Electron ptychography of 2D materials to deep sub-ångström resolution
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Aberration-corrected optics have made electron microscopy at atomic resolution a widespread and often essential tool for characterizing nanoscale structures. Image resolution has traditionally been improved by increasing the numerical aperture of the lens (α) and the beam energy, with the state-of-the-art at 300 kiloelectronvolts just entering the deep sub-ångström (that is, less than 0.5 ångström) regime. Two-dimensional (2D) materials are imaged at lower beam energies to avoid displacement damage from large momenta transfers, limiting spatial resolution to about 1 ångström. Here, by combining an electron microscope pixel-array detector with the dynamic range necessary to record the complete distribution of transmitted electrons and full-field ptychography to recover phase information from the full phase space, we increase the spatial resolution well beyond the traditional numerical-aperture-limited resolution. At a beam energy of 80 kiloelectronvolts, our ptychographic reconstruction improves the image contrast of single-atom defects in MoS2 substantially, reaching an information limit close to 5α, which corresponds to an Abbe diffraction-limited resolution of 0.39 ångström, at the electron dose and imaging conditions for which conventional imaging methods reach only 0.98 ångström. Combining an electron microscope pixel-array detector that collects the entire distribution of scattered electrons with full-field ptychography greatly improves image resolution and contrast compared to traditional techniques, even at low beam energies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548
Grains and grain boundaries in single-layer graphene atomic patchwork quilts
Huang, P. Y., Ruiz-Vargas, C. S., van der Zande, A. M., Whitney, W. S., Levendorf, M. P., Kevek, J. W., Garg, S., Alden, J. S., Hustedt, C. J., Zhu, Y., et al. (2011) · Nature · doi:10.1038/nature09718 · Cited by 2,013
Self-citationAn improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496
Atom-by-atom structural and chemical analysis by annular dark-field electron microscopy
Krivanek, O. L., Chisholm, M. F., Nicolosi, V., Pennycook, T. J., Corbin, G. J., Dellby, N., Murfitt, M. F., Own, C. S., Szilagyi, Z. S., Oxley, M. P., et al. (2010) · Nature · doi:10.1038/nature08879 · Cited by 1,352
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Henderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194
Electron microscopy image enhanced
Haider, M., Uhlemann, S., Schwan, E., Rose, H., Kabius, B., & Urban, K. (1998) · Nature · doi:10.1038/33823 · Cited by 1,057
Hard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
New analytical scattering-factor functions for free atoms and ions
Waasmaier, D., & Kirfel, A. (1995) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767394013292 · Cited by 643
Atomic-Resolution Imaging with a Sub-50-pm Electron Probe
Erni, R., Rossell, M. D., Kisielowski, C., & Dahmen, U. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.096101 · Cited by 562
Imaging and dynamics of light atoms and molecules on graphene
Meyer, J. C., Girit, C. O., Crommie, M. F., & Zettl, A. (2008) · Nature · doi:10.1038/nature07094 · Cited by 517
High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy
Täte, M. W., Purohit, P., Chamberlain, D., Nguyen, K. X., Hovden, R., Chang, C. S., Deb, P., Turgut, E., Heron, J. T., Schlom, D. G., et al. (2016) · Microscopy and Microanalysis · doi:10.1017/s1431927615015664 · Cited by 498
Self-citationAccurate Measurement of Electron Beam Induced Displacement Cross Sections for Single-Layer Graphene
Meyer, J. C., Eder, F., Kurasch, S., Skakalova, V., Kotakoski, J., Park, H. J., Roth, S., Chuvilin, A., Eyhusen, S., Benner, G., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.196102 · Cited by 455
Further improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
Rose, A., & Biberman, L. (1975) · Physics Today · doi:10.1063/1.3069240 · Cited by 378
Tailoring the Electronic Structure in Bilayer Molybdenum Disulfide via Interlayer Twist
van der Zande, A. M., Kunstmann, J., Chernikov, A., Chenet, D. A., You, Y., Zhang, X., Huang, P. Y., Berkelbach, T. C., Wang, L., Zhang, F., et al. (2014) · Nano Letters · doi:10.1021/nl501077m · Cited by 329
Self-citationSuperresolution imaging via ptychography
Maiden, A. M., Humphry, M. J., Zhang, F., & Rodenburg, J. M. (2011) · Journal of the Optical Society of America A · doi:10.1364/josaa.28.000604 · Cited by 256
Rose, A. (1970) · Applied Solid State Physics · doi:10.1007/978-1-4684-1854-5_4 · Cited by 251
Modelling the inelastic scattering of fast electrons
Allen, L. J., D׳Alfonso, A. J., & Findlay, S. D. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2014.10.011 · Cited by 217
Transmission electron microscopy at 20kV for imaging and spectroscopy
Kaiser, U., Biskupek, J., Meyer, J. C., Leschner, J., Lechner, L., Rose, H., Stöger-Pollach, M., Khlobystov, A. N., Hartel, P., Müller, H., et al. (2011) · Ultramicroscopy · doi:10.1016/j.ultramic.2011.03.012 · Cited by 202
Sawada, H., Tanishiro, Y., Ohashi, N., Tomita, T., Hosokawa, F., Kaneyama, T., Kondo, Y., & Takayanagi, K. (2009) · Journal of Electron Microscopy · doi:10.1093/jmicro/dfp030 · Cited by 170
Wave-front phase retrieval in transmission electron microscopy via ptychography
Hue, F., Rodenburg, J. M., Maiden, A., Sweeney, F., & Midgley, P. A. (2010) · Physical Review B · doi:10.1103/physrevb.82.121415 · Cited by 117
Spherical aberration and the information content of optical images
Black, G., & Linfoot, E. H. (1957) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1957.0059 · Cited by 106
Cited by
Sun, L., Yuan, G., Gao, L., Yang, J., Chhowalla, M., Gharahcheshmeh, M. H., Gleason, K. K., Choi, Y. S., Hong, B. H., & Liu, Z. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-020-00005-y · Cited by 793
Metrology for the next generation of semiconductor devices
Orji, N. G., Badaroglu, M., Barnes, B. M., Beitia, C., Bunday, B. D., Celano, U., Kline, R. J., Neisser, M., Obeng, Y., & Vladar, A. E. (2018) · Nature Electronics · doi:10.1038/s41928-018-0150-9 · Cited by 501
Radiation damage to organic and inorganic specimens in the TEM
Egerton, R. F. (2019) · Micron · doi:10.1016/j.micron.2019.01.005 · Cited by 450
Operando Methods in Electrocatalysis
Yang, Y., Xiong, Y., Zeng, R., Lu, X., Krumov, M., Huang, X., Xu, W., Wang, H., DiSalvo, F. J., Brock, J. D., et al. (2021) · ACS Catalysis · doi:10.1021/acscatal.0c04789 · Cited by 274
Self-citationStrain fields in twisted bilayer graphene
Kazmierczak, N. P., Van Winkle, M., Ophus, C., Bustillo, K. C., Carr, S., Brown, H. G., Ciston, J., Taniguchi, T., Watanabe, K., & Bediako, D. K. (2021) · Nature Materials · doi:10.1038/s41563-021-00973-w · Cited by 268
Metadata
- Authors
- Jiang, Y., Chen, Z., Han, Y., Deb, P., Gao, H., Xie, S., Purohit, P., Tate, M. W., Park, J., Gruner, S. M., Elser, V., & Muller, D. A.
- Venue
- Nature
- Published
- 2018-07
- Volume
- 559
- Issue
- 7714
- Pages
- 343-349
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2835210520
- Cited by
- 664
- References
- 23
- FWCI
- 31.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.