Scalable ultrasmall three-dimensional nanowire transistor probes for intracellular recording
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
New tools for intracellular electrophysiology that push the limits of spatiotemporal resolution while reducing invasiveness could provide a deeper understanding of electrogenic cells and their networks in tissues, and push progress towards human–machine interfaces. Although significant advances have been made in developing nanodevices for intracellular probes, current approaches exhibit a trade-off between device scalability and recording amplitude. We address this challenge by combining deterministic shape-controlled nanowire transfer with spatially defined semiconductor-to-metal transformation to realize scalable nanowire field-effect transistor probe arrays with controllable tip geometry and sensor size, which enable recording of up to 100 mV intracellular action potentials from primary neurons. Systematic studies on neurons and cardiomyocytes show that controlling device curvature and sensor size is critical for achieving high-amplitude intracellular recordings. In addition, this device design allows for multiplexed recording from single cells and cell networks and could enable future investigations of dynamics in the brain and other tissues. Scalable ultrasmall U-shaped nanowire FET probe arrays enable recording of full amplitude intracellular action potentials from primary neurons and other electrogenic cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Solid State Physics
Kittel, C., & Fan, H. Y. (1957) · American Journal of Physics · doi:10.1119/1.1934457 · Cited by 22,240
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Mechanisms of clathrin-mediated endocytosis
Kaksonen, M., & Roux, A. (2018) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.132 · Cited by 1,698
Chemically defined generation of human cardiomyocytes
Burridge, P. W., Matsa, E., Shukla, P., Lin, Z. C., Churko, J. M., Ebert, A. D., Lan, F., Diecke, S., Huber, B., Mordwinkin, N. M., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2999 · Cited by 1,606
Dietschy, J. M., & Turley, S. D. (2004) · Journal of Lipid Research · doi:10.1194/jlr.r400004-jlr200 · Cited by 1,095
Single-crystal metallic nanowires and metal/semiconductor nanowire heterostructures
Wu, Y., Xiang, J., Yang, C., Lu, W., & Lieber, C. M. (2004) · Nature · doi:10.1038/nature02674 · Cited by 999
Self-citationMulti-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citationPatolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.227 · Cited by 748
Self-citationNeural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Cited by
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Bioinspired bio-voltage memristors
Fu, T., Liu, X., Gao, H., Ward, J. E., Liu, X., Yin, B., Wang, Z., Zhuo, Y., Walker, D. J. F., Joshua Yang, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15759-y · Cited by 257
Liu, H., Bolonduro, O. A., Hu, N., Ju, J., Rao, A. A., Duffy, B. M., Huang, Z., Black, L. D., & Timko, B. P. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c00076 · Cited by 203
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Sasaki, M., & Goto, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-90460-8 · Cited by 5
Metadata
- Authors
- Zhao, Y., You, S. S., Zhang, A., Lee, J.-H., Huang, J., & Lieber, C. M.
- Venue
- Nature Nanotechnology
- Published
- 2019-07-01
- Volume
- 14
- Issue
- 8
- Pages
- 783-790
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2954112258
- Cited by
- 172
- References
- 40
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.