Scalable ultrasmall three-dimensional nanowire transistor probes for intracellular recording
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
New tools for intracellular electrophysiology that push the limits of spatiotemporal resolution while reducing invasiveness could provide a deeper understanding of electrogenic cells and their networks in tissues, and push progress towards human–machine interfaces. Although significant advances have been made in developing nanodevices for intracellular probes, current approaches exhibit a trade-off between device scalability and recording amplitude. We address this challenge by combining deterministic shape-controlled nanowire transfer with spatially defined semiconductor-to-metal transformation to realize scalable nanowire field-effect transistor probe arrays with controllable tip geometry and sensor size, which enable recording of up to 100 mV intracellular action potentials from primary neurons. Systematic studies on neurons and cardiomyocytes show that controlling device curvature and sensor size is critical for achieving high-amplitude intracellular recordings. In addition, this device design allows for multiplexed recording from single cells and cell networks and could enable future investigations of dynamics in the brain and other tissues. Scalable ultrasmall U-shaped nanowire FET probe arrays enable recording of full amplitude intracellular action potentials from primary neurons and other electrogenic cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Solid State Physics
Kittel, C., & Fan, H. Y. (1957) · American Journal of Physics · doi:10.1119/1.1934457 · Cited by 22,240
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Mechanisms of clathrin-mediated endocytosis
Kaksonen, M., & Roux, A. (2018) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.132 · Cited by 1,698
Chemically defined generation of human cardiomyocytes
Burridge, P. W., Matsa, E., Shukla, P., Lin, Z. C., Churko, J. M., Ebert, A. D., Lan, F., Diecke, S., Huber, B., Mordwinkin, N. M., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2999 · Cited by 1,606
Dietschy, J. M., & Turley, S. D. (2004) · Journal of Lipid Research · doi:10.1194/jlr.r400004-jlr200 · Cited by 1,095
Single-crystal metallic nanowires and metal/semiconductor nanowire heterostructures
Wu, Y., Xiang, J., Yang, C., Lu, W., & Lieber, C. M. (2004) · Nature · doi:10.1038/nature02674 · Cited by 999
Self-citationMulti-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citationPatolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.227 · Cited by 748
Self-citationNeural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Intracellular recording of action potentials by nanopillar electroporation
Xie, C., Lin, Z., Hanson, L., Cui, Y., & Cui, B. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.8 · Cited by 593
On the Origin of the Extracellular Action Potential Waveform: A Modeling Study
Gold, C., Henze, D. A., Koch, C., & Buzsáki, G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00979.2005 · Cited by 586
Molecular mechanisms of mechanotransduction in mammalian sensory neurons
Delmas, P., Hao, J., & Rodat-Despoix, L. (2011) · Nature Reviews Neuroscience · doi:10.1038/nrn2993 · Cited by 535
Functional organization of excitatory synaptic strength in primary visual cortex
Cossell, L., Iacaruso, M. F., Muir, D. R., Houlton, R., Sader, E. N., Ko, H., Hofer, S. B., & Mrsic-Flogel, T. D. (2015) · Nature · doi:10.1038/nature14182 · Cited by 527
Stable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
Self-citationNanoscale manipulation of membrane curvature for probing endocytosis in live cells
Zhao, W., Hanson, L., Lou, H.-Y., Akamatsu, M., Chowdary, P. D., Santoro, F., Marks, J. R., Grassart, A., Drubin, D. G., Cui, Y., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.98 · Cited by 302
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
Qing, Q., Jiang, Z., Xu, L., Gao, R., Mai, L., & Lieber, C. M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.273 · Cited by 257
Self-citationRational design of silicon structures for optically controlled multiscale biointerfaces
Jiang, Y., Li, X., Liu, B., Yi, J., Fang, Y., Shi, F., Gao, X., Sudzilovsky, E., Parameswaran, R., Koehler, K., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0230-1 · Cited by 254
Photoelectrochemical modulation of neuronal activity with free-standing coaxial silicon nanowires
Parameswaran, R., Carvalho-de-Souza, J. L., Jiang, Y., Burke, M. J., Zimmerman, J. F., Koehler, K., Phillips, A. W., Yi, J., Adams, E. J., Bezanilla, F., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-017-0041-7 · Cited by 239
Dipalo, M., Amin, H., Lovato, L., Moia, F., Caprettini, V., Messina, G. C., Tantussi, F., Berdondini, L., & De Angelis, F. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b01523 · Cited by 228
Study, R. E., & Kral, M. G. (1996) · Pain · doi:10.1016/0304-3959(95)00216-2 · Cited by 208
Cardiomyocytes structure, function and associated pathologies
Woodcock, E. A., & Matkovich, S. J. (2005) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2005.04.011 · Cited by 191
A method for single-neuron chronic recording from the retina in awake mice
Hong, G., Fu, T.-M., Qiao, M., Viveros, R. D., Yang, X., Zhou, T., Lee, J. M., Park, H.-G., Sanes, J. R., & Lieber, C. M. (2018) · Science · doi:10.1126/science.aas9160 · Cited by 172
Self-citationElectrodiffusion phenomena in neuroscience: a neglected companion
Savtchenko, L. P., Poo, M. M., & Rusakov, D. A. (2017) · Nature reviews. Neuroscience · doi:10.1038/nrn.2017.101 · Cited by 131
Optimizing Nanoelectrode Arrays for Scalable Intracellular Electrophysiology
Abbott, J., Ye, T., Ham, D., & Park, H. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00519 · Cited by 122
Dipalo, M., Melle, G., Lovato, L., Jacassi, A., Santoro, F., Caprettini, V., Schirato, A., Alabastri, A., Garoli, D., Bruno, G., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0222-z · Cited by 110
Spontaneous Internalization of Cell Penetrating Peptide-Modified Nanowires into Primary Neurons
Lee, J.-H., Zhang, A., You, S. S., & Lieber, C. M. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00020 · Cited by 101
Self-citationAtomic gold–enabled three-dimensional lithography for silicon mesostructures
Luo, Z., Jiang, Y., Myers, B. D., Isheim, D., Wu, J., Zimmerman, J. F., Wang, Z., Li, Q., Wang, Y., Chen, X., et al. (2015) · Science · doi:10.1126/science.1257278 · Cited by 92
Membrane curvature bends the laws of physics and chemistry
Iversen, L., Mathiasen, S., Larsen, J. B., & Stamou, D. G. (2015) · Nature Chemical Biology · doi:10.1038/nchembio.1941 · Cited by 91
Cells Adhering to 3D Vertical Nanostructures: Cell Membrane Reshaping without Stable Internalization
Dipalo, M., McGuire, A. F., Lou, H.-Y., Caprettini, V., Melle, G., Bruno, G., Lubrano, C., Matino, L., Li, X., Angelis, F. D., et al. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b03163 · Cited by 87
Interfacing Cells with Vertical Nanoscale Devices: Applications and Characterization
McGuire, A. F., Santoro, F., & Cui, B. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125705 · Cited by 84
Shmoel, N., Rabieh, N., Ojovan, S. M., Erez, H., Maydan, E., & Spira, M. E. (2016) · Scientific Reports · doi:10.1038/srep27110 · Cited by 78
Beyond the Patch Clamp: Nanotechnologies for Intracellular Recording
Kruskal, P. B., Jiang, Z., Gao, T., & Lieber, C. M. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.004 · Cited by 64
Self-citationShape-Controlled Deterministic Assembly of Nanowires
Zhao, Y., Yao, J., Xu, L., Mankin, M. N., Zhu, Y., Wu, H., Mai, L., Zhang, Q., & Lieber, C. M. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00292 · Cited by 62
Self-citationZhu, H., Scharnhorst, K. S., Stieg, A. Z., Gimzewski, J. K., Minami, I., Nakatsuji, N., Nakano, H., & Nakano, A. (2017) · Scientific Reports · doi:10.1038/srep43210 · Cited by 55
Patch-Clamp Methods and Protocols
(2014) · Methods in molecular biology · doi:10.1007/978-1-4939-1096-0 · Cited by 50
Multisite Attenuated Intracellular Recordings by Extracellular Multielectrode Arrays, a Perspective
Spira, M. E., Shmoel, N., Huang, S.-H., & Erez, H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00212 · Cited by 48
Plasma Membrane and Actin Cytoskeleton as Synergistic Barriers to Nanowire Cell Penetration
Aalipour, A., Xu, A. M., Leal‐Ortiz, S., Garner, C. C., & Melosh, N. A. (2014) · Langmuir · doi:10.1021/la502273f · Cited by 48
Problems with extracellular recording of electrical activity in gastrointestinal muscle
Sanders, K. M., Ward, S. M., & Hennig, G. W. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2016.161 · Cited by 41
Cited by
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Bioinspired bio-voltage memristors
Fu, T., Liu, X., Gao, H., Ward, J. E., Liu, X., Yin, B., Wang, Z., Zhuo, Y., Walker, D. J. F., Joshua Yang, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15759-y · Cited by 257
Liu, H., Bolonduro, O. A., Hu, N., Ju, J., Rao, A. A., Duffy, B. M., Huang, Z., Black, L. D., & Timko, B. P. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c00076 · Cited by 203
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Sasaki, M., & Goto, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-90460-8 · Cited by 5
Metadata
- Authors
- Zhao, Y., You, S. S., Zhang, A., Lee, J.-H., Huang, J., & Lieber, C. M.
- Venue
- Nature Nanotechnology
- Published
- 2019-07-01
- Volume
- 14
- Issue
- 8
- Pages
- 783-790
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2954112258
- Cited by
- 172
- References
- 40
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.