CoChat

A scalable multi-photon coincidence detector based on superconducting nanowires

Open access
Zhu, Di, Zhao, Qing-Yuan, Choi, Hyeongrak, Lu, Tsung-Ju, Dane, Andrew E., Englund, Dirk, Berggren, Karl K. · 2018 · Nature Nanotechnology

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Abstract

Coincidence detection of single photons is crucial in numerous quantum technologies and usually requires multiple time-resolved single-photon detectors. However, the electronic readout becomes a major challenge when the measurement basis scales to large numbers of spatial modes. Here, we address this problem by introducing a two-terminal coincidence detector that enables scalable readout of an array of detector segments based on superconducting nanowire microstrip transmission line. Exploiting timing logic, we demonstrate a sixteen-element detector that resolves all 136 possible single-photon and two-photon coincidence events. We further explore the pulse shapes of the detector output and resolve up to four-photon events in a four-element device, giving the detector photon-number-resolving capability. This new detector architecture and operating scheme will be particularly useful for multi-photon coincidence detection in large-scale photonic integrated circuits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41565-018-0160-9

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. [S4] Q. Zhao, T. Jia, M. Gu, C. Wan, L. Zhang, W. Xu, L. Kang, J. Chen, and P. Wu, Optics Letters 39 , 1869 (2014).

Cited by

See all 87

Metadata

Authors
Zhu, D., Zhao, Q.-Y., Choi, H., Lu, T.-J., Dane, A. E., Englund, D., & Berggren, K. K.
Affiliations
Massachusetts Institute of Technology (US)
Corresponding author
Berggren, Karl K.
Venue
Nature Nanotechnology
Published
2018-06-04
Volume
13
Issue
7
Pages
596-601
ISSN
  • 1748-3387 (ISSN-L)
  • 1748-3395
OpenAlex
W2775540462
Cited by
85
References
47
Citations by year
2026: 3 · 2025: 10 · 2024: 4 · 2023: 6 · 2022: 17 · 2021: 9 · 2020: 16 · 2019: 16 · 2018: 2
FWCI
5.77
Type
journal article
Language
en
Open access
Licence
www.springer.com/tdm (tdm)
Locations
  • Nature Nanotechnology (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
  • Figshare (submittedVersion, cc-by)
  • arXiv (Cornell University)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
Keywords
superconducting nanowires, single-photon detectors, photon-number-resolving detection, photonic integrated circuits

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.