus is actively replicating, the antigen-based tests may have better correlation with infectiousness than RNA detection by RT–PCR. Current antigen detection tests for diagnosing COVID-19 are scalable and convenient but are limited by their low and wide-ranging accuracy 54–57 .”
The cochrane database of systematic reviews
Geddes, J. (1996) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(96)90063-x · Cited by 5,989
Jain, P. K., Lee, K. S., El-Sayed, I. H., & El-Sayed, M. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057170o · Cited by 4,603
Temporal dynamics in viral shedding and transmissibility of COVID-19
He, X., Lau, E. H. Y., Wu, P., Deng, X., Wang, J., Hao, X., Lau, Y. C., Wong, J. Y., Guan, Y., Tan, X., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0869-5 · Cited by 4,247 · cited 1×
“…proven highly successful in identifying individuals who have contracted the SARS-CoV-2 virus; however, they may fail to distinguish between infectious patients and non-infectious individuals and may yield false-positive results for months even after a patient has recovered from the disease 52,53 .”
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550 · cited 2×
“…resonance wavelength of plasmonic fluors (and the gold nanorod (AuNR) core) was tuned to match the excitation and emission wavelengths of the molecular fluorophores 27 by modifying their aspect ratios 36,37 , and the optimal Article https://doi.org/10.1038/s41551-022-01001-1 number of nanolabels.”
InfluentialAntibody responses to SARS-CoV-2 in patients with COVID-19
Long, Q.-X., Liu, B.-Z., Deng, H.-J., Wu, G.-C., Deng, K., Chen, Y.-K., Liao, P., Qiu, J.-F., Lin, Y., Cai, X.-F., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0897-1 · Cited by 2,876 · cited 2×
“A pressing need persists for sensitive, rapid and POC serological assays for SARS-CoV-2, both for epidemiological studies and for studies on vaccine efficacy against SARS-CoV-2 3,20 .”
Controlling the Synthesis and Assembly of Silver Nanostructures for Plasmonic Applications
Rycenga, M., Cobley, C. M., Zeng, J., Li, W., Moran, C. H., Zhang, Q., Qin, D., & Xia, Y. (2011) · Chemical Reviews · doi:10.1021/cr100275d · Cited by 2,828 · cited 2×
“These nanoscale constructs harness plasmon-enhanced fluorescence 28–32 to achieve nearly 7,000-fold brighter fluorescence signal compared with conventional molecular fluorophores.”
Cytokines in the pathogenesis of rheumatoid arthritis
McInnes, I. B., & Schett, G. (2007) · Nature Reviews Immunology · doi:10.1038/nri2094 · Cited by 2,529 · cited 1×
“Several diseases including cancer, sepsis, human immunodeficiency virus, chronic inflammation and auto-immune diseases are known to be associated with dysregulation of the immune system, leading to disruption of the subtle balance between pro-inflammatory and anti-inflammatory cytokines 41,42 .”
Large single-molecule fluorescence enhancements produced by a bowtie nanoantenna
Kinkhabwala, A., Yu, Z., Fan, S., Avlasevich, Y., Müllen, K., & Moerner, W. E. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.187 · Cited by 2,047
The American Journal of Tropical Medicine and Hygiene
Gifpen, H. K. (1952) · American Journal of Clinical Pathology · doi:10.1093/ajcp/22.10.992b · Cited by 1,891
Gold nanorods and their plasmonic properties
Chen, H., Shao, L., Li, Q., & Wang, J. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35367a · Cited by 1,838 · cited 2×
“36).”
InfluentialLi, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771 · cited 3×
“Several LFAs 3,4,48 and other assay methods 49 use SARS-CoV-2 spike protein as the recognition element for detection of SARS-CoV-2 antibodies.”
A serological assay to detect SARS-CoV-2 seroconversion in humans
Amanat, F., Stadlbauer, D., Strohmeier, S., Nguyen, T. H. O., Chromikova, V., McMahon, M., Jiang, K., Arunkumar, G. A., Jurczyszak, D., Polanco, J., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0913-5 · Cited by 1,769 · cited 3×
“Fluorescence was collected with a 30 mm focal length plano-convex lens (12.5 mm diameter) and passed through an 832/37 nm emission filter (Edmund Optics, 84-107).”
InfluentialDiagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754 · cited 1×
“Efforts to improve the bioanalytical performance of LFAs have included the use of fluorescent molecules or quantum dots as reporter elements 24,25 .”
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Structural Origins of High-Affinity Biotin Binding to Streptavidin
Weber, P. C., Ohlendorf, D. H., Wendoloski, J. J., & Salemme, F. R. (1989) · Science · doi:10.1126/science.2911722 · Cited by 1,223
Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Adriano, A., Berhane, S., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., Beese, S., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705 · Cited by 1,156
Clinical Microbiology and Infection
(2012) · Clinical Microbiology and Infection · doi:10.1016/s1198-743x(14)61044-2 · Cited by 1,103
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Self-citationPlasmonic Enhancement of Molecular Fluorescence
Tam, F., Goodrich, G. P., Johnson, B. R., & Halas, N. J. (2007) · Nano Letters · doi:10.1021/nl062901x · Cited by 956 · cited 1×
“These nanoscale constructs harness plasmon-enhanced fluorescence 28–32 to achieve nearly 7,000-fold brighter fluorescence signal compared with conventional molecular fluorophores.”
La Scola, B., Le Bideau, M., Andreani, J., Hoang, V. T., Grimaldier, C., Colson, P., Gautret, P., & Raoult, D. (2020) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-020-03913-9 · Cited by 811
Rethinking Covid-19 Test Sensitivity — A Strategy for Containment
Mina, M. J., Parker, R., & Larremore, D. B. (2020) · New England Journal of Medicine · doi:10.1056/nejmp2025631 · Cited by 703 · cited 1×
“…proven highly successful in identifying individuals who have contracted the SARS-CoV-2 virus; however, they may fail to distinguish between infectious patients and non-infectious individuals and may yield false-positive results for months even after a patient has recovered from the disease 52,53 .”
Quantitative Detection and Viral Load Analysis of SARS-CoV-2 in Infected Patients
Yu, F., Yan, L., Wang, N., Yang, S., Wang, L., Tang, Y., Gao, G., Wang, S., Ma, C., Xie, R., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa345 · Cited by 680 · cited 1×
“RT–PCR 16,17 and direct antigen tests 18,19 have been the mainstay for the diagnosis of COVID-19, and serological assays are important for the determination of infection stage and vaccine efficacy and for epidemiological studies 3,20,21 .”
Self-citationFluorescence Enhancement by Au Nanostructures: Nanoshells and Nanorods
Bardhan, R., Grady, N. K., Cole, J. R., Joshi, A., & Halas, N. J. (2009) · ACS Nano · doi:10.1021/nn900001q · Cited by 617
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Berhane, S., Taylor, M., Adriano, A., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub2 · Cited by 591
Pang, J., Wang, M. X., Ang, I. Y. H., Tan, S. H. X., Lewis, R. F., Chen, J. I.-P., Gutierrez, R. A., Gwee, S. X. W., Chua, P. E. Y., Yang, Q., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030623 · Cited by 553 · cited 5×
“RT–PCR 16,17 and direct antigen tests 18,19 have been the mainstay for the diagnosis of COVID-19, and serological assays are important for the determination of infection stage and vaccine efficacy and for epidemiological studies 3,20,21 .”
InfluentialHow Cytokine Networks Fuel Inflammation: Toward a cytokine-based disease taxonomy
Schett, G., Elewaut, D., McInnes, I. B., Dayer, J.-M., & Neurath, M. F. (2013) · Nature Medicine · doi:10.1038/nm.3260 · Cited by 406 · cited 1×
“Cytokines are small (5–26 kDa) proteins involved in cell signalling and immuno-modulation and are critical indicators of health and disease 40 .”
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay
Nguyen, V.-T., Song, S., Park, S., & Joo, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112015 · Cited by 373
Porte, L., Legarraga, P., Vollrath, V., Aguilera, X., Munita, J. M., Araos, R., Pizarro, G., Vial, P., Iruretagoyena, M., Dittrich, S., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.05.098 · Cited by 371 · cited 1×
“Currently, several LFA-based antigen 6,7,58 assays have been reported and are widely used, but none offers the optimal sensitivity 59 ; thus, a negative result with such assays in a symptomatic patient requires a confirmatory RT–PCR test or frequent retesting.”
Huang, C., Wen, T., Shi, F.-J., Zeng, X.-Y., & Jiao, Y.-J. (2020) · ACS Omega · doi:10.1021/acsomega.0c01554 · Cited by 350 · cited 1×
“Several LFAs 3,4,48 and other assay methods 49 use SARS-CoV-2 spike protein as the recognition element for detection of SARS-CoV-2 antibodies.”
Grant, B. D., Anderson, C. E., Williford, J. R., Alonzo, L. F., Glukhova, V. A., Boyle, D. S., Weigl, B. H., & Nichols, K. P. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01975 · Cited by 343 · cited 1×
“…of virus-specific immunoglobulins, the antibody responses to viral antigens are usually detected in the late stage of infection (7–14 days after virus exposure); therefore, serological antibody tests cannot achieve accurate screening of asymptomatic populations or early stages of infection 51 .”
Scaling up COVID-19 rapid antigen tests: promises and challenges
Peeling, R. W., Olliaro, P. L., Boeras, D. I., & Fongwen, N. (2021) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(21)00048-7 · Cited by 323 · cited 1×
“…only when the virus is actively replicating, the antigen-based tests may have better correlation with infectiousness than RNA detection by RT–PCR. Current antigen detection tests for diagnosing COVID-19 are scalable and convenient but are limited by their low and wide-ranging accuracy 54–57 .”
Antibody Tests in Detecting SARS-CoV-2 Infection: A Meta-Analysis
Kontou, P. I., Braliou, G. G., Dimou, N. L., Nikolopoulos, G., & Bagos, P. G. (2020) · Diagnostics · doi:10.3390/diagnostics10050319 · Cited by 288
Rapid Scaling Up of Covid-19 Diagnostic Testing in the United States — The NIH RADx Initiative
Tromberg, B. J., Schwetz, T. A., Pérez-Stable, E. J., Hodes, R. J., Woychik, R. P., Bright, R. A., Fleurence, R. L., & Collins, F. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmsr2022263 · Cited by 256 · cited 1×
“These limitations have precluded the millions of tests per day that are needed during epidemiological surges 22,23 .”
Soh, J. H., Chan, H.-M., & Ying, J. Y. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100831 · Cited by 230
The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays
Zhan, L., Guo, S.-Z., Song, F., Gong, Y., Xu, F., Boulware, D. R., McAlpine, M. C., Chan, W. C. W., & Bischof, J. C. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02302 · Cited by 229 · cited 2×
“34 and 35).”
Hu, J., Jiang, Y.-Z., Tang, M., Wu, L.-L., Xie, H.-Y., Zhang, Z.-L., & Pang, D.-W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05154 · Cited by 210 · cited 2×
“These considerations limit the utility of fluorescent LFAs in mass screening and resource-limited settings 10 .”
Mertens, P., De Vos, N., Martiny, D., Jassoy, C., Mirazimi, A., Cuypers, L., Van den Wijngaert, S., Monteil, V., Melin, P., Stoffels, K., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00225 · Cited by 208 · cited 1×
“Currently, several LFA-based antigen 6,7,58 assays have been reported and are widely used, but none offers the optimal sensitivity 59 ; thus, a negative result with such assays in a symptomatic patient requires a confirmatory RT–PCR test or frequent retesting.”
Hu, J., Zhang, Z.-L., Wen, C.-Y., Tang, M., Wu, L.-L., Liu, C., Zhu, L., & Pang, D.-W. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01427 · Cited by 204 · cited 1×
“Efforts to improve the bioanalytical performance of LFAs have included the use of fluorescent molecules or quantum dots as reporter elements 24,25 .”
Luan, J., Seth, A., Gupta, R., Wang, Z., Rathi, P., Cao, S., Gholami Derami, H., Tang, R., Xu, B., Achilefu, S., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0547-4 · Cited by 201 · cited 3×
“To achieve this, we used an ultrabright fluorescent nanoscale construct that we have recently introduced 27 , called plasmonic fluor, as a bimodal colorimetric and fluorescent reporter in LFAs (Fig.”
InfluentialSelf-citationCOVID-19 Point-of-Care Diagnostics: Present and Future
Valera, E., Jankelow, A., Lim, J., Kindratenko, V., Ganguli, A., White, K., Kumar, J., & Bashir, R. (2021) · ACS Nano · doi:10.1021/acsnano.1c02981 · Cited by 181 · cited 1×
“These limitations have precluded the millions of tests per day that are needed during epidemiological surges 22,23 .”
A plasmonic chip for biomarker discovery and diagnosis of type 1 diabetes
Zhang, B., Kumar, R. B., Dai, H., & Feldman, B. J. (2014) · Nature Medicine · doi:10.1038/nm.3619 · Cited by 176 · cited 1×
“30).”
Two Orders of Magnitude Improvement in Detection Limit of Lateral Flow Assays Using Isotachophoresis
Moghadam, B. Y., Connelly, K. T., & Posner, J. D. (2014) · Analytical Chemistry · doi:10.1021/ac504552r · Cited by 162 · cited 2×
“AuNPs have low capture rate ( 5%), low signal-to-background ratio and thus relatively low sensitivity 33,34 .”
Che, X.-Y., Qiu, L., Pan, Y.-X., Wen, K., Hao, W., Zhang, L.-Y., Wang, Y.-D., Liao, Z.-Y., Xu, H., Cheng, V. C., et al. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.6.2629-2635.2004 · Cited by 139 · cited 1×
“RT–PCR 16,17 and direct antigen tests 18,19 have been the mainstay for the diagnosis of COVID-19, and serological assays are important for the determination of infection stage and vaccine efficacy and for epidemiological studies 3,20,21 .”
Peterhoff, D., Glück, V., Vogel, M., Schuster, P., Schütz, A., Neubert, P., Albert, V., Frisch, S., Kiessling, M., Pervan, P., et al. (2021) · Infection · doi:10.1007/s15010-020-01503-7 · Cited by 134 · cited 1×
“RT–PCR 16,17 and direct antigen tests 18,19 have been the mainstay for the diagnosis of COVID-19, and serological assays are important for the determination of infection stage and vaccine efficacy and for epidemiological studies 3,20,21 .”
Pickering, S., Betancor, G., Galão, R. P., Merrick, B., Signell, A. W., Wilson, H. D., Kia Ik, M. T., Seow, J., Graham, C., Acors, S., et al. (2020) · PLOS Pathogens · doi:10.1371/journal.ppat.1008817 · Cited by 107
Kundu, J., Ghosh, Y., Dennis, A. M., Htoon, H., & Hollingsworth, J. A. (2012) · Nano Letters · doi:10.1021/nl3008659 · Cited by 106 · cited 1×
“Note that the Stokes shift corresponding to plasmonic fluors is much smaller (~15 nm) than those corresponding to commonly used fluorescent nanoparticles such as quantum dots and europium nanoparticles (hundreds of nano-metres) 62,63 .”
Monitoring the COVID-19 epidemic in the context of widespread local transmission
García‐Basteiro, A. L., Chaccour, C., Guinovart, C., Llupià, A., Brew, J., Trilla, A., & Plasència, A. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30162-4 · Cited by 101 · cited 1×
“10), respectively, increased, implying better signal intensity with higher The coronavirus disease 2019 (COVID-19) pandemic highlighted the need for improved LFAs for precise and rapid clinical diagnoses, mass screenings and epidemiological studies 14,15 .”
Charlton, C. L., Kanji, J. N., Johal, K., Bailey, A., Plitt, S. S., MacDonald, C., Kunst, A., Buss, E., Burnes, L. E., Fonseca, K., et al. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.01361-20 · Cited by 97 · cited 1×
“Several LFAs 3,4,48 and other assay methods 49 use SARS-CoV-2 spike protein as the recognition element for detection of SARS-CoV-2 antibodies.”
Liotti, F. M., Menchinelli, G., Lalle, E., Palucci, I., Marchetti, S., Colavita, F., Sorda, M. L., Sberna, G., Bordi, L., Sanguinetti, M., et al. (2020) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2020.09.030 · Cited by 93
Rapid and sensitive detection of interleukin-6 in serum via time-resolved lateral flow immunoassay
Huang, D., Haojun, Y., Jiang, D., Liu, F., Tian, Y., Chunlan, D., Zhang, L., & Pu, X. (2019) · Analytical Biochemistry · doi:10.1016/j.ab.2019.113468 · Cited by 88 · cited 1×
“Although few LFAs for IL-6 detection have been introduced recently 43,44 , none provides sensitivity and quantitation comparable to gold-standard ELISA.”
Lateral Flow Assay with Near-Infrared Dye for Multiplex Detection
Swanson, C., & D’Andrea, A. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.200360 · Cited by 81
Gold Nanorod Size-Dependent Fluorescence Enhancement for Ultrasensitive Fluoroimmunoassays
Liang, C., Luan, J., Wang, Z., Jiang, Q., Gupta, R., Cao, S., Liu, K., Morrissey, J. J., Kharasch, E. D., Naik, R. R., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c20303 · Cited by 58 · cited 2×
“https://doi.org/10.1038/s41551-022-01001-1 dimensions of the nanostructures were chosen to maximize fluorescence enhancement, on the basis of our previous study 38 .”
InfluentialSelf-citationMultiplexed, quantitative serological profiling of COVID-19 from blood by a point-of-care test
Heggestad, J. T., Kinnamon, D., Olson, L. B., Liu, J., Kelly, G., Wall, S. A., Oshabaheebwa, S., Quinn, Z., Fontes, C. M., Joh, D. Y., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg4901 · Cited by 53
Di, B., Hao, W., Gao, Y., Wang, M., Wang, Y.-D., Qiu, L., Wen, K., Zhou, D.-H., Wu, X.-W., Lu, E., et al. (2005) · Clinical and Vaccine Immunology · doi:10.1128/cdli.12.1.135-140.2005 · Cited by 53
Mattiuzzi, C., Henry, B. M., & Lippi, G. (2020) · Diagnosis · doi:10.1515/dx-2020-0131 · Cited by 52 · cited 1×
“Currently, several LFA-based antigen 6,7,58 assays have been reported and are widely used, but none offers the optimal sensitivity 59 ; thus, a negative result with such assays in a symptomatic patient requires a confirmatory RT–PCR test or frequent retesting.”
Krüger, L. J., Tanuri, A., Lindner, A. K., Gaeddert, M., Köppel, L., Tobian, F., Brümmer, L. E., Klein, J. A. F., Lainati, F., Schnitzler, P., et al. (2021) · EBioMedicine · doi:10.1016/j.ebiom.2021.103774 · Cited by 50
Tang, J., Wu, L., Lin, J., Zhang, E., & Luo, Y. (2021) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23752 · Cited by 33 · cited 1×
“2e, five-parameter logistic fit), which represents a 1,785-fold improvement in the LOD compared with conventional AuNP-based LFAs and at least an order of magnitude higher than the previously reported LFAs 43–46 .”
Mosley, G. L., Nguyen, P. T., Wu, B. M., & Kamei, D. T. (2016) · Lab on a Chip · doi:10.1039/c6lc00518g · Cited by 22 · cited 2×
“34 and 35).”
Fischer, P., Fischer, K., Curtis, K. C., Huang, Y., Fetcho, N., Goss, C. W., & Weil, G. J. (2021) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.20-1390 · Cited by 15
Refreshable Nanobiosensor Based on Organosilica Encapsulation of Biorecognition Elements
Gupta, R., Luan, J., Chakrabartty, S., Scheller, E. L., Morrissey, J. J., & Singamaneni, S. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17506 · Cited by 12 · cited 1×
“A plasmonic fluor consists of a plasmonically active core, a AuNR synthesized by seed-mediated method 64 , a polymer spacer layer, fluoro-phores and a universal biorecognition element (biotin).”
Self-citation
Metadata
- Authors
- Gupta, R., Gupta, P., Wang, S., Melnykov, A., Jiang, Q., Seth, A., Wang, Z., Morrissey, J. J., George, I., Gandra, S., Sinha, P., Storch, G. A., Parikh, B. A., Genin, G. M., & Singamaneni, S.
- Venue
- Nature Biomedical Engineering
- Published
- 2023-02-02
- Volume
- 7
- Issue
- 12
- Pages
- 1556-1570
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4318982591
- Cited by
- 213
- References
- 63
- FWCI
- 15.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.